The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Assessment of Dry Weight in Hemodialysis: An Overview
Abstract
Abstract.: Fluid balance is an integral component of hemodialysis treatments to prevent under- or overhydration, both of which have been demonstrated to have significant effects on intradialytic morbidity and long-term cardiovascular complications. Fluid removal is usually achieved by ultrafiltration to achieve a clinically derived value for “dry weight.” Unfortunately, there is no standard measure of dry weight and as a consequence it is difficult to ascertain adequacy of fluid removal for an individual patient. Additionally, there is a lack of information on the effect of ultrafiltration on fluid shifts in the extracellular and intracellular fluid spaces. It is evident that a better understanding of both interdialytic fluid status and fluid changes during hemodialysis is required to develop a precise measure of fluid balance. This article describes the current status of dry weight estimation and reviews emerging techniques for evaluation of fluid shifts. Additionally, it explores the need for a marker of adequacy for fluid removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Cited by
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Importance of Whole-Body Bioimpedance Spectroscopy for the Management of Fluid Balance
Wabel, P., Chamney, P., Moissl, U., & Jirka, T. (2009) · Blood Purification · doi:10.1159/000167013 · Cited by 375
Bioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Dry-Weight Reduction in Hypertensive Hemodialysis Patients (DRIP): A Randomized, Controlled Trial
Agarwal, R., Alborzi, P., Satyan, S., & Light, R. P. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.125674 · Cited by 349
Volume overload correlates with cardiovascular risk factors in patients with chronic kidney disease
Hung, S.-C., Kuo, K.-L., Peng, C.-H., Wu, C.-H., Lien, Y.-C., Wang, Y.-C., & Tarng, D.-C. (2014) · Kidney International · doi:10.1038/ki.2013.336 · Cited by 254
Metadata
- Authors
- JAEGER, J. Q., & MEHTA, R. L.
- Venue
- Journal of the American Society of Nephrology
- Published
- 1999-02
- Volume
- 10
- Issue
- 2
- Pages
- 392-403
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2149274940
- Cited by
- 310
- References
- 1
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Dry Weight in Hemodialysis: An Overview. https://app.cochat.ai/papers/10.1681/asn.v102392
- The paper
- JAEGER, J. Q., & MEHTA, R. L. (1999). Assessment of Dry Weight in Hemodialysis: An Overview. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.v102392
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.