Scanning Slit Confocal Microscopic Observation of Cell Morphology and Movement within the Normal Human Anterior Cornea
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
PURPOSE: Noninvasive in vivo observations of the anterior human cornea were performed to study cell structure and dynamics. Cellular elements were identified by their location, morphology, and pattern of movement. The hypothesis that cells in the epithelial layer of the normal cornea migrate centripetally was tested. METHODS: Using a scanning slit confocal microscope with a new 0.75-numeric aperture contact objective, individual cells of normal human corneas were observed over time, quantifying the velocity and direction of cellular movement within the basal epithelial layer. RESULTS: Basal epithelial cells, wing cells, the basal epithelial nerve plexus, and the subepithelial nerve plexus were identified readily. Centripetal motion was observed for three corneal cell types: basal epithelial cells, basal epithelial nerves, and unidentified cellular elements (possibly Langerhans cells). The unidentified cellular elements moved along the length of the basal epithelial nerves. The basal epithelial nerve plexus maintained a roughly stable topology as it slid centripetally. New nerve material appeared at the site of entry of the nerve into the epithelium. No growth cones were present at the distal termini of the growing epithelial nerves. CONCLUSION: In the midperiphery of the normal human cornea, basal epithelial cells and nerves slide centripetally, probably in concert. Unidentified cellular elements used the basal epithelial nerve plexus as a pathway for intraepithelial movement. Observations in this study suggest that neurite growth occurred by the addition of new membrane material along the length of the axon rather than at a distal growth cone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CANNON, B., & by Stewart Duke-Elder, E. (1973) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-197311000-00020 · Cited by 1,982
The X, Y, Z hypothesis of corneal epithelial maintenance.
Thoft, R. A., & Friend, J. (1983) · PubMed · Cited by 656
The anatomy of the visual system
Duke-Elder, S., & Wybar, K. C. (1961) · Henry Kimpton eBooks · Cited by 339
Clinical and Diagnostic Use of In Vivo Confocal Microscopy in Patients with Corneal Disease
Cavanagh, H. D., Petroll, W. M., Alizadeh, H., He, Y.-G., McCulley, J. P., & Jester, J. V. (1993) · Ophthalmology · doi:10.1016/s0161-6420(93)31457-0 · Cited by 266
Measurement of centripetal migration of normal corneal epithelial cells in the mouse.
Buck, R. C. (1985) · PubMed · Cited by 205
Nerve structures in human central corneal epithelium
Schimmelpfennig, B. (1982) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf02134093 · Cited by 156
Stafstrom, C. E. (1990) · Journal of Epilepsy · doi:10.1016/0896-6974(90)90164-t · Cited by 146
The Cornea. Transactions of the World Congress on the Cornea, III.
Sugar, A. (1988) · American Journal of Ophthalmology · doi:10.1016/0002-9394(88)90616-2 · Cited by 138
Real-time scanning slit confocal microscopy of the in vivohuman cornea
Masters, B. R., & Thaer, A. (1994) · Applied Optics · doi:10.1364/ao.33.000695 · Cited by 121
Forward Plasma Membrane Flow in Growing Nerve Processes
Popov, S., Brown, A., & Poo, M.-M. (1993) · Science · doi:10.1126/science.7678471 · Cited by 78
Cited by
Corneal nerves: structure, contents and function
Müller, L. J., Marfurt, C. F., Kruse, F., & Tervo, T. M. T. (2003) · Experimental Eye Research · doi:10.1016/s0014-4835(03)00050-2 · Cited by 1,220
Involvement of Follicular Stem Cells in Forming Not Only the Follicle but Also the Epidermis
Taylor, G., Lehrer, M. S., Jensen, P. J., Sun, T.-T., & Lavker, R. M. (2000) · Cell · doi:10.1016/s0092-8674(00)00050-7 · Cited by 1,070
Morphology of Corneal Nerves Using Confocal Microscopy
Oliveira-Soto, L., & Efron, N. (2001) · Cornea · doi:10.1097/00003226-200105000-00008 · Cited by 501
Anatomy of the human corneal innervation
Marfurt, C. F., Cox, J., Deek, S., & Dvorscak, L. (2010) · Experimental Eye Research · doi:10.1016/j.exer.2009.12.010 · Cited by 498
Corneal nerves in health and disease
Shaheen, B. S., Bakir, M., & Jain, S. (2014) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2013.09.002 · Cited by 474
Strategies of epithelial repair: Modulation of stem cell and transit amplifying cell proliferation
Lehrer, M. S., Sun, T.-T., & Lavker, R. M. (1998) · Journal of Cell Science · doi:10.1242/jcs.111.19.2867 · Cited by 416
In vivo confocal microscopy of the human cornea
Jalbert, I. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.2.225 · Cited by 371
In Vivo Confocal Microscopy of Corneal Nerves in Health and Disease
Cruzat, A., Qazi, Y., & Hamrah, P. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2016.09.004 · Cited by 364
Patel, D. V., & McGhee, C. N. J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0794 · Cited by 284
Patel, D. V., & McGhee, C. N. J. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.150615 · Cited by 247
Silicone Hydrogel Contact Lenses and the Ocular Surface
Stapleton, F., Stretton, S., Papas, E., Skotnitsky, C., & Sweeney, D. F. (2006) · The Ocular Surface · doi:10.1016/s1542-0124(12)70262-8 · Cited by 236
Clinical in vivo confocal microscopy of the human cornea in health and disease
Niederer, R. L., & McGhee, C. N. J. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2009.11.001 · Cited by 215
“Interestingly, a subsequent study has observed that whilst stromal nerves and their perforation points through Bowman's layer remain constant, the basal epithelial cells and subbasal nerve plexus slides centripetally at a variable rate of 1.7e32 mm per day (Auran et al., 1995).”
Patel, D. V., & McGhee, C. N. (2007) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2007.01423.x · Cited by 193
“When imaged by in vivo confocal microscopy, they appear as thick, reflective linear structures of various orientations, which branch in a dichotomous pattern;(26) however, no internal detail of stromal nerves is visible.(52)”
BackgroundInfluentialThe effect of hinge position on corneal sensation and dry eye after LASIK
Donnenfeld, E. D., Solomon, K., Perry, H. D., Doshi, S. J., Ehrenhaus, M., Solomon, R., & Biser, S. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00100-3 · Cited by 189
Mapping the entire human corneal nerve architecture
He, J., Bazan, N. G., & Bazan, H. E. P. (2010) · Experimental Eye Research · doi:10.1016/j.exer.2010.07.007 · Cited by 181
“Since then, different staining and fixation techniques and a variety of analytic methods have increased information on the morphology, ultrastructural organization, density, and postmortem changes of corneal nerves (Auran et al., 1995; Müller et al., 1996; Müller et al., 1997; Ueda et al., 1989).”
Background
Metadata
- Authors
- Auran, J. D., Koester, C. J., Kleiman, N. J., Rapaport, R., Bomann, J. S., Wirotsko, B. M., Florakis, G. J., & Koniarek, J. P.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 1995-01
- Volume
- 102
- Issue
- 1
- Pages
- 33-41
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2026767326
- Cited by
- 163
- References
- 12
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.