The impact of corona electrode configuration on electrostatic precipitator performance
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the provided images illustrated how particles approaching the collection plate changed direction and got repelled back from the plate due to back e-field (see Fig. 4).”
From Influence of Back Electrostatic Field on the Collection Efficiency of an Electrostatic Lunar Dust Collector (2014) · cites this paper as Miller et al., 1998
Citations
Cites
Industrial Electrostatic Precipitation
White, H. J. (1963) · Cited by 766
Applied Electrostatic Precipitation
Parker, K. R. (1996) · Springer eBooks · doi:10.1007/978-94-009-1553-4 · Cited by 331
Basic and theoretical operation of ESPs
Riehle, C. (1997) · Springer eBooks · doi:10.1007/978-94-009-1553-4_3 · Cited by 35
Neuere Erkenntnisse und Anwendungen bei der elektrischen Abscheidung von Stäuben und Nebeltröpfchen
Mayer‐Schwinning, G., & Rennhack, R. (1980) · Chemie Ingenieur Technik · doi:10.1002/cite.330520503 · Cited by 14
Research works printed but not linked: 1
- Miller, 1996, Feinstaubabscheidung in betriebsoptimierten Elektrofiltern Berichte Umweltforschung Baden-Württemberg, FZKA-PEF, 140
Cited by
Modern electrostatic devices and methods for exhaust gas cleaning: A brief review
Jaworek, A., Krupa, A., & Czech, T. (2007) · Journal of Electrostatics · doi:10.1016/j.elstat.2006.07.012 · Cited by 392
“The optimal distance between discharge electrodes is nearly equal to half the gap spacing between plates [79].”
BackgroundTwo-stage electrostatic precipitators for the reduction of PM2.5 particle emission
Jaworek, A., Marchewicz, A., Sobczyk, A. T., Krupa, A., & Czech, T. (2018) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2018.03.003 · Cited by 231
Jędrusik, M., Świerczok, A., & Teisseyre, R. (2003) · Powder Technology · doi:10.1016/j.powtec.2003.08.021 · Cited by 86
Tu, G., Song, Q., & Yao, Q. (2017) · Powder Technology · doi:10.1016/j.powtec.2017.08.021 · Cited by 42
Evaluating Performance Indices of Electrostatic Precipitators
Badran, M., & Mansour, A. M. (2022) · Energies · doi:10.3390/en15186647 · Cited by 39
Al‐Hamouz, Z., El-Hamouz, A. M., & Abuzaid, N. S. (2010) · Advanced Powder Technology · doi:10.1016/j.apt.2010.10.005 · Cited by 33
“[27] investigated the impact of different electrode configurations on the WDEP efficiency.”
BackgroundTeng, C., Fan, X., & Li, J. (2020) · Journal of Electrostatics · doi:10.1016/j.elstat.2020.103426 · Cited by 29
Teng, C., & Li, J. (2021) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2021.09.035 · Cited by 27
Corona discharge characteristics of cylindrical electrodes in a two-stage electrostatic precipitator
Wen, T.-Y., & Su, J.-L. (2020) · Heliyon · doi:10.1016/j.heliyon.2020.e03334 · Cited by 27
“When the electric field around the corona electrode is stronger (or the corona current is higher), particles can get charged more efficiently, and thus the collection efficiency can be higher [6, 7, 8, 9].”
BackgroundAl‐Hamouz, Z. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.11.047 · Cited by 26
Teng, C., & Li, J. (2020) · Energy & Fuels · doi:10.1021/acs.energyfuels.0c00646 · Cited by 24
Tong, Y., Liu, L., Zhang, L., Bu, S., Chen, F., Shao, W., Feng, C., Xu, W., Qi, S., & Fu, L. (2019) · Separation and Purification Technology · doi:10.1016/j.seppur.2019.116299 · Cited by 23
Najafabadi, M. M., Tabrizi, H. B., Aramesh, A., & Ehteram, M. A. (2014) · Journal of Electrostatics · doi:10.1016/j.elstat.2014.06.005 · Cited by 21
“[6] presented results of an experimental investigation conducted with a laboratory scale electrostatic precipitator for optimizing the geometric parameters.”
MethodSoldati, A. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300957 · Cited by 21
“This result confirms on a theoretical basis the previous observations by Miller et al. (1998) based on experimental investigations.”
