Determination of ammonia in seawater by the indophenol-blue method: Evaluation of the ICES NUTS I/C 5 questionnaire
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Abstract Replies to the questionnaire on the determination of ammonia, sent to participants in the Fifth ICES Intercomparison Exercise for nutrients in seawater, are evaluated. The conclusions provide some useful recommendations for analysts. Berthelot's reaction (formation of indophenol-blue) is the basis of the colorimetry used by the great majority of participants, and their individual methods are examined in detail. Application of the indophenol-blue method to seawater poses some specific problems, for example, precipitation, and variation of the pH of the matrix as a function of salinity. Basic principles are discussed and participants' procedures are compared with those most commonly used in the literature. Large disparities in reaction and operating conditions are evident between these many versions of what is nominally the same method. Various points of the reaction mechanism are examined in order to determine optimal ranges for reagent concentrations. Procedures for calibration, measuring the blank, and defining the concentration-zero are also evaluated, as the intercomparison results indicate that systematic (particularly relative) errors are widespread. The use of low-nutrient seawater as a calibration matrix is strongly recommended if errors such as those incurred by the use of demineralised water or artificial seawater are to be avoided. Sources of contamination are discussed, the majority of participants being aware that ambient laboratory air can be a major problem. In general, users of automated methods produce better results than users of manual methods, but this may simply reflect a tendency for the former to be the more experienced analysts. Although it was not possible consistently to relate performance in the intercomparison with methodology, it would appear that many procedures deviate from optimal operating conditions, while some are unnecessarily complicated and might benefit from simplification. Analysts are invited to re-examine their ammonia methods, with particular attention to suitability of reagents and reaction conditions, use of adequate blank and calibration procedures and matrices, correction for refraction effects and identification of local contamination sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standard methods: For the examination of water and waste water
(1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90598-4 · Cited by 72,091
Standard Methods for the Examination of Water and Wastewater
Jenkins, S. H. (1982) · Water Research · doi:10.1016/0043-1354(82)90249-4 · Cited by 30,002
A practical hand-book of seawater analysis
Strickland, J., & PARSONS, T. R. (1968) · Helmholtz-Zentrum für Polar-und Meeresforschung (Alfred-Wegener-Institut) · Cited by 10,489
(1999) · Wiley eBooks · doi:10.1002/9783527613984 · Cited by 7,730
Modified Reagents for Determination of Urea and Ammonia
Chaney, A. L., & Marbach, E. P. (1962) · Clinical Chemistry · doi:10.1093/clinchem/8.2.130 · Cited by 3,938
Hamilton, E. I. (1984) · Marine Pollution Bulletin · doi:10.1016/0025-326x(84)90495-8 · Cited by 3,673
SOLÓRZANO, L. (1969) · Limnology and Oceanography · doi:10.4319/lo.1969.14.5.0799 · Cited by 3,501
Ammonia determination based on indophenol formation with sodium salicylate
Verdouw, H., Van Echteld, C. J. A., & Dekkers, E. M. J. (1978) · Water Research · doi:10.1016/0043-1354(78)90107-0 · Cited by 1,265
Wangersky, P. (1985) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(85)80011-x · Cited by 1,045
Patton, C. J., & Crouch, S. R. (1977) · Analytical Chemistry · doi:10.1021/ac50011a034 · Cited by 842
Cited by
A simple and precise method for measuring ammonium in marine and freshwater ecosystems
Holmes, R. M., Aminot, A., Kérouel, R., Hooker, B., & Peterson, B. J. (1999) · Canadian Journal of Fisheries and Aquatic Sciences · doi:10.1139/cjfas-56-10-1801 · Cited by 1,376
Self-citationSáez-Plaza, P., Navas, M. J., Wybraniec, S., Michałowski, T., & Asuero, A. G. (2013) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2012.751787 · Cited by 523
Santoro, A. E., Casciotti, K. L., & Francis, C. A. (2010) · Environmental Microbiology · doi:10.1111/j.1462-2920.2010.02205.x · Cited by 398
Holmes, R. M., McClelland, J. W., Sigman, D. M., Fry, B., & Peterson, B. J. (1998) · Marine Chemistry · doi:10.1016/s0304-4203(97)00099-6 · Cited by 366
Fluorometric determination of ammonia in sea and estuarine waters by direct segmented flow analysis
Kérouel, R., & Aminot, A. (1997) · Marine Chemistry · doi:10.1016/s0304-4203(97)00040-6 · Cited by 339
Self-citationTaylor, B. W., Keep, C. F., Hall, R. O., Koch, B. J., Tronstad, L. M., Flecker, A. S., & Ulseth, A. J. (2007) · Journal of the North American Benthological Society · doi:10.1899/0887-3593(2007)26[167:itfamm]2.0.co;2 · Cited by 223
“For example, NH4 þ can be relatively unstable during sample preservation, and numerous sources of contamination during sample collection, preservation, and analysis hinder measuring low concentrations of NH4 þ (Eaton and Grant 1979, Aminot et al. 1997).”
BackgroundEnergy-efficient electrochemical ammonia production from dilute nitrate solution
Kim, K.-H., Lee, H., Huang, X., Choi, J. H., Chen, C., Kang, J. K., & O’Hare, D. (2023) · Energy & Environmental Science · doi:10.1039/d2ee03461a · Cited by 211
Metabolomics-driven quantitative analysis of ammonia assimilation in E. coli
Yuan, J., Doucette, C. D., Fowler, W. U., Feng, X., Piazza, M., Rabitz, H. A., Wingreen, N. S., & Rabinowitz, J. D. (2009) · Molecular Systems Biology · doi:10.1038/msb.2009.60 · Cited by 178
“The wash was then assayed for ammonium using the indophenol blue method (Aminot et al, 1997), and the concentration of ammonium in the surface of the plate was then calculated.”
Determination of ammonia nitrogen in natural waters: Recent advances and applications
Lin, K., Zhu, Y., Zhang, Y., & Lin, H. (2019) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2019.e00073 · Cited by 177
Influence of stream size on ammonium and suspended particulate nitrogen processing
Wollheim, W. M., Peterson, B. J., Deegan, L. A., Hobbie, J. E., Hooker, B., Bowden, W. B., Edwardson, K. J., Arscott, D. B., Hershey, A. E., & Finlay, J. (2001) · Limnology and Oceanography · doi:10.4319/lo.2001.46.1.0001 · Cited by 166
“Estimates of low-level NH4 concentrations using the colorimetric technique are difficult (Aminot et al. 1997; Holmes et al. 1999), and we were often near the limit of detection.”
BackgroundMethod
Metadata
- Authors
- Aminot, A., Kirkwood, D. S., & Kérouel, R.
- Venue
- Marine Chemistry
- Publisher
- Elsevier BV
- Published
- 1997-02
- Volume
- 56
- Issue
- 1-2
- Pages
- 59-75
- ISSN
- 0304-4203 (ISSN-L)
- OpenAlex
- W2073433356
- Cited by
- 160
- References
- 15
- FWCI
- 10.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.