Hypertension is Not Adequately Controlled in Hemodialysis Patients
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
To examine the adequacy of hypertension control, we monitored the blood pressure (BP) of 53 hemodialysis patients who received treatment for hypertension. BP measurement using an ambulatory BP monitor began 1 hour before dialysis and continued every 30 to 60 minutes for 48 hours until the next dialysis. Diet, medications including antihypertensive drugs, and hemodialysis prescription were not changed during this study. Each patient had a mean of 68 BP measurements during the monitoring period. Mean (±SD) systolic and diastolic BP levels of all patients over 48 hours were 158.6 ± 22.7 mm Hg and 88.7 ± 16.6 mm Hg, respectively, without diurnal variations. In these, BP loads (the percentage of systolic BP exceeding 150 mm Hg and diastolic BP exceeding 90 mm Hg) were 58.4% and 39.4%, respectively, suggesting that hypertension was inadequately controlled for more than half of the study period. Eight patients (15%) maintained BP within normal ranges at all times. All patients lost weight (2.9 ± 0.9 kg) at the end of dialysis by ultrafiltration. However, only 27 patients (51%) had a greater than 5% decrease in mean arterial BP postdialysis, which returned to predialysis levels within 12 to 24 hours. Reduction of BP postdialysis was significantly more common among black patients (72%) than white patients (30%) ( P < 0.01). However, there was no difference in age, cause of kidney disease, amount of ultrafiltration, and BP loads between those whose BP decreased and those whose did not. BP monitoring was repeated in eight patients, 2 to 3 months after adjustment of their antihypertensive regimens. In the repeat study, systolic BP loads were 18.4%, compared with 77.1 % in the previous study. ( P < 0.001). In summary, (1) hypertension is not adequately controlled in the majority of hemodialysis patients despite antihypertensive treatment; (2) only half of hypertension patients have a decrease in BP at the end of dialysis, which returns to predialysis levels between 12 and 24 hours; (3) reduction of BP in response to ultrafiltration is significantly more common in blacks than whites, suggesting a different mechanism is operational in maintaining hypertension among races; (4) circadian rhythm in BP is not preserved; and (5) continuous ambulatory BP monitoring helps improve hypertension control. We conclude that a considerable number of hemodialysis patients who are treated for chronic hypertension do not have adequate control of hypertension. This finding may explain, at least partially, why cardiac and cerebrovascular disease remain the major causes of death in dialysis patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circadian variation of blood-pressure
Millar-Craig, M., Bishop, C., & Raftery, E. B. (1978) · The Lancet · doi:10.1016/s0140-6736(78)92998-7 · Cited by 1,293
Parati, G., Pomidossi, G., Albini, F., Malaspina, D., & Mancia, G. (1987) · Journal of Hypertension · doi:10.1097/00004872-198702000-00013 · Cited by 952
Hemodynamic characteristics of sodium-sensitive human subjects.
Sullivan, J. M., Prewitt, R. L., Ratts, T. E., Josephs, J. A., & Connor, M. J. (1987) · Hypertension · doi:10.1161/01.hyp.9.4.398 · Cited by 97
Self-citation
Cited by
Reverse epidemiology of cardiovascular risk factors in maintenance dialysis patients
Kalantar-Zadeh, K., Block, G., Humphreys, M. H., & Kopple, J. D. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00803.x · Cited by 1,247
“U” curve association of blood pressure and mortality in hemodialysis patients
Zager, P. G., Nikolic, J., Brown, R. H., Campbell, M. A., Hunt, W. C., Peterson, D., Van Stone, J., Levey, A., Meyer, K. B., Klag, M. J., et al. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.00005.x · Cited by 662
Agarwal, R., Nissenson, A. R., Batlle, D., Coyne, D. W., Trout, J. R., & Warnock, D. G. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00366-8 · Cited by 480
Port, F. K., Hulbert-Shearon, T. E., Wolfe, R. A., Bloembergen, W. E., Golper, T. A., Agodoa, L. Y. C., & Young, E. W. (1999) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(99)70188-5 · Cited by 451
Management of Hypertension in Chronic Kidney Disease
Pugh, D., Gallacher, P. J., & Dhaun, N. (2019) · Drugs · doi:10.1007/s40265-019-1064-1 · Cited by 401
Assessment of Dry Weight in Hemodialysis: An Overview
JAEGER, J. Q., & MEHTA, R. L. (1999) · Journal of the American Society of Nephrology · doi:10.1681/asn.v102392 · Cited by 310
Intradialytic Exercise in Hemodialysis Patients: A Systematic Review and Meta-Analysis
Sheng, K., Zhang, P., Chen, L., Cheng, J., Wu, C., & Chen, J. (2014) · American Journal of Nephrology · doi:10.1159/000368722 · Cited by 260
Home Blood Pressures Are of Greater Prognostic Value than Hemodialysis Unit Recordings
Alborzi, P., Patel, N., & Agarwal, R. (2007) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.02250507 · Cited by 248
Agarwal, R., Peixoto, A. J., Santos, S. F. F., & Zoccali, C. (2006) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01891105 · Cited by 245
Evidence for high risk of cerebral hemorrhage in chronic dialysis patients
Iseki, K., Kinjo, K., Kimura, Y., Osawa, A., & Fukiyama, K. (1993) · Kidney International · doi:10.1038/ki.1993.352 · Cited by 222
“high or low [18, 19].”
Hemodialysis-associated hypertension: Pathophysiology and therapy
Hörl, M. P., & Hörl, W. H. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.30542 · Cited by 215
Importance of blood pressure control in hemodialysis patient survival
Mazzuchi, N., Carbonell, E., & Fernandez-Cean, J. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00388.x · Cited by 183
Blood pressure control in dialysis patients: Importance of the lag phenomenon
Charra, B., Bergstrom, J., & Scribner, B. (1998) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(98)70147-7 · Cited by 173
Metadata
- Authors
- Cheigh, J. S., Milite, C., Sullivan, J. F., Rubin, A. L., & Stenzel, K. H.
- Venue
- American Journal of Kidney Diseases
- Publisher
- Elsevier BV
- Published
- 1992-05
- Volume
- 19
- Issue
- 5
- Pages
- 453-459
- ISSN
- 0272-6386 (ISSN-L)
- OpenAlex
- W2081937083
- Cited by
- 182
- References
- 4
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.