Overview of clinical experiences on carbon ion radiotherapy at NIRS
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND PURPOSE Carbon ion beams provide physical and biological advantages over photons. This study summarizes the experiences of carbon ion radiotherapy at the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences. MATERIALS AND METHODS Between June 1994 and August 2003, a total of 1601 patients with various types of malignant tumors were enrolled in phase I/II dose-escalation studies and clinical phase II studies. All but malignant glioma patients received carbon ion radiotherapy alone with a fraction number and overall treatment time being fixed for each tumor site, given to one field per day and 3 or 4 days per week. In dose-escalation studies, the total dose was escalated by 5 or 10% increments to ensure a safe patient treatment and to determine appropriate dose levels. RESULTS In the initial dose-escalation studies, severe late complications of the recto-sigmoid colon and esophagus were observed in those patients who received high dose levels for prostate, uterine cervix and esophageal cancer. Such adverse effects, however, did shortly disappear as a result of determining safe dose levels and because of improvements in the irradiation method. Carbon ion radiotherapy has shown improvement of outcome for tumor entities: (a) locally advanced head and neck tumors, in particular those with non-squamous cell histology including adenocarcinoma, adenoid cystic carcinoma, and malignant melanoma; (b) early stage NSCLC and locally advanced NSCLC; (c) locally advanced bone and soft tissue sarcomas not suited for surgical resection; (d) locally advanced hepatocellular carcinomas; (e) locally advanced prostate carcinomas, in particular for high-risk patients; (f) chordoma and chondrosarcoma of the skull base and cervical spine, and (g) post-operative pelvic recurrence of rectal cancer. Treatment of malignant gliomas, pancreatic, uterine cervix, and esophageal cancer is being investigated within dose-escalation studies. There is a rationale for the use of short-course RT regimen due to the superior dose localization and the unique biological properties of high-LET beams. This has been proven in treatment of NSCLC and hepatoma, where the fraction number has been successfully reduced to 4-12 fractions delivered within 1-3 weeks. Even for other types of tumors including prostate cancer, bone/soft tissue sarcoma and head/neck tumors, it was equally possible to apply the therapy in much shorter treatment times as compared to conventional RT regimen. CONCLUSION Carbon ion radiotherapy, due to its physical and biologic advantages over photons, has provided improved outcome in terms of minimized toxicity and high local control rates for locally advanced tumors and pathologically non-squamous cell type of tumors. Using carbon ion radiotherapy, hypofractionated radiotherapy with application of larger doses per fraction and a reduction of overall treatment times as compared to conventional radiotherapy was enabled.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy
Kanai, T., Endo, M., Minohara, S., Miyahara, N., Koyama-ito, H., Tomura, H., Matsufuji, N., Futami, Y., Fukumura, A., Hiraoka, T., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00544-6 · Cited by 889
Respiratory gated irradiation system for heavy-ion radiotherapy
Minohara, S., Kanai, T., Endo, M., Noda, K., & Kanazawa, M. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00524-1 · Cited by 457
Tumor therapy with heavy charged particles
Kraft, G. (2000) · Progress in Particle and Nuclear Physics · doi:10.1016/s0146-6410(00)00112-5 · Cited by 454
Irradiation of Mixed Beam and Design of Spread-Out Bragg Peak for Heavy-Ion Radiotherapy
Kanai, T., Furusawa, Y., Fukutsu, K., Itsukaichi, H., Eguchi-Kasai, K., & Ohara, H. (1997) · Radiation Research · doi:10.2307/3579446 · Cited by 422
Efficacy and Safety of Carbon Ion Radiotherapy in Bone and Soft Tissue Sarcomas
Kamada, T., Tsujii, H., Tsuji, H., Yanagi, T., Mizoe, J.-E., Miyamoto, T., Kato, H., Yamada, S., Morita, S., Yoshikawa, K., et al. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.2002.10.050 · Cited by 289
Self-citation(1980) · Elsevier eBooks · doi:10.1016/b978-0-12-576250-2.x5001-8 · Cited by 170
Proton Beams in Radiation Therapy
Suit, H. D., & Urie, M. M. (1992) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/84.3.155 · Cited by 145
High energy neutron treatment for pelvic cancers: study stopped because of increased mortality.
Errington, R. D., Ashby, D., Gore, S., Abrams, K. R., Myint, S., Bonnett, D. E., Blake, S. W., & Saxton, T. (1991) · BMJ · doi:10.1136/bmj.302.6784.1045 · Cited by 62
The use of neutrons in cancer therapy: a historical perspective through the modern era.
Ge, L. (1997) · PubMed · Cited by 43
Medical and other applications of high-energy heavy-ion beams from HIMAC
Murakami, T., Tsujii, H., Furusawa, Y., Andō, K., Kanai, T., Yamada, S., & Kawachi, K. (1997) · Journal of Nuclear Materials · doi:10.1016/s0022-3115(97)00135-9 · Cited by 28
Self-citationSignificance of Fractionated Irradiation for the Biological Therapeutic Gain of Carbon Ions
Koike, S., Ando, K., Uzawa, A., et al. (2002) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a006819 · Cited by 23
Cited by
Heavy-ion tumor therapy: Physical and radiobiological benefits
Schardt, D., Elsässer, T., & Schulz-Ertner, D. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.383 · Cited by 778
Particle Radiation Therapy Using Proton and Heavier Ion Beams
Schulz-Ertner, D., & Tsujii, H. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.7816 · Cited by 622
Self-citationLevin, W. P., Kooy, H., Loeffler, J. S., & DeLaney, T. F. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602754 · Cited by 372
Radiotherapy with beams of carbon ions
Amaldi, U., & Kraft, G. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/8/r04 · Cited by 325
RBE and related modeling in carbon-ion therapy
Karger, C. P., & Peschke, P. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa9102 · Cited by 211
Metadata
- Authors
- Tsujii, H., Mizoe, J.-E., Kamada, T., Baba, M., Kato, S., Kato, H., Tsuji, H., Yamada, S., Yasuda, S., Ohno, T., Yanagi, T., Hasegawa, A., Sugawara, T., Ezawa, H., Kandatsu, S., Yoshikawa, K., Kishimoto, R., & Miyamoto, T.
- Venue
- Radiotherapy and Oncology
- Publisher
- Elsevier BV
- Published
- 2004-12
- Volume
- 73
- Issue
- Suppl.2
- Pages
- S41-S49
- ISSN
- 0167-8140 (ISSN-L)
- OpenAlex
- W1993882008
- Cited by
- 213
- References
- 11
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.