Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Abstract
A glucose-permeable hydrogel (97% water by mass) was formed by cross-linking an 8-armed, amine-terminated poly(ethylene glycol) (PEG) derivative with a di-succinimidyl ester of an alpha,omega-dipropionic acid derivative of PEG in aqueous solution at room temperature. The gel was evaluated as a biocompatible interface between an amperometric glucose electrode and the subcutaneous tissue of a rat. Over a glucose concentration range of 0-30 mM, the loss in sensitivity to glucose caused by the application of the hydrogel was 34% and the reduction in limiting current at high glucose concentration (30 mM) was 35% at 37 degrees C for films that were approximately 0.06 mm thick, an acceptable loss. Hydrogel and Pellethane samples were subcutaneously implanted in male Sprague-Dawley rats for 7 days. The explanted samples were thin-sectioned, stained and examined under a light microscope. While the Pellethane samples were encapsulated with tissue consisting of macrophages, neutrophils, foreign body giant cells, fibroblasts and collagen, the PEG samples had very few adherent cells. The results show this system to be a good candidate for providing biocompatible interfaces for sensors, especially oxidoreductase-based sensors.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pellethane control substrates showed significant inflammatory cell adherence and collagen encapsulation, whereas PEG-modified hydrogels had fewer cells, indicating improved biocompatibility.
“While Pellethane (i.e., polyurethane) control substrates exhibited significant inflammatory cell adherence and collagen encapsulation, PEG-modified hydrogels were characterized by less cells indicating improved biocompatibility.144”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [144]
The citation lists haven’t been fetched yet
References 33 · Cited by 126
- Authors
- Quinn, C. A. P., Connor, R. E., & Heller, A.
- Affiliations
- The University of Texas at Austin (US)
- Corresponding author
- Heller, Adam
- ORCID
- Heller, Adam
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1997-12
- Volume
- 18
- Issue
- 24
- Pages
- 1665-1670
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1998734017
- Cited by
- 126
- References
- 33
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 1 · 2022: 6 · 2021: 4 · 2020: 6 · 2019: 6 · 2018: 7 · 2017: 2 · 2016: 8 · 2015: 7 · 2014: 4 · 2013: 4 · 2012: 9
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk042015-07)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK42015)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- implantable biosensors, biocompatibility, subcutaneous implantation, foreign body reaction, glucose sensitivity
- MeSH terms
- Animals, Biocompatible Materials, Cell Adhesion, Cross-Linking Reagents, Coloring Agents, Electrodes, Implanted, Gels, Glucose, Male, Polyethylene Glycols, Polyurethanes, Succinimides, Biosensing Techniques, Rats, Sprague-Dawley, Hydrogel, Polyethylene Glycol Dimethacrylate, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.