Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

In vitro degradation of a novel poly(lactide-co-glycolide) 75/25 foam

Abstract

Macroporous poly(lactide-co-glycolide) PLGA 75/25 foams were prepared for application in bone tissue engineering. Their in vitro degradation behaviour was followed over a 30 week period at 37 degrees C and at one of three pHs: (1) pH 5.0, which mimics the acidic environment produced by activated macrophages, (2) pH 7.4, which reproduces normal physiological conditions and (3) an intermediate pH 6.4. The degradation of the PLGA 75/25 foams was studied by measuring changes in mass, molecular weight and morphology. The degradation profile of foams maintained at pH 5.0, 6.4 and 7.4 was similar until week 16, after which foams maintained at pH 6.4 and 7.4 had comparable degradation patterns whereas foams maintained at pH 5.0 degraded faster. For example, mass loss was less than 3% for foams maintained at all three pHs until week 16; however, by week 30, foams maintained at pH 6.4 and 7.4 had lost 30% of their mass whereas foams maintained at pH 5.0 had lost 90% of their mass. Foams maintained at pH 6.4 and 7.4 showed a similar constant decrease in molecular weight over the entire degradation study. Foams maintained at pH 5.0 had a similar rate of molecular weight loss as those maintained at pH 6.4 and 7.4 until week 16, after which the rate of molecular weight loss of foams maintained at pH 5.0 was accelerated. The morphology of the foams maintained at pH 6.4 and 7.4 was unchanged for 25 weeks. Foams maintained at pH 5.0 collapsed after week 18. Thus the PLGA 75/25 foams, describe…

Overview

Integrity signals

Registry

Crossref · 10.1016/s0142-9612(98)00256-7

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Cited by

See all 270

Metadata

Authors
Holy, C. E., Dang, S. M., Davies, J. E., & Shoichet, M. S.
Affiliations
University of Toronto (CA)
Corresponding author
Shoichet, Molly S.
Venue
Biomaterials
Publisher
Elsevier BV
Published
1999-07
Volume
20
Issue
13
Pages
1177-1185
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2157684229
Cited by
241
References
15
Citations by year
2026: 2 · 2025: 5 · 2024: 8 · 2023: 8 · 2022: 4 · 2021: 10 · 2020: 10 · 2019: 15 · 2018: 7 · 2017: 8 · 2016: 12 · 2015: 9 · 2014: 11 · 2013: 10 · 2012: 14
FWCI
5.00
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health
  • Medical Research Council
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Materials Science › Biomaterials › Magnesium Alloys: Properties and Applications
Keywords
poly(lactic-co-glycolic acid), macroporous scaffolds, in vitro degradation, pH-dependent degradation, bone tissue engineering, molecular weight reduction, foam structure, biodegradable polymers
MeSH terms
Polylactic Acid-Polyglycolic Acid Copolymer, Buffers, Drug Stability, Hydrogen-Ion Concentration, Microscopy, Electron, Scanning, Molecular Weight, Polyglycolic Acid, Polymers, Time Factors, Bone Substitutes, Lactic Acid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vitro degradation of a novel poly(lactide-co-glycolide) 75/25 foam. https://app.cochat.ai/papers/10.1016/s0142-9612(98)00256-7
The paper
Holy, C. E., Dang, S. M., Davies, J. E., & Shoichet, M. S. (1999). In vitro degradation of a novel poly(lactide-co-glycolide) 75/25 foam. Biomaterials. https://doi.org/10.1016/s0142-9612(98)00256-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.