The DOI matches its Crossref record.
Importance of air quality and related factors in the prevention of infection in orthopaedic implant surgery
Abstract
Small numbers of organisms can cause orthopaedic implant infections, which give rise to a considerable degree of morbidity and also mortality. The periprosthetic infection rates have been shown to correlate with the number of airborne bacteria within 30 cm of the wound. This is influenced by factors such as the number of operating theatre personnel, their clothing and the type of ventilation system used. Guidance on routine bacteriological monitoring of ultraclean air theatres, based on the Department of Health document Health Technical Memorandum 2025, is discussed. Factors important in minimizing the number of postoperative implant infections such as the use of ultraclean air, ultraviolet radiation, different types of surgical clothing, prophylactic antibiotics and host-related factors are also discussed. The importance of proper scientific investigation into the effectiveness of practical preventative measures in the operating room is emphasized.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Periprosthetic infection rates correlate with the number of airborne bacteria within the wound.
“it has been demonstrated that periprosthetic infection rates correlate with the number of airborne bacteria within the wound [16]”
From Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres (2012) · cites this paper as [16]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 59
- Charnley, 1969, Postoperative infection in total prosthetic replacement arthroplasty of the hip joint, Br J Surg, 56, 641, 10.1002/bjs.1800560902 · DOI
- Lidwell, 1982, The effect of ultraclean air in operating rooms on deep sepsis in the joint after hip or knee replacement: a randomised study, Br Med J, 285, 10, 10.1136/bmj.285.6334.10 · DOI
- Lidwell, 1988, Air, antibiotics and sepsis in replacement joints, J Hosp Infect, 11, 18, 10.1016/0195-6701(88)90020-5 · DOI
- Strachan, 1995, The prevention of orthopaedic and vascular graft infections, J Hosp Infect, 30, 54, 10.1016/0195-6701(95)90006-3 · DOI
- Bartzokas, 1994, Relation between mouth and haematogenous infection in total joint replacements, Br Med J, 309, 506, 10.1136/bmj.309.6953.506 · DOI
- Charnley, 1972, Postoperative infection after total hip replacement with special reference to air contamination in the operating room, Clin Orthop, 87, 167, 10.1097/00003086-197209000-00020 · DOI · Paper page
- Taylor, 1995, Wound disinfection with ultraviolet radiation, J Hosp Infect, 30, 85, 10.1016/0195-6701(95)90148-5 · DOI
- Lidwell, 1983, Airborne contamination of wounds in joint replacement operations: The relationship to sepsis rates, J Hosp Infect, 4, 111, 10.1016/0195-6701(83)90041-5 · DOI
- Johnson, 1986, The outcome of infected arthroplasty of the knee, J Bone Joint Surg, 68B, 289, 10.1302/0301-620X.68B2.3958017 · DOI
- Berry, 1991, The use of bone allografts in two stage reconstruction after failure of hip replacements due to infection, J Bone Joint Surg, 74A, 1460, 10.2106/00004623-199173100-00003 · DOI
- Fitzgerald, 1992, Total hip arthroplasty sepsis—prevention and diagnosis in complications of total hip arthroplasty, Orthop Clin North Am, 23, 259, 10.1016/S0030-5898(20)31736-3 · DOI
- Malchau, 1993, Prognosis of total hip replacement in Sweden, Acta Orthop Scand, 64, 497, 10.3109/17453679308993679 · DOI
- Whyte, 1982, The importance of airborne bacterial contamination of wounds, J Hosp Infect, 3, 123, 10.1016/0195-6701(82)90004-4 · DOI
- Ayliffe, 1967, Wound infections acquired from a disperser of an unusual strain of Staphylococcus aureus, J Clin Path, 20, 195, 10.1136/jcp.20.2.195 · DOI
- Ahl, 1987, Air contamination during hip and knee arthroplasties. Horizontal laminar flow randomized vs conventional ventilation, Acta Orthop Scand, 66, 17, 10.3109/17453679508994632 · DOI
- Whyte, 1973, A bacteriological evaluation of laminar-flow systems for orthopaedic surgery, J Hyg Camb, 71, 559, 10.1017/S0022172400046544 · DOI
