Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record.

Correlation of tear fluorescein clearance and schirmer test scores with ocular irritation symptoms

Open access
Afonso, Adolfo A, Monroy, Dagoberto, Stern, Michael E, Feuer, William J, Tseng, Scheffer C.G, Pflugfelder, Stephen C·1999·Ophthalmology

Abstract

OBJECTIVE: To correlate and compare the Schirmer 1 test and a new method of measuring tear fluorescein clearance with the CytoFluor II fluorometer with the severity of ocular irritation symptoms, clinical signs of meibomian gland disease, corneal fluorescein staining scores, and corneal and conjunctival sensitivity. DESIGN: Case-control study. PARTICIPANTS: Forty patients presenting with a chief complaint of ocular irritation, and 40 asymptomatic control subjects of similar age distribution. INTERVENTION: All subjects completed a symptom questionnaire, a baseline ocular examination, fluorescein clearance test (FCT), and Schirmer 1 test. MAIN OUTCOME MEASURES: The FCT was performed with a CytoFluor II fluorophotometer by measuring the fluorescein concentration in minimally stimulated tear samples collected from the inferior tear meniscus 15 minutes after instillation of 5 microl of 2% sodium fluorescein. Severity of ocular irritation was assessed with a symptom questionnaire. Schirmer 1 test, biomicroscopic meibomian gland evaluation, corneal fluorescein staining score, and corneal and conjunctival sensation scores were assessed with the Cachet-Bonnet anesthesiometer in all subjects. RESULTS: Irritation symptoms correlated with higher log tear fluorescein concentration (symptomatic 3.08 +/- 0.62 units/,microl, normal control 1.89 +/- 0.7 units/microl, P < 0.005) and lower Schirmer 1 test scores (symptomatic 12.6 mm, normal control 22.3 mm, P < 0.005). The FCT showed greater predictive value for identifying ocular irritation than the Schirmer 1 test. A fluorescein concentration of 274 units//microl eliminated 80% of the normal subjects (specificity) and identified 85% of the abnormal subjects (sensitivity). Log of tear fluorescein concentration and the Schirmer 1 test correlated with meibomian gland orifice metaplasia (2.81 +/- 0.78 units/microl and 14.47 +/- 9.53 mm in those with metaplasia vs. 1.83 +/- 0.71 units/microl and 23.14 +/- 7.67 mm in those without metaplasia, P < 0.001) and with the percentage of acinar dropout. Both log of tear fluorescein concentration and the Schirmer 1 test correlated with corneal fluorescein staining (Pearson correlation of 0.394 P < 0.0001 for Schirmer 1 test and 0.312 P < 0.005 for log of tear fluorescein). In addition, log of tear fluorescein and Schirmer 1 test scores correlated with corneal and conjunctival sensation scores (Spearman's rho for corneal sensation: log of tear fluorescein -0.38, P < 0.003, Schirmer 1 test -0.39, P < 0.002, and for conjunctival sensation: log of tear fluorescein -0.391, P < 0.001, Schirmer 1 test -0.23, P < 0.061). CONCLUSIONS: The FCT shows a greater predictive value for ocular irritation than the Schirmer 1 test. It correlates better with age, meibomian gland dysfunction, and decreased corneal and conjunctival sensation. Decreased tear clearance was identified as a risk factor for ocular irritation, even in subjects with normal Schirmer scores. This simple technique may provide new clues into the mechanism and therapy of ocular irritation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0161-6420(99)90170-7

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Afonso, A. A., Monroy, D., Stern, M. E., Feuer, W. J., Tseng, S. C. G., & Pflugfelder, S. C.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
1999-04
Volume
106
Issue
4
Pages
803-810
ISSN
0161-6420 (ISSN-L)
OpenAlex
W2147254926
Cited by
196
References
0
FWCI
7.10
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlation of tear fluorescein clearance and schirmer test scores with ocular irritation symptoms. https://app.cochat.ai/papers/10.1016/s0161-6420(99)90170-7
The paper
Afonso, A. A., Monroy, D., Stern, M. E., Feuer, W. J., Tseng, S. C. G., & Pflugfelder, S. C. (1999). Correlation of tear fluorescein clearance and schirmer test scores with ocular irritation symptoms. Ophthalmology. https://doi.org/10.1016/s0161-6420(99)90170-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.