Microelectrode arrays for stimulation of neural slice preparations
Open accessThe DOI matches its Crossref record.
Abstract
A planar 6 x 6 array of iridium electrodes with four reference electrodes has been developed for use with neural tissue preparations. Precise knowledge of the relative locations of the array elements allows for spatial neurophysiological analyses. The 10 microns diameter platinized iridium electrodes on a 100 microns pitch have been used to stimulate acutely prepared slices of spinal cord from free-ranging rodents. An intracellular recording from a single neuron in the substantia gelatinosa (SG) using the whole-cell, tight-seal technique allowed low noise, high resolution studies of excitatory or inhibitory electrical responses of a given neuron to inputs from the primary afferent fibers or from stimulation by individual electrodes of the array. The resulting maps of responses provide an indication of the interconnectivity of neural processes. The pattern emerging is that of limited interconnectivity in the SG from areas surrounding a recorded neuron but with strong excitatory or inhibitory effects from those oriented in a longitudinal (rostral-caudal) direction relative to the neuron. The observations to date suggest the neurons of the SG are arranged in sets of independent networks, possibly related to sensory modality and input from particular body regions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Patterning proteins and cells using soft lithography
Kane, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,490
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
A surface chemistry approach to studying cell adhesion
Mrksich, M. (2000) · Chemical Society Reviews · doi:10.1039/a705397e · Cited by 461
Ostuni, E., Yan, L., & Whitesides, G. M. (1999) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00004-1 · Cited by 453
Retinal Ganglion Cells Do Not Extend Axons by Default
Goldberg, J. L., Espinosa, J. S., Xu, Y., Davidson, N., Kovacs, G. T. A., & Barres, B. A. (2002) · Neuron · doi:10.1016/s0896-6273(02)00602-5 · Cited by 451
Self-citation
Metadata
- Authors
- Borkholder, D. A., Bao, J., Maluf, N. I., Perl, E. R., & Kovacs, G. T. A.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1997-11
- Volume
- 77
- Issue
- 1
- Pages
- 61-66
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2021196089
- Cited by
- 96
- References
- 0
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microelectrode arrays for stimulation of neural slice preparations. https://app.cochat.ai/papers/10.1016/s0165-0270(97)00112-x
- The paper
- Borkholder, D. A., Bao, J., Maluf, N. I., Perl, E. R., & Kovacs, G. T. A. (1997). Microelectrode arrays for stimulation of neural slice preparations. Journal of Neuroscience Methods. https://doi.org/10.1016/s0165-0270(97)00112-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.