- Lidwell, 1987, Ultraclean air and antibiotics for prevention of post-operative infection. A multicentre study of 8052 joint replacement operations, Acta Orthop Scand, 58, 4, 10.3109/17453678709146334 · DOI
- Humphreys, 1995, Survey of operating theatres in Great Britain and Ireland, J Hosp Infect, 30, 245, 10.1016/0195-6701(95)90258-9 · DOI
- Holton, 1993, Commissioning operating theatres, J Hosp Infect, 23, 153, 10.1016/0195-6701(93)90019-V · DOI
- Whyte, 1983, Suggested bacteriological standard for air in ultraclean operating rooms, J Hosp Infect, 4, 133, 10.1016/0195-6701(83)90042-7 · DOI
- Fox, 1995, Theatre air sampling—ignorance is bliss!, J Hosp Infect, 30, 80, 10.1016/0195-6701(95)90256-2 · DOI
- Fox, 1996, Theatre air sampling—once a year is not enough, J Hosp Infect, 32, 319, 10.1016/S0195-6701(96)90042-0 · DOI
- Carlsson, 1986, Ultraviolet radiation and air contamination during total hip replacement, J Hosp Infect, 7, 176, 10.1016/0195-6701(86)90061-7 · DOI
- Golder, 1980, Ultraviolet light for the control of airborne bacteria in the operating room, Ann New York Acad Sci, 353, 271, 10.1111/j.1749-6632.1980.tb18930.x · DOI
- Berg, 1989, Shortwave ultraviolet radiation in operating rooms, J Bone Joint Surg, 71B, 483, 10.1302/0301-620X.71B3.2656721 · DOI
- Berg, 1991, Ultraviolet radiation compared to an ultraclean air enclosure: Comparison of air bacterial counts in operating rooms, J Bone Joint Surg, 73B, 811, 10.1302/0301-620X.73B5.1894672 · DOI
- Lowell, 1980, Ultraviolet radiation and reduction in deep wound infection following hip and knee arthroplasty, Ann New York Acad Sci, 353, 285, 10.1111/j.1749-6632.1980.tb18931.x · DOI
- Taylor, 1995, Wound disinfection with ultraviolet radiation, J Hosp Infect, 30, 85, 10.1016/0195-6701(95)90148-5 · DOI
- Hambraeus, 1988, Aerobiology in the operating room — a review, J Hosp Infect, 11, 68, 10.1016/0195-6701(88)90169-7 · DOI
- Noble, 1975, Dispersal of skin microorganisms, Br J Dermatol, 93, 477, 10.1111/j.1365-2133.1975.tb06527.x · DOI
- Whyte, 1990, An investigation of occlusive polyester surgical clothing, J Hosp Infect, 15, 363, 10.1016/0195-6701(90)90093-4 · DOI
- Whyte, 1976, Bacterial dispersion in relation to operating room clothing, J Hyg Lond, 76, 367, 10.1017/S0022172400055297 · DOI
- Hubble, 1996, Clothing in laminar-flow operating theatres, J Hosp Infect, 32, 1, 10.1016/S0195-6701(96)90159-0 · DOI
- Babb, 1995, Risk of airborne transmission in an operating theatre containing four ultraclean air units, J Hosp Infect, 31, 159, 10.1016/0195-6701(95)90062-4 · DOI
- Salvati, 1982, Infection rates after 3175 total hip and knee replacements performed with and without a horizontal unidirectional filtered air-flow system, J Bone Joint Surg Am, 64, 525, 10.2106/00004623-198264040-00007 · DOI
- Taylor, 1993, Infection and interposition between ultraclean air source and wound, J Bone Joint Surg Br, 75B, 503, 10.1302/0301-620X.75B3.8496233 · DOI
- Blomgren, 1990, Reduction of contamination at total hip replacement by special working clothes, J Bone Joint Surg Br, 72B, 985, 10.1302/0301-620X.72B6.2246302 · DOI
- Sanzen, 1990, Air contamination during total hip arthroplasty in an ultraclean air enclosure using different types of staff clothing, J Arthroplasty, 5, 127, 10.1016/S0883-5403(06)80231-7 · DOI
- Scheibel, 1991, Bacterial contamination of air and surgical wounds during joint replacement operations. Comparison of two different types of staff clothing, J Hosp Infect, 19, 167, 10.1016/0195-6701(91)90220-3 · DOI
- Quesnel, 1975, The efficiency of surgical masks of varying design and composition, Br J Surg, 62, 936, 10.1002/bjs.1800621203 · DOI
- Davis, 1991, Filtration efficiency of surgical face masks: the need for meaningful standards, Am J Infect Control, 19, 16, 10.1016/0196-6553(91)90156-7 · DOI
- Belkin, 1997, The evolution of the surgical mask: filtering efficiency versus effectiveness, Infect Control Hosp Epidemiol, 18, 49, 10.1086/647501 · DOI
