CoChat

Alternative Materials to Acrylic Bone Cement for Delivery of Depot Antibiotics in Orthopaedic Infections

McLaren, Alex C · 2004 · Clinical Orthopaedics and Related Research
Cited by 171

The DOI matches its Crossref record.

Abstract

Acrylic bone cement has considerable laboratory and clinical data validating it as a delivery material for depot administration of antibiotics. However, an alternate material that does not require a secondary procedure for removal is desired. Many biodegradable materials have been evaluated as alternatives including protein-based materials (collagen, fibrin, thrombin, clotted blood), bone-graft, bone-graft substitutes and extenders (hydroxyapatite, beta-tricalcium phosphate, calcium sulfate, bioglass), and synthetic polymers (polyhanhydride, polylactide, polyglycolide, polyhydroxybutyrate-co-hydroxyvalerate, polyhydroxyalkanoate). Various forms and combinations of these materials have been investigated worldwide, characterizing their elution properties and performance in treating osteomyelitis in animal models. Many of these have had limited clinical evaluation. Outside the United States, some of these materials are used clinically. In the United States, none have been approved. None are commercially available for clinical use. Morselized cancellous bone and calcium sulfate are the two materials that have been used clinically in the United States on a physician-prescribed, hand-mixed, basis. Considering the limited clinical data that currently are available, the use of these materials still is experimental. Clinical application should be cautious, limiting the total antibiotic load. Until definitive data are available, a prudent dose would be no higher than one that would have acceptable toxicity risk if administered intravenously over 24 hours.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.blo.0000143554.56897.26

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
McLaren, A. C.
Venue
Clinical Orthopaedics and Related Research
Published
2004-10
Volume
427
Issue
427
Pages
101-106
ISSN
0009-921X (ISSN-L)
OpenAlex
W1973175988
Cited by
171
References
0
FWCI
5.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Alternative Materials to Acrylic Bone Cement for Delivery of Depot Antibiotics in Orthopaedic Infections. https://app.cochat.ai/papers/10.1097/01.blo.0000143554.56897.26
The paper
McLaren, A. C. (2004). Alternative Materials to Acrylic Bone Cement for Delivery of Depot Antibiotics in Orthopaedic Infections. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/01.blo.0000143554.56897.26

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.