Cited by 23Peripheral Nerve DisordersMagnetic Field Sensors TechniquesNeuroscience and Neural Engineering

Peripheral nerve conduction recorded by a micro gradiometer system (micro-SQUID) in humans

Hoshiyama, Minoru, Kakigi, Ryusuke, Nagata, Osamu·1999·Neuroscience Letters

Abstract

We developed a new multi (twelve) -channel gradiometer system with the smallest and highest quality superconducting quantum interference device (micro-SQUID). A very small distance (3.80 mm) between the sensor coils and the skin provides quite high spatial resolution. The actual whole image of the sensory nerve action fields (NAF) of the human median nerve at the wrist were successfully recorded following digital nerve stimulation by using the micro-SQUID. The NAF showed the biphasic waveform at each of the 12 channels, and the isomagnetic field map clearly showed the moving quadrupole pattern. The quadrupole comprised a dipole for depolarization followed by another dipole with the opposite direction for repolarization. The polarized length of the nerve obtained by reconstructing the magnetic field maps was approximately 17 cm, and the magnetic field complex moved along the nerve from the distal to the proximal part of the wrist at 58.7 m/s.

Integrity signals

Registry

Crossref · 10.1016/s0304-3940(99)00589-3

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Extremely weak magnetic fields generated by the ion flows of evoked compound nerve action potentials can be detected using SQUID sensors with high spatial and temporal resolution.

    “Extremely weak magnetic fields generated by the ion flows of evoked compound nerve action potentials can be detected using superconducting quantum interference device (SQUID) sensors with high spatial and temporal resolution”

Cited by

Sorted by citations

Authors
Hoshiyama, M., Kakigi, R., & Nagata, O.
Affiliations
National Institute for Physiological Sciences (JP)
Corresponding author
Hoshiyama, Minoru
Venue
Neuroscience Letters
Publisher
Elsevier BV
Published
1999-09
Volume
272
Issue
3
Pages
199-202
ISSN
0304-3940 (ISSN-L)
OpenAlex
W2060878950
Cited by
23
References
0
Citations by year
2025: 1 · 2023: 1 · 2022: 2 · 2019: 3 · 2017: 1 · 2013: 1
FWCI
1.60
Type
journal article
Language
en
Open access
closed
Locations
  • Neuroscience Letters (publishedVersion)
  • PubMed (publishedVersion)
Funders
Ministry of Education, Culture, Sports, Science and Technology (C-10670614)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Peripheral Nerve Disorders
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
peripheral nerve conduction, micro-SQUID, superconducting quantum interference devices, median nerve, magnetic field mapping
MeSH terms
Adult, Electric Stimulation, Electromagnetic Fields, Electrophysiology, Female, Fingers, Humans, Male, Median Nerve, Neural Conduction, Peripheral Nerves, Wrist

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review