- Ericson, 1973, Cloxacillin in the prophylaxis of postoperative infections of the hip, J Bone Joint Surg Am, 55, 808, 10.2106/00004623-197355040-00015 · DOI
- Carlsson, 1977, Prophylactic antibiotics against early and late deep infections after total hip replacements, Acta Orthop Scand, 48, 405, 10.3109/17453677708992017 · DOI
- Hill, 1981, Prophylactic cefazolin versus placebo in total hip replacement. Report of a multicentre double-blind trial, Lancet, 1, 795, 10.1016/S0140-6736(81)92678-7 · DOI
- Klenerman, 1991, Combined prophylactic effect of ultraclean air and cefuroxime for reducing infection in prosthetic surgery, Acta Orthop Belg, 57, 19
- Norden, 1991, Antibiotic prophylaxis in orthopaedic surgery, Rev Infect Dis, 13, S842, 10.1093/clinids/13.Supplement_10.S842 · DOI
- Josefsson, 1981, Systemic antibiotics and gentamicin containing bone cement in the prophylaxis infections in total hip arthroplasty, Clin Orthop, 159, 194, 10.1097/00003086-198109000-00027 · DOI
- Rogers, 1993, Fabrication and pharmacokinetic release profile of antibiotic impregnated calcium phosphate ceramic: in vitro study, Trans Soc Biomater, 16, 256
- Stratton, 1974, Implant infection in orthopaedics, Med J Austr, 2, 90, 10.5694/j.1326-5377.1974.tb93624.x · DOI
- Cheatle, 1991, The effect of chronic orthopaedic infection on quality of life, Orthop Clin North Am, 22, 539, 10.1016/S0030-5898(20)31682-5 · DOI
- An, 1996, Prevention of sepsis in total joint arthroplasty, J Hosp Infect, 33, 93, 10.1016/S0195-6701(96)90094-8 · DOI
- Gristina, 1984, Bacterial adherence to biomaterials: the clinical significance of its role in sepsis, Trans Soc Biomater, 7, 175
- Elson, 1977, Bacterial infection and acrylic cement in the rat, J Bone Joint Surg, 59B, 452, 10.1302/0301-620X.59B4.925056 · DOI
- Taylor, 1992, Assessment of airborne bacterial contamination of clean wounds: results in a tissue model, J Hosp Infect, 22, 241, 10.1016/0195-6701(92)90048-Q · DOI
- Benediktsdottir, 1983, Isolation of anaerobic and aerobic bacteria from clean surgical wounds: an experimental and clinical study, J Hosp Infect, 4, 141, 10.1016/0195-6701(83)90043-9 · DOI
- Lilly, 1970, Effects of adhesive drapes on contamination of operation wounds, Lancet, 2, 431, 10.1016/S0140-6736(70)90053-X · DOI
- Hamer, 1975, Quantitative bacterial analysis of comparative wound irrigations, Ann Surg, 181, 819, 10.1097/00000658-197506000-00010 · DOI
- Brown, 1978, Evaluation of wound irrigation by pulsatile jet and conventional methods, Ann Surg, 2, 170, 10.1097/00000658-197802000-00013 · DOI
Cited by
Sorted by citations
Environmental controls in operating theatres
Dharan, S., & Pittet, D. (2002) · Journal of Hospital Infection · doi:10.1053/jhin.2002.1217 · Cited by 282
Napoli, C., Marcotrigiano, V., & Montagna, M. T. (2012) · BMC Public Health · doi:10.1186/1471-2458-12-594 · Cited by 244
Metadata
- Authors
- Gosden, P. E., MacGowan, A. P., & Bannister, G. C.
- Affiliations
- Southmead Hospital (GB)
- Venue
- Journal of Hospital Infection
- Publisher
- Elsevier BV
- Published
- 1998-07
- Volume
- 39
- Issue
- 3
- Pages
- 173-180
- ISSN
- 0195-6701 (ISSN-L)
- OpenAlex
- W2096045817
- Cited by
- 118
- References
- 0
- Citations by year
- 2025: 4 · 2024: 2 · 2023: 2 · 2022: 5 · 2021: 3 · 2020: 6 · 2019: 6 · 2018: 6 · 2017: 8 · 2016: 6 · 2015: 7 · 2014: 3 · 2013: 5 · 2012: 8
- FWCI
- 0.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hospital Infection (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Surgical site infection prevention
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Health Sciences › Medicine › Surgery › Orthopedic Infections and Treatments
- Keywords
- orthopedic implant infection, periprosthetic joint infection, airborne bacteria, bacteriological monitoring, ultraviolet radiation, antibiotic prophylaxis, infection control
- MeSH terms
- Air Microbiology, Cross Infection, United Kingdom, Humans, Operating Rooms, Orthopedics, Protective Clothing, Risk Factors, Ultraviolet Therapy, Prosthesis-Related Infections, Air Pollution, Indoor, Antibiotic Prophylaxis, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›