Direct determination of anabolic steroid conjugates in human urine by combined high-performance liquid chromatography and tandem mass spectrometry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A novel screening procedure for the sulfate and glucuronide conjugates of testosterone (T) and epitestosterone (E) in human urine was developed based on liquid-solid extraction and microbore high-performance liquid chromatography combined on-line with ion-spray tandem mass spectrometry. Confirmation of the sulfate and glucuronide conjugates of testosterone and epitestosterone isolated from normal human urine was achieved by selected reaction monitoring of characteristic product ions of the parent compounds. Endogenous levels of the steroid conjugates are detected in normal male urine and an increase is observed when the sample is fortified with authentic analytical standards of the conjugates. Calibration curves of all steroid conjugates in urine are linear over a range of twenty. Deuterated internal standards of testosterone glucuronide and epitestosterone sulfate were used for quantitation of the endogenous conjugates. T/E ratios were determined based on the glucuronide fractions of six replicates from a normal male and were shown to be statistically reproducible and below the accepted T/E threshold of 6:1. Sulfate conjugates were shown to be present at significantly lower levels in the urine. The method has potential as an alternative for monitoring anabolic steroid conjugates in human urine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Profiling steroid hormones and urinary steroids
Shackleton, C. H. L. (1986) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)80683-0 · Cited by 291
Cited by
LC/MS applications in drug development
Lee, M. S., & Kerns, E. H. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:3/4<187::aid-mas2>3.0.co;2-k · Cited by 339
Leinonen, A., Kuuranne, T., & Kostiainen, R. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.328 · Cited by 193
Mass spectrometry in sports drug testing: Structure characterization and analytical assays
Thevis, M., & Schänzer, W. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20107 · Cited by 191
Gas chromatography and high-performance liquid chromatography of natural steroids
Shimada, K., Mitamura, K., & Higashi, T. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)00943-8 · Cited by 185
Badoud, F., Grata, E., Boccard, J., Guillarme, D., Veuthey, J.-L., Rudaz, S., & Saugy, M. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4779-8 · Cited by 97
Metadata
- Authors
- Bean, K. A., & Henion, J. D.
- Venue
- Journal of Chromatography B: Biomedical Sciences and Applications
- Publisher
- Elsevier BV
- Published
- 1997-03
- Volume
- 690
- Issue
- 1-2
- Pages
- 65-75
- ISSN
- 0378-4347 (ISSN-L)
- OpenAlex
- W2042592938
- Cited by
- 89
- References
- 1
- FWCI
- 21.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.