BackgroundResultInfluentialIntegrated Electrostatic Precipitator for Small‐Scaled Biomass Boilers
Berhardt, A., Lezsovits, F., & Groß, B. (2016) · Chemical Engineering & Technology · doi:10.1002/ceat.201600200 · Cited by 20
Chung, J. H., Kim, K. H., Sohn, D. K., & Ko, H. S. (2024) · Powder Technology · doi:10.1016/j.powtec.2024.119865 · Cited by 15
Sayed, A. M., Abouelatta, M. A., Badawi, M., Mahmoud, K., Lehtonen, M., & Darwish, M. M. F. (2021) · Electric Power Systems Research · doi:10.1016/j.epsr.2021.107634 · Cited by 14
Collection of Liquid Phase Particles by Microfabricated Electrostatic Precipitator
Chua, B., Wexler, A. S., Tien, N. C., Niemeier, D., & Holmén, B. A. (2013) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2013.2262597 · Cited by 14
Pieloth, D., Wiggers, H., & Walzel, P. E. (2014) · Chemical Engineering & Technology · doi:10.1002/ceat.201400012 · Cited by 13
Kim, K., Kim, S.-Y., & Jun, T. H. (2015) · Water Air & Soil Pollution · doi:10.1007/s11270-015-2614-0 · Cited by 11
“Low and uniform current densities at the collecting electrodes were achieved using small barb distances and small discharge electrode distance by Miller et al. (1998), suggesting that changing the electrode configuration can improve fine dust removal efficiency as well as reduce negative effects…”
BackgroundTong, Y., Zhang, L., Bu, S., Chen, F., Xu, W., Wu, R., Liu, L., & Xu, Y. (2019) · Powder Technology · doi:10.1016/j.powtec.2019.12.016 · Cited by 11
Analysis of a wire–duct electrostatic precipitator under dust loading conditions
Al‐Hamouz, Z., & El-Hamouz, A. M. (2010) · Energy Conversion and Management · doi:10.1016/j.enconman.2010.09.019 · Cited by 10
“[27] investigated the impact of different electrode configurations on the WDEP efficiency.”
BackgroundFalaguasta, M. C. R., Steffens, J. T., Valdés, E., & Coury, J. R. (2008) · Latin American Applied Research - An international journal · Cited by 9
Bächer, C., Lebedynskyy, V., Fischer, S., & Riebel, U. (2018) · Environmental Technology · doi:10.1080/09593330.2018.1555613 · Cited by 9
“[10] investigate barbed electrodes with canted or round barb tips, different barb lengths,”
BackgroundAfshar-Mohajer, N., Thakker, Y., Wu, C.-Y., & Sorloaica-Hickman, N. (2014) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2013.12.0353 · Cited by 8
“As a result, the classic equations derived for the conventional ESPs are not valid for the ELDC.”
InfluentialSayed, A. M., Ahmad, A. M., Ward, S. A., Shaalan, E. M., Darwish, M. M. F., Lehtonen, M., & Badawi, M. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110200 · Cited by 8
“While the effect of the wire duct ESP designs with diverse electrodes on the efficiency is tested by Miller et al. [30].”
Local occurrence of back corona at the dust layer of electrostatic precipitators
Hoferer, B., & Schwab, A. J. (2002) · IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) · doi:10.1109/ceidp.2000.885235 · Cited by 8
Self-citationBrocilo, D. (2003) · MacSphere (McMaster University) · doi:10.71548/8750 · Cited by 8
Optimization of Sawtooth Electrode for Improving Collection Efficiency of Electrostatic Precipitator
Hwang, S.-J., Hwang, S.-Y., Kim, H., & Yook, S. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3214804 · Cited by 6
“The operation of an ESP is divided into 5 steps: 1) occurrence of charge carriers due to corona discharge 2) particle charging due to diffusion charging and field charging 3) control of particulate behavior via gas flow and electrostatic force 4) particulate collection 5) particulate separation and removal [7], [8].”
BackgroundMethodEvaluation of the performance of a wire-plate electrostatic precipitator
Nóbrega, S. W., Arnosti, S., & Coury, J. R. (2001) · Brazilian Journal of Chemical Engineering · doi:10.1590/s0104-66322001000300010 · Cited by 6
Collector current density and dust collection in wire-plate electrostatic precipitators
Yuen, A. W. L. (2006) · UNSWorks (University of New South Wales, Sydney, Australia) · doi:10.26190/unsworks/17265 · Cited by 6
Method to increase cleaning degree of electrostatic air cleaner
Lysakov, A., Nikitenko, G. V., Konoplev, E., & Grinchenko, V. (2018) · Engineering for Rural Development · doi:10.22616/erdev2018.17.n187 · Cited by 5
“The main disadvantage of the dust filter is that it cleans only dust particles of medium dispersion, furthermore, the ultrafine dust concentration in the air due to the forced air movement may even increase [8; 9].”
