The DOI matches its Crossref record.
Clinical and electrophysiological differences between patients with arrhythmogenic right ventricular dysplasia and right ventricular outflow tract tachycardia
Abstract
AIMS: Radiofrequency catheter ablation is considered first line treatment for symptomatic patients with right ventricular outflow tract tachycardia (RVOT). The role of ablation in arrhythmogenic right ventricular dysplasia (ARVD) is more limited. As such, differentiating between the two conditions is essential. METHODS AND RESULTS: This study compared non-invasive findings, magnetic resonance images (MRI), invasive electrophysiological characteristics, results of ablation and long-term outcome in 50 consecutive patients with RVOT (33) or ARVD (17). Structural abnormalities were uniform in the ARVD group; in addition 18 (54%) of the RVOT tachycardia group had MRI abnormalities. At electrophysiological study the tachycardia in the ARVD group displayed features of re-entry in over 80%, but behaved with a triggered automatic basis in 97% with RVOT. Ablation was complete or partial success in 12 (71%) patients with ARVD and ventricular tachycardia (VT) recurred in eight (48%). In the RVOT patients, ablation was a complete success in 97% with recurrent VT in 6%. Long-term success in the RVOT patients was 95% in both patients with and without MRI abnormalities. CONCLUSIONS: Electrophysiological characterization can differentiate ARVD from RVOT. The finding of abnormalities on MRI does not have any bearing on arrhythmia mechanism, acute or long-term success of RFA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Corrado, D., van Tintelen, P. J., McKenna, W. J., Hauer, R. N. W., Anastastakis, A., Asimaki, A., Basso, C., Bauce, B., Brunckhorst, C., Bucciarelli-Ducci, C., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz669 · Cited by 366
Niwano, S., Wakisaka, Y., Niwano, H., Fukaya, H., Kurokawa, S., Kiryu, M., Hatakeyama, Y., & Izumi, T. (2009) · Heart · doi:10.1136/hrt.2008.159558 · Cited by 299
Metadata
- Authors
- O'Donnell, D.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-05
- Volume
- 24
- Issue
- 9
- Pages
- 801-810
- ISSN
- 0195-668X (ISSN-L)
- OpenAlex
- W2145698578
- Cited by
- 171
- References
- 0
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical and electrophysiological differences between patients with arrhythmogenic right ventricular dysplasia and right ventricular outflow tract tachycardia. https://app.cochat.ai/papers/10.1016/s0195-668x(02)00654-1
- The paper
- O'Donnell, D. (2003). Clinical and electrophysiological differences between patients with arrhythmogenic right ventricular dysplasia and right ventricular outflow tract tachycardia. European Heart Journal. https://doi.org/10.1016/s0195-668x(02)00654-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.