PEG-variant biomaterials as selectively adhesive protein templates: model surfaces for controlled cell adhesion and migration
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein—surface interactions in the presence of polyethylene oxide
Jeon, S. I., Lee, J. H., Andrade, J. D., & De Gennes, P. G. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90043-8 · Cited by 1,523
Integrin-ligand binding properties govern cell migration speed through cell-substratum adhesiveness
Palecek, S. P., Loftus, J. C., Ginsberg, M. H., Lauffenburger, D. A., & Horwitz, A. F. (1997) · Nature · doi:10.1038/385537a0 · Cited by 1,427 · cited 1×
“7) may be the result of PEG levels a!ecting di!erentially (a) ligand conformation, and hence the binding a$nity between the adsorbed ligand and its receptor, e!ectively altering the strength of the adhesive bond [40], or (b) the strength by which the 518 E.”
BackgroundPale-Grosdemange, C., Simon, E. S., Prime, K. L., & Whitesides, G. M. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00001a002 · Cited by 673 · cited 1×
“When PEG concentration was increased to 10 mol%, the receding contact angle decreased to values similar to those reported for self-assembled monolayers of PEG [32].”
ResultGarcı́a, A. J., Vega, M. D., & Boettiger, D. (1999) · Molecular Biology of the Cell · doi:10.1091/mbc.10.3.785 · Cited by 659 · cited 1×
“Furthermore, since the conformation of adsorbed cell adhesion proteins can play a crucial role in determining whether cells proliferate or di!erentiate [46], the presence of small amounts of PEG on biomaterial surfaces may also prove useful to switch the balance between cell growth and di!erentiation.”
BackgroundDiMilla, P., Stone, J., Quinn, J., Albelda, S., & Lauffenburger, D. (1993) · The Journal of cell biology · doi:10.1083/jcb.122.3.729 · Cited by 600
Mechanism of polyethylene glycol interaction with proteins
Arakawa, T., & Timasheff, S. N. (1985) · Biochemistry · doi:10.1021/bi00345a005 · Cited by 467 · cited 1×
“In addition, since PEG acts as a stabilizer of the globular form of proteins [47], at higher PEG concentration, adsorbed FN may be present in the form of more compact, globular conformations with a large degree of RGD encryption, which may explain the lower speci"c protein bioactivity (Fig.”
BackgroundProtein‐resistant surfaces prepared by PEO‐containing block copolymer surfactants
Lee, J. H., Kopecek, J., & Andrade, J. D. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230306 · Cited by 436 · cited 1×
“Typically, PEG has been incorporated onto biomaterial surfaces through grafting [4}6], via simple surface treatments based on primary adsorption [7}9]; or secondary adsorption [10]; and through bulk incorporation via crosslinking [11] or block copolymerization [12,13].”
MethodLotz, M. M., Burdsal, C. A., Erickson, H. P., & McClay, D. R. (1989) · The Journal of cell biology · doi:10.1083/jcb.109.4.1795 · Cited by 412 · cited 1×
“A likely explanation for these trends is that after cells attach to adsorbed surface ligands, they may be able to rearrange both membrane receptors and surface ligands and in the process facilitate further binding [38].”
BackgroundBhat, R., & Timasheff, S. N. (1992) · Protein Science · doi:10.1002/pro.5560010907 · Cited by 374
Amiji, M., & Park, K. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90128-b · Cited by 359 · cited 1×
“Ever since the recognition of the antithrombogenic action of PEG [14], the design of most PEG-derivatized surfaces has sought to eliminate cell and protein adhesion using high PEG surface concentration [5,7,12].”
