The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Recent development and applications of optical and fiber-optic pH sensors
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Cited by 9,358
Clark, H. A., Hoyer, M., Philbert, M. A., & Kopelman, R. (1999) · Analytical Chemistry · doi:10.1021/ac990629o · Cited by 355
Clark, H. A., Kopelman, R., Tjalkens, R., & Philbert, M. A. (1999) · Analytical Chemistry · doi:10.1021/ac990630n · Cited by 321
Sol-gel glass as a matrix for chemical and biochemical sensing
Lin, J., & Brown, C. W. (1997) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(97)00021-6 · Cited by 276
Self-citationSubmicrometer Intracellular Chemical Optical Fiber Sensors
Tan, W., Shi, Z.-Y., Smith, S., Birnbaum, D., & Kopelman, R. (1992) · Science · doi:10.1126/science.1439785 · Cited by 271
Equilibrium studies on colorimetric plastic film sensors for carbon dioxide
Mills, A., Chang, Q., & McMurray, N. (1992) · Analytical Chemistry · doi:10.1021/ac00037a015 · Cited by 219
pH optical sensors based on sol–gels: Chemical doping versus covalent immobilization
Lobnik, A., Oehme, I., Murkovic, I., & Wolfbeis, O. S. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00708-3 · Cited by 218
Doped sol-gel glasses as chemical sensors
Zusman, R., Rottman, C., Ottolenghi, M., & Avnir, D. (1990) · Journal of Non-Crystalline Solids · doi:10.1016/0022-3093(90)90232-b · Cited by 213
Optical measurements of pH using fluorescence lifetimes and phase-modulation fluorometry
Szmacinski, H., & Lakowicz, J. R. (1993) · Analytical Chemistry · doi:10.1021/ac00061a007 · Cited by 168
Development of submicron chemical fiber optic sensors
Tan, W., Shi, Z. Y., & Kopelman, R. (1992) · Analytical Chemistry · doi:10.1021/ac00047a019 · Cited by 154
Cited by
Fiber Optic Sensors in Structural Health Monitoring
Lopez-Higuera, J. M., Rodriguez Cobo, L., Quintela Incera, A., & Cobo, A. (2011) · Journal of Lightwave Technology · doi:10.1109/jlt.2011.2106479 · Cited by 783
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Ghoneim, M. T., Nguyen, A., Dereje, N., Huang, J., Moore, G. C., Murzynowski, P. J., & Dagdeviren, C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00655 · Cited by 317
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
Moradi, V., Akbari, M., & Wild, P. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.07.031 · Cited by 42
Metadata
- Authors
- Lin, J.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2000-09
- Volume
- 19
- Issue
- 9
- Pages
- 541-552
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W1982694352
- Cited by
- 271
- References
- 26
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent development and applications of optical and fiber-optic pH sensors. https://app.cochat.ai/papers/10.1016/s0165-9936(00)00034-0
- The paper
- Lin, J. (2000). Recent development and applications of optical and fiber-optic pH sensors. TrAC Trends in Analytical Chemistry. https://doi.org/10.1016/s0165-9936(00)00034-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.