AMS sample handling in Groningen
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The Groningen AMS target laboratory has a capacity of producing 2000 targets annually. Samples are combusted by a CN analyser/mass spectrometer combination. A 25-fold graphitization setup is employed. We emphasize a combination of automation and quality. Backgrounds of better than 45 ka are routinely achieved. Test measurements on contamination, backgrounds and fractionation are reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
14C Background Levels in An Accelerator Mass Spectrometry System
Vogel, J. S., Nelson, D. E., & Southon, J. R. (1987) · Radiocarbon · doi:10.1017/s0033822200043733 · Cited by 286
Cited by
Sample Throughput and Data Quality at the Leibniz-Labor AMS Facility
Nadeau, M.-J., Grootes, P. M., Schleicher, M., Hasselberg, P., Rieck, A., & Bitterling, M. (1997) · Radiocarbon · doi:10.1017/s0033822200018105 · Cited by 232
Status report: The Groningen AMS facility
van der Plicht, J., Wijma, S., Aerts, A. T., Pertuisot, M. H., & Meijer, H. A. J. (2000) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(00)00284-6 · Cited by 166
Self-citationIntCal20 Tree Rings: An Archaeological Swot Analysis
Bayliss, A., Marshall, P., Dee, M. W., Friedrich, M., Heaton, T. J., & Wacker, L. (2020) · Radiocarbon · doi:10.1017/rdc.2020.77 · Cited by 40
“The resultant CO2 was graphitized by hydrogen reduction in the presence of an iron catalyst (Wijma et al. 1996; Aerts-Bijma et al. 1997).”
BackgroundContamination on AMS Sample Targets by Modern Carbon is Inevitable
Paul, D., Been, H. A., Aerts-Bijma, A. T., & Meijer, H. A. J. (2016) · Radiocarbon · doi:10.1017/rdc.2016.9 · Cited by 17
“Such background CO2 samples (~2mg C) were “graphitized” in the routine way, that is, reduced to elemental carbon in the presence of H2 (~2.5 × partial pressure of CO2) and Fe (~2.0–2.5mg) at 600°C (Aerts-Bijma et al. 1997).”
BackgroundSelf-citationWiggle-Matching Using Known-Age Pine from Jermyn Street, London
Tyers, C., Sidell, J., Van der Plicht, J., Marshall, P., Cook, G., Bronk Ramsey, C., & Bayliss, A. (2009) · Radiocarbon · doi:10.1017/s0033822200055788 · Cited by 13
“Samples dated by AMS at the Rijksuniversiteit Groningen were processed using the acid/alkali/acid protocol (Mook and Waterbolk 1985), combusted to carbon dioxide and graphitized as described by Aerts-Bijma et al. (1997, 2001), and then measured as described by van der Plicht et al. (2000).”
Method
Metadata
- Authors
- Aerts-Bijma, A. T., Meijer, H. A. J., & van der Plicht, J.
- Venue
- Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Publisher
- Elsevier BV
- Published
- 1997-03
- Volume
- 123
- Issue
- 1-4
- Pages
- 221-225
- ISSN
- 0168-583X (ISSN-L)
- OpenAlex
- W2035410609
- Cited by
- 77
- References
- 1
- FWCI
- 5.32
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AMS sample handling in Groningen. https://app.cochat.ai/papers/10.1016/s0168-583x(96)00672-6
- The paper
- Aerts-Bijma, A. T., Meijer, H. A. J., & van der Plicht, J. (1997). AMS sample handling in Groningen. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. https://doi.org/10.1016/s0168-583x(96)00672-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.