CoChat

Evaluación y validación de los monitores Omron Hem 705 CP y Hem 706/711 para automedidas de presión arterial

Open access
Artigao, L.M., Llavador, J.J., Puras, A., López Abril, J., Rubio, M.M., Torres, C., Vidal, A., Sanchis, C., Divisón, J.A., Naharro, F., Caldevilla, D., Fuentes, G. · 2000 · Atención Primaria
Cited by 73

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objetivos Validar 2 monitores semiautomaticos (Omron 705 y 706/711) para la medida de la presion arterial, y su comportamiento en presiones arteriales limites, de acuerdo con los protocolos de la British Hipertension Society (BHS) y con los criterios de precision de la Association for the Advancement of Medical Instrumentation (AAMI). Diseno Protocolo de la BHS para la validacion de monitores semiautomaticos de medida de la presion arterial. Emplazamiento Atencion primaria. Centro de Salud Zona III de Albacete. Participantes Noventa y cinco sujetos para el monitor 706/711 y 100 para el 705. Resultados Los 2 monitores superaron la validacion segun el protocolo de la BHS (705 con grado A para presiones arteriales sistolicas y diastolicas, 706/711 con grado B para sistolicas y A para las diastolicas); ambos monitores superaron tambien los criterios de precision exigidos por la AAMI. Al analizar el comportamiento de los monitores por subgrupos de medidas de presion arterial (altas, medias y bajas), el 705 en sistolicas > 160 mmHg supero con grado B el protocolo BHS, pero no paso los criterios de la AAMI (DE, 8,5), aunque las diferencias entre las medias de los 2 observadores de las columnas de Hg y la media del 705 fue –0,1 m Hg, el resto de subgrupos de presion arterial obtuvieron un grado A de la BHS y superaron los criterios exigidos por la AAMI. El 706/711 supero, a su vez, en todos los subgrupos de presion arterial el protocolo de la BHS, obtuvo un grado B para las diastolicas de 80-100 y > 100, y para sistolicas > 160; en el resto de subgrupos obtuvo un grado A; ademas cumplio en cada subgrupo los criterios de precision exigidos por la AAMI. Conclusiones En funcion de estos resultados puede concluirse que ambos monitores semiautomaticos superaron satisfactoriamente la gradacion de la BHS y los criterios de precision exigidos por la AAMI, por lo que pueden recomendarse para su uso clinico.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0212-6567(00)78470-8

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 73

Metadata

Authors
Artigao, L. M., Llavador, J. J., Puras, A., López Abril, J., Rubio, M. M., Torres, C., Vidal, A., Sanchis, C., Divisón, J. A., Naharro, F., Caldevilla, D., & Fuentes, G.
Venue
Atención Primaria
Publisher
Elsevier BV
Published
2000
Volume
25
Issue
2
Pages
96-102
ISSN
0212-6567 (ISSN-L)
OpenAlex
W2033373225
Cited by
73
References
2
FWCI
3.76
Type
journal article
Language
es
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluación y validación de los monitores Omron Hem 705 CP y Hem 706/711 para automedidas de presión arterial. https://app.cochat.ai/papers/10.1016/s0212-6567(00)78470-8
The paper
Artigao, L. M., Llavador, J. J., Puras, A., López Abril, J., Rubio, M. M., Torres, C., Vidal, A., Sanchis, C., Divisón, J. A., Naharro, F., Caldevilla, D., & Fuentes, G. (2000). Evaluación y validación de los monitores Omron Hem 705 CP y Hem 706/711 para automedidas de presión arterial. Atención Primaria. https://doi.org/10.1016/s0212-6567(00)78470-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.