Building thermal model reduction using nonlinear constrained optimization
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principal component analysis in linear systems: Controllability, observability, and model reduction
Moore, B. (1981) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1981.1102568 · Cited by 5,282
Levary, R. R. (1982) · European Journal of Operational Research · doi:10.1016/0377-2217(82)90093-5 · Cited by 4,158
A fast algorithm for nonlinearly constrained optimization calculations
Powell, M. J. D. (1978) · Lecture Notes in Mathematics · doi:10.1007/bfb0067703 · Cited by 1,661
NLPQL: A fortran subroutine solving constrained nonlinear programming problems
Schittkowski, K. (1986) · Annals of Operations Research · doi:10.1007/bf02022087 · Cited by 1,484
A globally convergent method for nonlinear programming
Han, S. P. (1977) · Journal of Optimization Theory and Applications · doi:10.1007/bf00932858 · Cited by 1,097
Energy Simulation in Building Design
Clarke, J. (2007) · Routledge eBooks · doi:10.4324/9780080505640 · Cited by 964
Mathematical Programming The State of the Art
Bachem, A., Grötschel, M., & Korte, B. H. (1983) · Springer eBooks · doi:10.1007/978-3-642-68874-4 · Cited by 728
Zimmermann, H. (1979) · European Journal of Operational Research · doi:10.1016/0377-2217(79)90240-6 · Cited by 698
THE CONVERGENCE OF VARIABLE METRIC METHODS FOR NONLINEARLY CONSTRAINED OPTIMIZATION CALCULATIONS
Powell, M. J. D. (1978) · Nonlinear Programming 3 · doi:10.1016/b978-0-12-468660-1.50007-4 · Cited by 541
Variable Metric Methods for Constrained Optimization
Powell, M. J. D. (1983) · Mathematical Programming The State of the Art · doi:10.1007/978-3-642-68874-4_12 · Cited by 373
A comparative performance evaluation of 27 nonlinear programming codes
Hock, W., & Schittkowski, K. (1983) · Computing · doi:10.1007/bf02242139 · Cited by 172
Third-order lumped-parameter simulation method
Tindale, A. (1993) · Building Services Engineering Research and Technology · doi:10.1177/014362449301400302 · Cited by 69
Cited by
State of the art in building modelling and energy performances prediction: A review
Foucquier, A., Robert, S., Suard, F., Stéphan, L., & Jay, A. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.004 · Cited by 832
A review on modeling and simulation of building energy systems
Harish, V. S. K. V., & Kumar, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.040 · Cited by 691
Grey-box modeling and application for building energy simulations - A critical review
Li, Y., O'Neill, Z., Zhang, L., Chen, J., Im, P., & DeGraw, J. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111174 · Cited by 359
Hazyuk, I., Ghiaus, C., & Penhouet, D. (2012) · Building and Environment · doi:10.1016/j.buildenv.2011.11.009 · Cited by 242
“Building envelope is usually represented by 2R-C [11, 24, 25] or 3R-2C [12, 30-32] networks.”
BackgroundOccupancy-based zone-climate control for energy-efficient buildings: Complexity vs. performance
Goyal, S., Ingley, H. A., & Barooah, P. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.01.039 · Cited by 225
“the resistances and the capacitances of the walls and windows depend on their construction, and can be determined from properties listed in [22] and methods described in [23].”
Method
Metadata
- Authors
- Gouda, M. M., Danaher, S., & Underwood, C. P.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2002-12
- Volume
- 37
- Issue
- 12
- Pages
- 1255-1265
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2049425685
- Cited by
- 250
- References
- 12
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.