Reduction of background autofluorescence in brain sections following immersion in sodium borohydride
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Autofluorescence of aldehyde-fixed neural tissue often obscures perikaria and fine processes labeled with fluorescent anterograde or retrograde tracers. In particular, this autofluorescence hinders the detectability of fine axonal projections labeled with the convenient anterograde tracer, tetramethylrhodamine dextranamine. Background fluorescence was notably reduced by immersion of free-floating brain tissue sections in a solution of sodium borohydride (NaBH4, 0.1%), a chemical which is known to neutralize Schiffs bases through reduction of amine-aldehyde compounds into non-fluorescent salts. The reversible and renewable immersion technique was most effective in paraformaldehyde-fixed tissue where the preservation quality was improved such that labeled axons remained detectable for more than 1 year after initial preparation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biotinylated dextran amine as an anterograde tracer for single- and double-labeling studies
Veenman, C. L., Reiner, A., & Honig, M. G. (1992) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(92)90089-v · Cited by 608
Kuypers, H. G. J. M., Bentivoglio, M., Catsman-Berrevoets, C. E., & Bharos, A. T. (1980) · Experimental Brain Research · doi:10.1007/bf00236147 · Cited by 406
Sawchenko, P. E., & Swanson, L. W. (1981) · Brain Research · doi:10.1016/0006-8993(81)90882-9 · Cited by 313
Retrograde anoxal transport of fluorescent substances in the rat's forebrain
Kuypers, H. G. J. M., Catsman-Berrevoets, C. E., & Padt, R. E. (1977) · Neuroscience Letters · doi:10.1016/0304-3940(77)90007-6 · Cited by 284
Schmued, L., Kyriakidis, K., & Heimer, L. (1990) · Brain Research · doi:10.1016/0006-8993(90)90258-d · Cited by 236
A Major Direct GABAergic Pathway from Zona Incerta to Neocortex
Lin, C.-S., Nicolelis, M. A. L., Schneider, J. S., & Chapin, J. K. (1990) · Science · doi:10.1126/science.2360049 · Cited by 169
Swanson, L. W., Sawchenko, P. E., & Cowan, W. M. (1980) · Brain Research · doi:10.1016/0006-8993(80)90446-1 · Cited by 165
Beisker, W., Dolbeare, F. A., & Gray, J. W. (1987) · Cytometry · doi:10.1002/cyto.990080218 · Cited by 139
Willingham, M. C. (1983) · Journal of Histochemistry & Cytochemistry · doi:10.1177/31.6.6404984 · Cited by 123
Fluorescent dextrans as sensitive anterograde neuroanatomical tracers: Applications and pitfalls
Nance, D. M., & Burns, J. (1990) · Brain Research Bulletin · doi:10.1016/0361-9230(90)90264-z · Cited by 113
The Use of axonal transport for studies of neuronal connectivity
Cowan, W. M., & Cuénod, M. (1975) · Elsevier eBooks · Cited by 106
Layer VII of rodent cerebral cortex
Reep, R. L., & Goodwin, G. S. (1988) · Neuroscience Letters · doi:10.1016/0304-3940(88)90779-3 · Cited by 55
Hirsch, M. D., & Helke, C. J. (1988) · Neuroscience · doi:10.1016/0306-4522(88)90264-3 · Cited by 43
Cited by
Richardson, D. S., & Lichtman, J. W. (2015) · Cell · doi:10.1016/j.cell.2015.06.067 · Cited by 1,095
“A number of techniques reduce autofluorescence somewhat, including: bleaching with high-intensity lighting (Duong and Han, 2013), sodium borohydride treatment to eliminate Schiffs bases (Clancy and Cauller, 1998), and spectral unmixing to remove broadband fluorescent signals (Zimmermann, 2005).”
Protein localization in electron micrographs using fluorescence nanoscopy
Watanabe, S., Punge, A., Hollopeter, G., Willig, K. I., Hobson, R. J., Davis, M. W., Hell, S. W., & Jorgensen, E. M. (2011) · Nature Methods · doi:10.1038/nmeth.1537 · Cited by 351
Multispectral imaging in biology and medicine: Slices of life
Levenson, R. M., & Mansfield, J. R. (2006) · Cytometry Part A · doi:10.1002/cyto.a.20319 · Cited by 288
Cremer, M., Küpper, K., Wagler, B., Wizelman, L., Hase, J. V., Weiland, Y., Kreja, L., Diebold, J., Speicher, M. R., & Cremer, T. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200304096 · Cited by 261
Kopek, B. G., Shtengel, G., Xu, C. S., Clayton, D. A., & Hess, H. F. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1121558109 · Cited by 238
“Glutaraldehyde at a 2% (wt/vol) concentration generates a prohibitive amount of autofluorescence; however, this was mitigated by a brief treatment with sodium borohydride (25) before fluorescence imaging.”
Background
Metadata
- Authors
- Clancy, B., & Cauller, L. J.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1998-09
- Volume
- 83
- Issue
- 2
- Pages
- 97-102
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W1964440939
- Cited by
- 193
- References
- 13
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.