Automated blood pressure measurement in atrial fibrillation: a systematic review and meta-analysis

Stergiou, George S., Kollias, Anastasios, Destounis, Antonios, Tzamouranis, Dimitrios·2012·Journal of Hypertension

Abstract

OBJECTIVE: The measurement of blood pressure in atrial fibrillation is considered as difficult and uncertain, and current guidelines recommend the use of the auscultatory method. The accuracy of automated blood pressure monitors in atrial fibrillation remains controversial. METHOD: A systematic review and meta-analysis was performed of studies comparing automated (oscillometric or automated Korotkov) versus manual auscultatory blood pressure measurements (mercury or aneroid sphygmomanometer) in patients with sustained atrial fibrillation. RESULTS: Twelve validations were analyzed (566 patients; five home, three ambulatory and three office devices). Pooled correlation coefficients between automated and manual blood pressure measurements were stronger for SBP than DBP (r = 0.89 versus 0.76, P < 0.001). Automated measurements were higher than manual measurements [pooled average SBP difference 0.5 mmHg, 95% confidence interval (CI) -0.9, 1.9; DBP 2.5 mmHg, 95%CI -0.6, 5.7). The mean difference was within 5 mmHg in six and four (SBP and DBP, respectively) of six validations. The SD of mean difference was within 8 mmHg in two and three (SBP and DBP, respectively) of four validations. The proportion of absolute automated-manual differences within 5 mmHg was at least 65% in four and two (SBP and DBP, respectively) of eight validations. Three studies showed no impact of heart rate on the automated-manual blood pressure differences. CONCLUSION: There is limited evidence and significant heterogeneity in the studies that validated automated blood pressure monitors in atrial fibrillation. These monitors appear to be accurate in measuring SBP but not DBP. Given that atrial fibrillation is common in the elderly, in whom systolic hypertension is more common and important than diastolic hypertension, automated monitors appear to be appropriate for self-home but not for office measurement.

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e32835850d7

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

2 of the 31 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Stergiou, G. S., Kollias, A., Destounis, A., & Tzamouranis, D.
Affiliations
Sotiria General Hospital (GR)
Corresponding author
Stergiou, George S.
Venue
Journal of Hypertension
Published
2012-11
Volume
30
Issue
11
Pages
2074-2082
ISSN
0263-6352 (ISSN-L)
OpenAlex
W1967096675
Cited by
120
References
31
Citations by year
2026: 6 · 2024: 4 · 2023: 4 · 2022: 9 · 2021: 9 · 2020: 10 · 2019: 14 · 2018: 9 · 2017: 15 · 2016: 13 · 2015: 8 · 2014: 6 · 2013: 11 · 2012: 2
FWCI
5.56
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
atrial fibrillation, automated blood pressure measurement, oscillometric blood pressure monitor, auscultatory blood pressure measurement, systolic blood pressure, diastolic blood pressure, measurement accuracy, home blood pressure monitoring, ambulatory blood pressure monitoring, office blood pressure measurement
MeSH terms
Analysis of Variance, Atrial Fibrillation, Automation, Blood Pressure Determination, Heart Rate, Humans, Hypertension, Systole, Reproducibility of Results, Blood Pressure Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review