Elastographic imaging of thermal lesions in the liver in vivo following radiofrequency ablation: preliminary results
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433 · cited 1×
“Differential displacements in small regions are detected using classical time-delay estimation techniques (Weinstein and Weiss 1984; Quazi 1981; Knapp and Carter 1976).”
MethodElastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116 · cited 1×
“…1987; Yamakoshi et al1990; Parker et al 1990; Ophir et al1991, 1997, 1999; O’Donnell et al 1991, 1994; Céspedes 1993; Plewes et al 1995; Fowlkes et al 1995; Muthupillai et al 1995; Varghese and Ophir 1998; Varghese et al 2000) is another technique that has been proposed to monitor thermal lesions.”
Small Hepatocellular Carcinoma: Treatment with Radio-frequency Ablation versus Ethanol Injection
Livraghi, T., Goldberg, S. N., Lazzaroni, S., Meloni, F., Solbiati, L., & Gazelle, G. S. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe40655 · Cited by 1,283 · cited 2×
“This results in heating and cauterization of the tumor mass and probe track (Goldberg et al 1998, 2000; DeSanctis et al 1998; Lee et al 1999a, 1999b; Curley et al 1999; Rhim and Dodd 1999; Livraghi et al 1999; Cha et al 2000).”
BackgroundCurley, S. A., Izzo, F., Delrio, P., Ellis, L. M., Granchi, J., Vallone, P., Fiore, F., Pignata, S., Daniele, B., & Cremona, F. (1999) · Annals of Surgery · doi:10.1097/00000658-199907000-00001 · Cited by 1,068 · cited 1×
“This results in heating and cauterization of the tumor mass and probe track (Goldberg et al 1998, 2000; DeSanctis et al 1998; Lee et al 1999a, 1999b; Curley et al 1999; Rhim and Dodd 1999; Livraghi et al 1999; Cha et al 2000).”
BackgroundGoldberg, S. N., Gazelle, G. S., & Mueller, P. R. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.2.1740323 · Cited by 1,062 · cited 3×
“The progressively increasing hyperechogenic region due to formation of gas bubbles in heated tissue does not represent the region of tissue coagulation (Malone et al 1994), and generally resolves within 1 h of ablation (Goldberg et al 2000).”
BackgroundHepatocellular Carcinoma: Radio-frequency Ablation of Medium and Large Lesions
Livraghi, T., Goldberg, S. N., Lazzaroni, S., Meloni, F., Ierace, T., Solbiati, L., & Gazelle, G. S. (2000) · Radiology · doi:10.1148/radiology.214.3.r00mr02761 · Cited by 1,013 · cited 1×
“This is an important area of research becausse areas around a blood vessel undergo only partial necrosis due to reduction in the thermal dose due to blood flow (Livraghi et al 2000).”
BackgroundElastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784 · cited 3×
“Imaging tissue elastic properties (Wilson and Robinson 1982; Krouskop et al 1987; Yamakoshi et al1990; Parker et al 1990; Ophir et al1991, 1997, 1999; O’Donnell et al 1991, 1994; Céspedes 1993; Plewes et al 1995; Fowlkes et al 1995; Muthupillai et al 1995; Varghese and Ophir 1998; Varghese et al…”
BackgroundSelf-citationPercutaneous RF interstitial thermal ablation in the treatment of hepatic cancer.
Rossi, S., Di Stasi, M., Buscarini, E., Quaretti, P., Garbagnati, F., Squassante, L., Paties, C. T., Silverman, D. E., & Buscarini, L. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.167.3.8751696 · Cited by 760 · cited 1×
“However, local recurrence rates as high as 34% to 55% have been reported for percutaneous RFA guided by conventional sonography (Solbiati et al 1997a, 1997b; Rossi et al 1996).”
BackgroundInternal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699 · cited 1×
“…tissue elastic properties (Wilson and Robinson 1982; Krouskop et al 1987; Yamakoshi et al1990; Parker et al 1990; Ophir et al1991, 1997, 1999; O’Donnell et al 1991, 1994; Céspedes 1993; Plewes et al 1995; Fowlkes et al 1995; Muthupillai et al 1995; Varghese and Ophir 1998; Varghese et al…”
Background
Cited by
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Motion Estimation in Ultrasound Images Using Time Domain Cross Correlation With Prior Estimates
Zahiri-Azar, R., & Salcudean, S. E. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.881780 · Cited by 214
“It has been shown to be useful in different clinical applications such as tumor detection in the breast [5]–[7] and prostate [8], monitoring of high intensity focused ultrasound lesions [9], imaging the myocardium [10], studying deep venous thrombosis [11]–[13], studying renal pathology [14], monitoring thermal change…”
BackgroundReal-Time Regularized Ultrasound Elastography
Rivaz, H., Boctor, E. M., Choti, M. A., & Hager, G. D. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2091966 · Cited by 177
Breast Lesions: Evaluation with US Strain Imaging–Clinical Experience of Multiple Observers
Regner, D. M., Hesley, G. K., Hangiandreou, N. J., Morton, M. J., Nordland, M. R., Meixner, D. D., Hall, T. J., Farrell, M. A., Mandrekar, J. N., Harmsen, W. S., et al. (2006) · Radiology · doi:10.1148/radiol.2381041336 · Cited by 175
Quasi-Static Ultrasound Elastography
Varghese, T. (2009) · Ultrasound Clinics · doi:10.1016/j.cult.2009.10.009 · Cited by 169
“An interesting offshoot is the utilization of the radiofrequency or microwave electrode itself to introduce the quasi-static deformation for both strain [88] and modulus [91] imaging.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Varghese, T., Zagzebski, J. A., & Lee, F. T.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2002-11
- Volume
- 28
- Issue
- 11-12
- Pages
- 1467-1473
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W1995365473
- Cited by
- 169
- References
- 29
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.