Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,446

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Grading Of Corneal and Conjunctival Staining in the Context of Other Dry Eye Tests

Bron, Anthony J., Evans, Victoria E., Smith, Janine A.·2003·Cornea

Abstract

PURPOSE: To describe the Oxford Scheme for grading ocular surface staining in dry eye and to discuss optimization of stain detection using various dyes and filters. Also, to propose a sequence of testing for dry eye diagnosis. METHODS: The grading of corneal and conjunctival staining is described, using the Oxford Scheme, including biomicroscopy, optical filters, illumination conditions, and the characteristics of and instillation techniques used for, selected clinical dyes. RESULTS: A series of panels, labeled A-E, in order of increasing severity, reproducing the staining patterns encountered in dry eye, are used as a guide to grade the degree of staining seen in the patient. The amount of staining seen in each panel, represented by punctate dots, increases by 0.5 of the log of the number of dots between panels B to E. The use of the vital dyes fluorescein, lissamine green, and rose Bengal is described; fluorescein and lissamine green, used in conjunction with appropriate absorption filters, are recommended for use in clinical trials. The placement of staining in relation to the sequence of other diagnostic tests is discussed. CONCLUSIONS: The monitoring and assessment of corneal and conjunctival staining can be greatly enhanced by the use of a grading scale, controlled instillation of dyes, and standard evaluation techniques. This is of particular benefit in clinical trials, where ocular surface staining is commonly employed as an outcome measure

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003226-200310000-00008

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 1,446

Metadata

Authors
Bron, A. J., Evans, V. E., & Smith, J. A.
Venue
Cornea
Published
2003-10
Volume
22
Issue
7
Pages
640-650
ISSN
0277-3740 (ISSN-L)
OpenAlex
W2055370551
Cited by
1,446
References
25
FWCI
6.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Grading Of Corneal and Conjunctival Staining in the Context of Other Dry Eye Tests. https://app.cochat.ai/papers/10.1097/00003226-200310000-00008
The paper
Bron, A. J., Evans, V. E., & Smith, J. A. (2003). Grading Of Corneal and Conjunctival Staining in the Context of Other Dry Eye Tests. Cornea. https://doi.org/10.1097/00003226-200310000-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.