The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Reliability of two-point discrimination measurements
Open accessAbstract
Both moving and static two-point discrimination are valid measurements of functional sensibility in the hand. The present study investigated the interobserver variability of these measurements when two observers used the same testing instrument and the same definition of the testing procedure's end point. In testing 30 nerve-injured patients, interobserver variability was found to vary within 1 mm, or less, for moving two-point discrimination in 93.3% of the measurements and for static two-point discrimination in 86.8% of the measurements. In only two of the 30 measurements of moving two-point discrimination and in four of the measurements for static two-point discrimination were interobserver differences equal to 2 mm. Measurements for both moving and static two-point discrimination were analyzed statistically by linear regression and correlation co-efficient techniques. The measurements for two-point discrimination obtained with the protocol employed in this study were found to have an interobserver reliability at the p less than 0.00001 level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reliability and validity of grip and pinch strength evaluations
Mathiowetz, V., Weber, K., Volland, G., & Kashman, N. (1984) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(84)80146-x · Cited by 1,857
Parry, C. B. W. (1981) · Injury · doi:10.1016/0020-1383(81)90228-x · Cited by 468
Two-point discrimination tester
Mackinnon, S. E., & Dellon, A. L. (1985) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(85)80173-8 · Cited by 186
Self-citationEvaluation of functional sensation in the hand
Lee Dellon, A., & Kallman, C. H. (1983) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(83)80083-5 · Cited by 173
The force/time relationship of clinically used sensory testing instruments
Bell-Krotoski, J. A., & Buford, W. L. (1997) · Journal of Hand Therapy · doi:10.1016/s0894-1130(97)80045-2 · Cited by 145
Cited by
Postural stability in the elderly: a comparison between fallers and non-fallers
Melzer, I. (2004) · Age and Ageing · doi:10.1093/ageing/afh218 · Cited by 706
Ruijs, A. C. J., Jaquet, J.-B., Kalmijn, S., Giele, H., & Hovius, S. E. R. (2005) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000172896.86594.07 · Cited by 452
Bell-Krotoski, J., Weinstein, S., & Weinstein, C. (1993) · Journal of Hand Therapy · doi:10.1016/s0894-1130(12)80292-4 · Cited by 296
Palumbo, A., Aluru, V., Battaglia, J., Geller, D., Turry, A., Ross, M., Cristian, A., Balagula, C., Ogedegbe, G., Khatri, L., et al. (2022) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001938 · Cited by 46
Metadata
- Authors
- Dellon, A. L., Mackinnon, S. E., & Crosby, P. M.
- Venue
- The Journal of Hand Surgery
- Publisher
- Elsevier BV
- Published
- 1987-09
- Volume
- 12
- Issue
- 5
- Pages
- 693-696
- ISSN
- 0363-5023 (ISSN-L)
- OpenAlex
- W1972631024
- Cited by
- 303
- References
- 5
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of two-point discrimination measurements. https://app.cochat.ai/papers/10.1016/s0363-5023(87)80049-7
- The paper
- Dellon, A. L., Mackinnon, S. E., & Crosby, P. M. (1987). Reliability of two-point discrimination measurements. The Journal of Hand Surgery. https://doi.org/10.1016/s0363-5023(87)80049-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.