Residual gentamicin-release from antibiotic-loaded polymethylmethacrylate beads after 5 years of implantation
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterial-Centered Infection: Microbial Adhesion Versus Tissue Integration
Gristina, A. G. (1987) · Science · doi:10.1126/science.3629258 · Cited by 2,156 · cited 1×
“Any biomaterial left in the human body must be considered as a potential focus for infection [ 9 ].”
Biomaterial-associated infection of gentamicin-loaded PMMA beads in orthopaedic revision surgery
Neut, D. (2001) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/47.6.885 · Cited by 296 · cited 2×
“Residual gentamicin release was established using fluorescence polarization immunoassay and extensive microbiological culturing of the retrieved beads [5] was done to isolate infecting bacterial strains.”
Self-citationKLEMM, K. W. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199310000-00011 · Cited by 194 · cited 1×
“the explanted beads, that were identified as gentamicinresistant coagulase-negative staphylococci, CNS with a MIC equal to 10mg/ml, well above the limit for gentamicin resistance, i.e. 4mg/ml [ 8 ].”
Walenkamp, G. H. I. M., Vree, T. B., & Rens, T. J. G. V. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198604000-00021 · Cited by 97 · cited 1×
“Patients are treated with gentamicin-loaded beads during approximately 14 days, after which 20–70% of the total amount of gentamicin incorporated in the beads is released into the body and gentamicin concentrations dropgreatly [ 2 ].”
ELUTION CHARACTERISTICS OF GENTAMICIN-PMMA BEADS AFTER IMPLANTATION IN HUMANS
Nelson, C. L., Hickmon, S. G., & HARRISON, B. H. (1994) · Orthopedics · doi:10.3928/0147-7447-19940501-06 · Cited by 77 · cited 1×
“Gentamicin-loaded PMMA beads implanted for treatment of orthopedic infections in patients for 3–36 weeks have been demonstrated to release high levels of antibiotic after retrieval [6].”
van de Belt, H., Neut, D., van Horn, J. R., van der Mei, H. C., Schenk, W., & Busscher, H. J. (1999) · Nature Medicine · doi:10.1038/7330 · Cited by 55
Self-citationHow I do it: Chronic osteomyelitis
Walenkamp, G. H. I. M. (1997) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679708996270 · Cited by 53
von Eiff, C., Lindner, N. J., Proctor, R. A., Winkelmann, W., & Peters, G. M. (1998) · PubMed · Cited by 35
In Vitro Elution of Tobramycin From Bioabsorbable Polycaprolactone Beads
Burd, T. A., Anglen, J. O., Lowry, K. J., Hendricks, K. J., & Day, D. E. (2001) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200108000-00007 · Cited by 26 · cited 1×
“In vitro results have already shown that polycaprolactone beads, made of a bioresorbable polymer, has superior antibiotic elution characteristics compared with PMMA beads [ 10 ].”
Cited by
The Chemistry and Applications of Antimicrobial Polymers: A State-of-the-Art Review
Kenawy, E.-R., Worley, S. D., & Broughton, R. (2007) · Biomacromolecules · doi:10.1021/bm061150q · Cited by 1,558
Biofilm Formation on Dental Restorative and Implant Materials
Busscher, H. J., Rinastiti, M., Siswomihardjo, W., & van der Mei, H. C. (2010) · Journal of Dental Research · doi:10.1177/0022034510368644 · Cited by 472
Self-citationCampoccia, D., Montanaro, L., Speziale, P., & Arciola, C. R. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.005 · Cited by 392
“In this regard it has to be mentioned that gentamicin-release tests revealed residual antibiotic release from the surface of cement beads after being 5 years in situ and extensive microbiological sampling of the same beads resulted in recovery of a gentamicin-resistant staphylococcal strain [112].”
McNally, M. A., Ferguson, J. Y., Lau, A. C. K., Diefenbeck, M., Scarborough, M., Ramsden, A. J., & Atkins, B. L. (2016) · The Bone & Joint Journal · doi:10.1302/0301-620x.98b9.38057 · Cited by 249
Howlin, R. P., Brayford, M. J., Webb, J. S., Cooper, J. J., Aiken, S. S., & Stoodley, P. (2015) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.03676-14 · Cited by 245
“Additionally, once the antibiotics have eluted from a nonabsorbable cement, the surface becomes a foreign body that is subject to bacterial colonization and biofilm formation (20, 21).”
BackgroundA novel cationic-peptide coating for the prevention of microbial colonization on contact lenses
Willcox, M. D. P., Hume, E. B. H., Aliwarga, Y., Kumar, N., & Cole, N. (2008) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2008.03942.x · Cited by 223
“Recently, gentamicin-resistant staphylococci were recovered from gentamicin-loaded PMMA beads implanted in a patient after arthroplasty (Neut et al. 2003), highlighting the dangers of the development of resistance from exposure to biomaterial-associated antimicrobials.”
BackgroundProphylaxis and treatment of implant-related infections by local application of antibiotics
Diefenbeck, M., Mückley, T., & Hofmann, G. O. (2006) · Injury · doi:10.1016/j.injury.2006.04.015 · Cited by 212
Local Antibiotic Therapy in Osteomyelitis
Gogia, J., Meehan, J., Di Cesare, P., & Jamali, A. (2009) · Seminars in Plastic Surgery · doi:10.1055/s-0029-1214162 · Cited by 207
Biodegradable vs non-biodegradable antibiotic delivery devices in the treatment of osteomyelitis
Kluin, O. S., van der Mei, H. C., Busscher, H. J., & Neut, D. (2013) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2013.751371 · Cited by 171
“Use of commercial, low-dose antibiotic bone cement for handmade spacers or beads is unwise as it results in a sub-therapeutic release [53,60] and bacteria growing near sub-therapeutic antibiotic concentrations theoretically pose a risk of developing antibiotic resistance [18,55].”
BackgroundMethodSelf-citationMcLaren, A. C. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000143554.56897.26 · Cited by 171
“This concern has not been realized in clinical practice,(9,17) although bacteria may be present without overt clinical manifestation.(35) As with all delivery vehicle materials, the antibiotic levels in the wound decrease over time.”
BackgroundSchnieders, J., Gbureck, U., Thull, R., & Kissel, T. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.032 · Cited by 169
Ceramic Biocomposites as Biodegradable Antibiotic Carriers in the Treatment of Bone Infections
Ferguson, J., Diefenbeck, M., & McNally, M. (2017) · Journal of Bone and Joint Infection · doi:10.7150/jbji.17234 · Cited by 161
“2014 (22) Calcium deficient hydroxyapatite (Bovine collagen Teicoplanin) 22 45 (23-77) 14/8 1.”
BackgroundInfluential
Metadata
- Authors
- Neut, D., van de Belt, H., van Horn, J. R., van der Mei, H. C., & Busscher, H. J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2003-05
- Volume
- 24
- Issue
- 10
- Pages
- 1829-1831
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1998484607
- Cited by
- 196
- References
- 9
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.