CoChat

Low intensity vagal nerve stimulation lowers human thermal pain thresholds

Ness, T. J., Fillingim, R. B., Randich, A., Backensto, E. M., Faught, E. · 2000 · Pain
Cited by 90

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The effect of vagal nerve stimulation (VNS) on thermal pain sensation was studied in eight subjects who had vagal nerve stimulators surgically implanted for purposes of seizure control. Prior to their involvement in the study, all subjects had the intensity of their VNS (30 Hz, 0.5 ms, 1.0-2.75 mA) adjusted upwards until achieving their desired clinical effect of reduced seizures. Thermal pain thresholds were determined using a Medoc TSA-2001 with a thermode applied to the skin of the forearm. During VNS at settings 100% of those used clinically to control their seizures, subjects showed a statistically significant decrease in their thermal pain threshold of 1.1+/-0.4 degrees C. Acute effects of graded VNS on thermal pain thresholds were determined in seven of the subjects after cessation of chronic VNS. Two thermal threshold measurements were obtained while the subject received sham stimulation (0 mA intensity), during tactile control stimulation and during 30 s of VNS at intensities approximately 33, 66 and 100% of the settings utilized to control their seizures. Tactile control stimulation was provided by electrical stimulation of the skin of the ankle with the intensity adjusted by the patient to match the intensity of any sensations felt in the neck during VNS. Subjects were not aware of the settings employed. Their stimulator was adjusted with each trial and an ascending/descending ordering of intensity was utilized with an inter-trial interval of 2 min. Thermal pain thresholds were significantly decreased in relation to tactile control stimulation at all intensities of VNS tested with the greatest effect occurring at the 66% level. Subjects were also monitored non-invasively and hemodynamic responses to VNS were determined. No significant alterations in hemodynamic variables were observed. The findings of this human study are consistent with experiments in non-human animals which demonstrate a pro-nociceptive effect of low intensity VNS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0304-3959(00)00237-2

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 90

Metadata

Authors
Ness, T. J., Fillingim, R. B., Randich, A., Backensto, E. M., & Faught, E.
Venue
Pain
Published
2000-05
Volume
86
Issue
1
Pages
81-85
ISSN
0304-3959 (ISSN-L)
OpenAlex
W2132564337
Cited by
90
References
2
FWCI
2.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low intensity vagal nerve stimulation lowers human thermal pain thresholds. https://app.cochat.ai/papers/10.1016/s0304-3959(00)00237-2
The paper
Ness, T. J., Fillingim, R. B., Randich, A., Backensto, E. M., & Faught, E. (2000). Low intensity vagal nerve stimulation lowers human thermal pain thresholds. Pain. https://doi.org/10.1016/s0304-3959(00)00237-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.