Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 175

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Breast Lesions: Evaluation with US Strain Imaging–Clinical Experience of Multiple Observers

Open access
Regner, Dawn M., Hesley, Gina K., Hangiandreou, Nicholas J., Morton, Marilyn J., Nordland, Michelle R., Meixner, Duane D., Hall, Timothy J., Farrell, Michael A., Mandrekar, Jayawant N., Harmsen, W. Scott, Charboneau, J. William · 2006 · Radiology

Abstract

PURPOSE: To prospectively determine the accuracy of using an ultrasonographic (US) strain imaging technique known as lesion size comparison to differentiate benign from malignant breast lesions. MATERIALS AND METHODS: Institutional Review Board approval and patient informed consent were obtained for this HIPPA-compliant study. US strain imaging was performed prospectively for 89 breast lesions in 88 patients. Lesions were imaged by using freehand compression and a real-time strain imaging algorithm. Five observers obtained manual measurements of lesion height, width, and area from B-mode and strain images. By using these size measurements, individual observer and group performances were assessed by using the area under the receiver operating characteristic curve (A(z)). The performance of a single size parameter versus that of a combination of size parameters was evaluated by using univariate and multivariate logistic regression. RESULTS: Group A(z) values showed that width ratio and area ratio yielded the best results for differentiating benign and malignant breast lesions, and they were not statistically different from one another (P = .499). For the group, the performance of area and width, which was superior to that of height and aspect ratio, was statistically significant for all cases (P < .011) except for those that compared area with aspect ratio (P = .118). By using a group threshold of 1.04 for width ratio and 1.13 for area ratio, the sensitivity and specificity of the technique were 96% and 21%, respectively, for width and 96% and 24%, respectively, for area. The best observer achieved a sensitivity of 96% and a specificity of 61% by using the area ratio. For all but one observer, combined size parameters did not improve observer performance (P > .258). Significant interobserver performance variability was observed (P < .001). CONCLUSION: Results suggest that US strain imaging has the potential to aid diagnosis of breast lesions. However, manually tracing lesion boundaries for size ratio differentiation in a busy clinical setting did not match the diagnostic performance levels previously reported. Focusing on measurements of lesion width, along with additional observer training or automated processes, may yield a suitable method for routine clinical application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2381041336

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 175

Metadata

Authors
Regner, D. M., Hesley, G. K., Hangiandreou, N. J., Morton, M. J., Nordland, M. R., Meixner, D. D., Hall, T. J., Farrell, M. A., Mandrekar, J. N., Harmsen, W. S., & Charboneau, J. W.
Venue
Radiology
Published
2006-02
Volume
238
Issue
2
Pages
425-437
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2167669297
Cited by
175
References
1
FWCI
8.31
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Breast Lesions: Evaluation with US Strain Imaging–Clinical Experience of Multiple Observers. https://app.cochat.ai/papers/10.1148/radiol.2381041336
The paper
Regner, D. M., Hesley, G. K., Hangiandreou, N. J., Morton, M. J., Nordland, M. R., Meixner, D. D., Hall, T. J., Farrell, M. A., Mandrekar, J. N., Harmsen, W. S., & Charboneau, J. W. (2006). Breast Lesions: Evaluation with US Strain Imaging–Clinical Experience of Multiple Observers. Radiology. https://doi.org/10.1148/radiol.2381041336

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.