Direct orthogonal signal correction
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Orthogonal signal correction of near-infrared spectra
Wold, S., Antti, H., Lindgren, F., & Öhman, J. (1998) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(98)00109-9 · Cited by 1,089
Matrix Analysis for Statistics.
Kafadar, K., & Schott, J. R. (1997) · Journal of the American Statistical Association · doi:10.2307/2965451 · Cited by 919
Sjöblom, J., Svensson, O., Josefson, M., Kullberg, H., & Wold, S. (1998) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(98)00112-9 · Cited by 296
Andersson, C. A. (1999) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(98)00158-0 · Cited by 147
Cited by
OPLS discriminant analysis: combining the strengths of PLS-DA and SIMCA classification
Bylesjö, M., Rantalainen, M., Cloarec, O., Nicholson, J. K., Holmes, E., & Trygg, J. (2006) · Journal of Chemometrics · doi:10.1002/cem.1006 · Cited by 1,475
“Despite the fairly unambiguous concept of OSC, a multitude of implementations occur in the literature [14–16].”
BackgroundDunn, W. B., Broadhurst, D. I., Atherton, H. J., Goodacre, R., & Griffin, J. L. (2011) · Chem. Soc. Rev. · doi:10.1039/b906712b · Cited by 860
Transfer of multivariate calibration models: a review
Feudale, R. N., Woody, N. A., Tan, H., Myles, A. J., Brown, S. D., & Ferré, J. (2002) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(02)00085-0 · Cited by 555
Breaking with trends in pre-processing?
Engel, J., Gerretzen, J., Szymańska, E., Jansen, J. J., Downey, G., Blanchet, L., & Buydens, L. M. C. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.04.015 · Cited by 529
Signal and Data Processing for Machine Olfaction and Chemical Sensing: A Review
Marco, S., & Gutierrez-Galvez, A. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2192920 · Cited by 341
O2‐PLS, a two‐block (X–Y) latent variable regression (LVR) method with an integral OSC filter
Trygg, J., & Wold, S. (2003) · Journal of Chemometrics · doi:10.1002/cem.775 · Cited by 339
Background removal from spectra by designing and minimising a non-quadratic cost function
Mazet, V., Carteret, C., Brie, D., Idier, J., & Humbert, B. (2005) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.10.003 · Cited by 316
Multivariate class modeling for the verification of food-authenticity claims
Oliveri, P., & Downey, G. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.02.005 · Cited by 275
Robust Early Pregnancy Prediction of Later Preeclampsia Using Metabolomic Biomarkers
Kenny, L. C., Broadhurst, D. I., Dunn, W., Brown, M., North, R. A., McCowan, L., Roberts, C., Cooper, G. J. S., Kell, D. B., & Baker, P. N. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.157297 · Cited by 269
Lu, Y., Saeys, W., Kim, M., Peng, Y., & Lu, R. (2020) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2020.111318 · Cited by 263
O2‐PLS for qualitative and quantitative analysis in multivariate calibration
Trygg, J. (2002) · Journal of Chemometrics · doi:10.1002/cem.724 · Cited by 238
A review on spectral data preprocessing techniques for machine learning and quantitative analysis
Yan, C. (2025) · iScience · doi:10.1016/j.isci.2025.112759 · Cited by 193
“The Direct OSC (DOSC) 137 algorithm accomplishes this through a three-step projection and decomposition process.”
Resting-state cortical connectivity predicts motor skill acquisition
Wu, J., Srinivasan, R., Kaur, A., & Cramer, S. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.01.026 · Cited by 150
“Direct orthogonal signal correction (Westerhuis et al., 2001) was then used to remove the component of the predicting data (coherence) that was most orthogonal to the behavioral data (% Improvement).”
Metadata
- Authors
- Westerhuis, J. A., de Jong, S., & Smilde, A. K.
- Venue
- Chemometrics and Intelligent Laboratory Systems
- Publisher
- Elsevier BV
- Published
- 2001-04
- Volume
- 56
- Issue
- 1
- Pages
- 13-25
- ISSN
- 0169-7439 (ISSN-L)
- OpenAlex
- W1973253257
- Cited by
- 317
- References
- 5
- FWCI
- 15.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.