The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Exercise-induced myocardial ischaemia detected by cardiopulmonary exercise testing
Abstract
BACKGROUND: The objective of the study was to identify the parameter(s) of cardiopulmonary exercise testing (CPET) that can detect exercise-induced myocardial ischaemia (EIMI), and to determine its diagnostic accuracy for identifying patients with coronary artery disease (CAD). METHODS AND RESULTS: We prospectively studied 202 consecutive patients (173 men, 29 women, mean age 55.7+/-10.8 years) with documented CAD. All patients underwent an incremental exercise stress testing (ECG-St) with breath-by-breath gas exchange analysis, followed by a 2-day stress/rest gated SPECT myocardial scintigraphy (GSMS) as the gold standard for ischaemia detection. ROC analysis selected a two-variable model-O(2)pulse flattening duration, calculated from the onset of myocardial ischaemia to peak exercise, and deltaVO(2)/deltawork rate slope-to predict EIMI by CPET. GSMS identified 140 patients with reversible myocardial defects, with a Summed Difference Score (SDS) of 9.7+/-2.8, and excluded EIMI in 62 (SDS 1.3+/-1.6). ECG-St had low sensitivity (46%) and specificity (66%) to diagnose EIMI as compared with CPET (87% and 74%, respectively). CONCLUSIONS: The addition of gas exchange analysis improves the diagnostic accuracy of standard ECG stress testing in identifying EIMI. A two-variable model based on O(2)pulse flattening duration and deltaVO(2)/deltawork rate slope had the highest predictive ability to identify EIMI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Physiologic Evaluation of the Patient With Lung Cancer Being Considered for Resectional Surgery
Brunelli, A., Kim, A. W., Berger, K. I., & Addrizzo-Harris, D. J. (2013) · Chest · doi:10.1378/chest.12-2395 · Cited by 910
Guazzi, M., Adams, V., Conraads, V., Halle, M., Mezzani, A., Vanhees, L., Arena, R., Fletcher, G. F., Forman, D. E., Kitzman, D. W., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31826fb946 · Cited by 822
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
Metadata
- Authors
- Belardinelli, R.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-07
- Volume
- 24
- Issue
- 14
- Pages
- 1304-1313
- ISSN
- 0195-668X (ISSN-L)
- OpenAlex
- W2061128143
- Cited by
- 256
- References
- 1
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exercise-induced myocardial ischaemia detected by cardiopulmonary exercise testing. https://app.cochat.ai/papers/10.1016/s0195-668x(03)00210-0
- The paper
- Belardinelli, R. (2003). Exercise-induced myocardial ischaemia detected by cardiopulmonary exercise testing. European Heart Journal. https://doi.org/10.1016/s0195-668x(03)00210-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.