Background
Cited by
Herzberger, J., Niederer, K., Pohlit, H., Seiwert, J., Worm, M., Wurm, F. R., & Frey, H. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00441 · Cited by 865
Biocompatible polymer materials: Role of protein–surface interactions
Chen, H., Yuan, L., Song, W., Wu, Z., & Li, D. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.006 · Cited by 706
Circular Dichroism Techniques: Biomolecular and Nanostructural Analyses‐ A Review
Ranjbar, B., & Gill, P. (2009) · Chemical Biology & Drug Design · doi:10.1111/j.1747-0285.2009.00847.x · Cited by 682
Keselowsky, B. G., Collard, D. M., & Garcı́a, A. J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.062 · Cited by 627
Design, fabrication and characterization of PCL electrospun scaffolds—a review
Cipitria, A., Skelton, A., Dargaville, T. R., Dalton, P. D., & Hutmacher, D. W. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm04502k · Cited by 627
Surface modification and property analysis of biomedical polymers used for tissue engineering
Ma, Z., Mao, Z., & Gao, C. (2007) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2007.06.019 · Cited by 590
Nanomedicine for implants: A review of studies and necessary experimental tools
Liu, H., & Webster, T. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.049 · Cited by 579
Rational Design of Cytophilic and Cytophobic Polyelectrolyte Multilayer Thin Films
Mendelsohn, J. D., Yang, S. Y., Hiller, J., Hochbaum, A. I., & Rubner, M. F. (2003) · Biomacromolecules · doi:10.1021/bm0256101 · Cited by 461
Biocompatibility Testing of Branched and Linear Polyglycidol
Kainthan, R. K., Janzen, J., Levin, E., Devine, D. V., & Brooks, D. E. (2006) · Biomacromolecules · doi:10.1021/bm0504882 · Cited by 393
The effect of hydrogel charge density on cell attachment
Schneider, G. B., English, A., Abraham, M., Zaharias, R., Stanford, C., & Keller, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.084 · Cited by 314
C−H Functionalization of Commodity Polymers
Williamson, J. B., Lewis, S. E., Johnson, R. R., Manning, I. M., & Leibfarth, F. A. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201810970 · Cited by 313
Advanced biomaterials for skeletal tissue regeneration: Instructive and smart functions
Barrère, F., Mahmood, T. A., de Groot, K., & van Blitterswijk, C. A. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.12.001 · Cited by 303
Cytoskeleton-based forecasting of stem cell lineage fates
Treiser, M. D., Yang, E. H., Gordonov, S., Cohen, D. M., Androulakis, I. P., Kohn, J., Chen, C. S., & Moghe, P. V. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909597107 · Cited by 295
Self-citationBoulmedais, F., Frisch, B., Etienne, O., Lavalle, P., Picart, C., Ogier, J., Voegel, J.-C., Schaaf, P., & Egles, C. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.039 · Cited by 259
Allen, L. T., Tosetto, M., Miller, I. S., O’Connor, D. P., Penney, S. C., Lynch, I., Keenan, A. K., Pennington, S. R., Dawson, K. A., & Gallagher, W. M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.019 · Cited by 245
Ryan, P. L., Foty, R. A., Kohn, J., & Steinberg, M. S. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.071615398 · Cited by 245
Self-citationBourke, S. L., & Kohn, J. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(03)00038-3 · Cited by 238
Self-citationSurface engineering strategies for control of protein and cell interactions
Nath, N., Hyun, J., Ma, H., & Chilkoti, A. (2004) · Surface Science · doi:10.1016/j.susc.2004.06.182 · Cited by 232
Biodegradable PEG-Based Amphiphilic Block Copolymers for Tissue Engineering Applications
Kutikov, A. B., & Song, J. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00122 · Cited by 205
Biomimetic hydrogels designed for cartilage tissue engineering
Ngadimin, K. D., Stokes, A., Gentile, P., & Ferreira, A. M. (2021) · Biomaterials Science · doi:10.1039/d0bm01852j · Cited by 202
Injectable hydrogels based on poly(ethylene glycol) and derivatives as functional biomaterials
Bakaic, E., Smeets, N. M. B., & Hoare, T. (2015) · RSC Advances · doi:10.1039/c4ra13581d · Cited by 184
Short-Term and Long-Term Effects of Orthopedic Biodegradable Implants
Amini, A. R., Wallace, J. S., & Nukavarapu, S. P. (2011) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v21.i2.10 · Cited by 181
Molecularly engineered p(HEMA)-based hydrogels for implant biochip biocompatibility
Abraham, S., Brahim, S., Ishihara, K., & Guiseppi-Elie, A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.01.031 · Cited by 180
“Similarly, synthetic PEG or its high molecular weight equivalent, poly(ethylene oxide), has been widely studied and is commonly used to confer protein-resistant characteristics to surfaces [24–29], as well as to provide a matrix for protein/ biomolecule stabilization and hence promote long-term bioactivity [30] of imm…”
Nolan, C. M., Reyes, C. D., Debord, J. D., García, A. J., & Lyon, L. A. (2005) · Biomacromolecules · doi:10.1021/bm0500087 · Cited by 175
Tamesue, S., Ohtani, M., Yamada, K., Ishida, Y., Spruell, J. M., Lynd, N. A., Hawker, C. J., & Aida, T. (2013) · Journal of the American Chemical Society · doi:10.1021/ja408547g · Cited by 161
Metadata
- Authors
- Tziampazis, E., Kohn, J., & Moghe, P. V.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2000-03
- Volume
- 21
- Issue
- 5
- Pages
- 511-520
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2123697633
- Cited by
- 220
- References
- 40
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.