BackgroundA portable electrostatic precipitator to reduce respiratory death in rural environments
Talukder, S., Park, S., & Rivas-Davila, J. (2017) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2017.8013316 · Cited by 5
“Moreover, smaller separations create a stronger corona that seems to enhance the collection of finer particles [7].”
BackgroundNon-static Collection Process of the electrostatic Precipitator
Wenge, H., & Hao-wang, X. (2009) · Springer eBooks · doi:10.1007/978-3-540-89251-9_15 · Cited by 4
Optimization of Sawtooth Electrode for Improving Collection Efficiency of Electrostatic Precipitator
Hwang, S.-J., Hwang, S.-Y., Kim, H., & Yook, S. (2021) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias48185.2021.9677040 · Cited by 3
Investigation of discharge phenomena in porous materials
Hoferer, B., & Schwab, A. J. (2003) · IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) · doi:10.1109/ceidp.2002.1048850 · Cited by 3
Self-citationKebria, H. Y., Zakeri, R., & Darbandi, M. (2026) · Powder Technology · doi:10.1016/j.powtec.2026.122128 · Cited by 2
Nokpho, P., Tanprasert, S., Chalermsinsuwan, B., & Piemjaiswang, R. (2026) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2026.124274 · Cited by 2
Calculation of electrostatic precipitator parameters for large poultry enterprise
Lysakov, A., Nikitenko, G. V., Grinchenko, V., & Avdeeva, V. (2020) · Engineering for Rural Development · doi:10.22616/erdev.2020.19.tf280 · Cited by 2
“the breakage of the inter-electrode air occurs [7-10].”
BackgroundUse of laminar ESP for the capture of titanium dioxide particles
Pawar, V. M. (2004) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 2
Lavisetty, P., Collins, D., Smith, C., Kleckner, K., Al-Habsha, A., Wang, J., Bates, A., Cook, D., & Gillman, I. G. (2026) · Aerosol Science and Technology · doi:10.1080/02786826.2026.2686134 · Cited by 1
Experimental Study on the Corona Discharge Characteristics of the Pin-plate Electrode Geometries
Cheong, S., Lee, J.-K., Chung, D., & Ahn, Y.-C. (2006) · Transactions of the Korean Society of Mechanical Engineers B · doi:10.3795/ksme-b.2006.30.2.095
AEROSOL PARTICLE COLLECTOR DESIGN STUDY
Lee, S., & Dimenna, R. R. (2007) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/917512
Design, Manufacturing, and Testing of a Pilot Wet Electrostatic Precipitator
Mannella, N. E. (2017) · OhioLink ETD Center (Ohio Library and Information Network)
Non-ohmic Properties of Particle Layers in Electrostatic Precipitators
Pieloth, D., Wiggers, H., & Walzel, P. E. (2019) · Springer eBooks · doi:10.1007/978-3-030-15899-6_19
HASKAR, H., MILOUA, F., & BOUZID-DAHO, A. (2026) · Electrotehnica, Electronica, Automatica · doi:10.46904/eea.26.74.1.1108008
The numerical modelling of a flue gas precipitator
Eeden, V., & Christian, G. (2003) · Boloka Institutional Repository (North-west University)
Magnetic and electrode synergy for enhanced fine particle capture in electrostatic precipitator
Mu, R., Zheng, Y., Wang, S., & Zhang, J. (2026) · Journal of Electrostatics · doi:10.1016/j.elstat.2026.104367
Metadata
- Authors
- Miller, J., Hoferer, B., & Schwab, A. J.
- Affiliations
- Karlsruhe Institute of Technology (DE)
- ORCID
- Schwab, A.J.
- Venue
- Journal of Electrostatics
- Publisher
- Elsevier BV
- Published
- 1998-07
- Volume
- 44
- Issue
- 1-2
- Pages
- 67-75
- ISSN
- 0304-3886 (ISSN-L)
- OpenAlex
- W1981350962
- Cited by
- 42
- References
- 4
- Citations by year
- 2026: 5 · 2024: 2 · 2022: 2 · 2021: 3 · 2020: 4 · 2019: 3 · 2018: 3 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 4 · 2013: 1
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Electrostatics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Physical Sciences › Engineering › Computational Mechanics › Cyclone Separators and Fluid Dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- electrostatic precipitator, particle collection efficiency, current distribution uniformity, electrode geometry optimization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.