A review of impedance measurements for determination of the state-of-charge or state-of-health of secondary batteries
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Example algorithms that utilize information from the EIS of a battery include, but are not limited to, DC impedance (or the zero-phase impedance point), the EIS minimum impedance magnitude point, and the 1 kHz (or another frequency) impedance point, among others.”
From An Electrochemical Impedance Spectrum-Based State of Health Differential Indicator with Reduced Sensitivity to Measurement Errors for Lithium–Ion Batteries (2024) · cites this paper as [26]
In the citing paper
“Utilizing the EIS information for SOH estimation is drawing increasing attention due to its speed, in addition to its ability to reflect the internal changes to the battery.”
From An Electrochemical Impedance Spectrum-Based State of Health Differential Indicator with Reduced Sensitivity to Measurement Errors for Lithium–Ion Batteries (2024) · cites this paper as [26]
In the citing paper
“This directly relates to possible degradation inside the battery and is able to track the status of the battery22.”
From Identifying degradation patterns of lithium ion batteries from impedance spectroscopy using machine learning (2020) · cites this paper as [22]
In the citing paper
“the fit is often non-unique and it is questionable whether a purely electrical model can capture the physical, chemical and materials properties and processes of a battery”
From Identifying degradation patterns of lithium ion batteries from impedance spectroscopy using machine learning (2020) · cites this paper as [22]
Citations
Cites
Barak, M. (1974) · Electronics and Power · doi:10.1049/ep.1974.0468 · Cited by 1,230
Collins, D., & Plambeck, J. A. (1971) · Cited by 835
(1981) · Springer eBooks · doi:10.1007/978-94-009-8423-3 · Cited by 617
Lead/acid batteries for photovoltaic applications. Test results and modeling
Copetti, J. B., & Chenlo, F. (1994) · Journal of Power Sources · doi:10.1016/0378-7753(94)80054-5 · Cited by 96
Impedance of a porous electrode with an axial gradient of concentration
Keddam, M., Rakotomavo, C., & Takenouti, H. (1984) · Journal of Applied Electrochemistry · doi:10.1007/bf00610808 · Cited by 94
Impedance measurement on Pb/H2SO4 batteries
Keddam, M., Stoynov, Z. B., & Takenouti, H. (1977) · Journal of Applied Electrochemistry · doi:10.1007/bf00616766 · Cited by 83
Impedance study of non-stationary systems: four-dimensional analysis
Stoynov, Z. B., & Savova-Stoynov, B. (1985) · Journal of Electroanalytical Chemistry · doi:10.1016/0368-1874(85)85486-1 · Cited by 77
The impedance of electrical storage cells
Hampson, N. A., Karunathilaka, S. A. G. R., & Leek, R. (1980) · Journal of Applied Electrochemistry · doi:10.1007/bf00937331 · Cited by 72
Impedance parameters and the state-of charge. I. Nickel-cadmium battery
Sathyanarayana, S., Venugopalan, S., & Gopikanth, M. L. (1979) · Journal of Applied Electrochemistry · doi:10.1007/bf00620594 · Cited by 64
Impedance parameters and the state-of-charge. II. Lead-acid battery
Gopikanth, M. L., & Sathyanarayana, S. (1979) · Journal of Applied Electrochemistry · doi:10.1007/bf01112492 · Cited by 50
Research works printed but not linked: 7
- Gabrielli, 1983, Identification of electrochemical processes by frequency response analysis. Solartron, Technical Report No 4183, 120
- Keddam, 1984, 14, 277
- Gabrielli, 1981, Vol. 81–82, 20
- Alzieu, 1990, A. Vicaud Rev. Gén. Électrique, 3, 50
- Gabriel, 1993, Vol. 1, 38
- Hlavac, 1993, Vol. 1, 44
- Feder, 1994, Batteries Int., 18, 60
Cited by
Items 301–400 of 615
Continuous Battery Health Diagnosis by On-Line Internal Resistance Measuring
Llerandi, J. D. L. P., Sancho, C., & Ibáñez, J. C. (2019) · Energies · doi:10.3390/en12142836 · Cited by 14
“The influence of the frequency of measurement on the value obtained for the internal resistance has been widely studied [19,20,36,39].”
BackgroundInfluentialAC impedance technique for dynamic and static state of charge analysis for Li-ion battery
Luo, Y., Gong, C. A., Chang, L.-X., & Liu, Y. (2013) · IEEE International Symposium on Consumer Electronics (ISCE) · doi:10.1109/isce.2013.6570268 · Cited by 14
“The AC impedance analysis has been thoroughly researched in recent years; it is proposed to estimate SOC and state of health (SOH) for Li-ion battery [4].”
BackgroundSensitivity analysis of lithium-ion battery model to battery parameters
Rahimi-Eichi, H., Balagopal, B., Chow, M., & Yeo, T. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6700257 · Cited by 14
“Several modeling techniques have been proposed to represent the battery more accurately and to estimate the SOC [7-9] and SOH [4], [7].”
MethodAdaptive fuzzy coup de fouet based VRLA battery capacity estimation
Pascoe, P. E., & Al‐Anbuky, A. (2002) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2001.972875 · Cited by 14
Abu Qahouq, J. (2024) · Batteries · doi:10.3390/batteries10100368 · Cited by 13
“As discussed in the next Unlike the Nyquist plot, the presented Phase–Magnitude relationship/plot consists of a plot that shows the magnitude and phase information instead of real and complex components/parts. plot of Figure EIS data are for a Tenergy ICR 18650-2600 lithium–ion battery cell [30] that was using the Gam…”
InfluentialMiddlemiss, L. A., Rennie, A. J. R., Sayers, R., & West, A. R. (2024) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ad1c0f · Cited by 13
Xie, Q., Kim, Y., Wang, Y., Kim, J., Chang, N., & Pedram, M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295601 · Cited by 13
“Considerable research efforts have been invested to develop an accurate and low computational-cost online SoC and SoH estimation methods [28], [29], [30], [31].”
ANN modeling of cold cranking test for sealed lead-acid batteries
Karami, H., Karimi, M. A., & Mahdipour, M. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.11.024 · Cited by 15
A transient-based approach to estimation of the electrical parameters of a lead-acid battery model
Mandal, L. P., & Cox, R. W. (2010) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2010.5617720 · Cited by 13
“Lock-in amplifiers or correlation techniques are then used to determine the real and imaginary parts of the impedance over a range of frequencies [5], [6].”
BackgroundMethodResultInfluentialRiabokin, O., Бойчук, А. В., & Pershina, K. (2018) · Surface Engineering and Applied Electrochemistry · doi:10.3103/s1068375518060108 · Cited by 13
A sensor of sulfuric acid specific gravity for lead-acid batteries
Guo, Y. (2004) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(04)00424-1 · Cited by 13
Effects of floating charge ageing on electrochemical impedance spectroscopy of lead-acid batteries
Pang, Z., Yang, K., Song, Z., Chen, G., Niu, P., Wang, S., & Meng, J. (2024) · Journal of Energy Storage · doi:10.1016/j.est.2024.111322 · Cited by 12
Nondestructive forensic pathology of Lead-Acid batteries
Shi, Y., Ferone, C., Rao, C., & Rahn, C. D. (2012) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2012.6315172 · Cited by 12
“This motivates the use of current and voltage data to assess battery health using full charge/discharge, pulse charge/discharge, and Electrochemical Impedance Spectroscopy (EIS).”
MethodTan, S., Huang, S.-W., Hsieh, Y., & Lin, S.-S. (2021) · Energies · doi:10.3390/en14154423 · Cited by 12
“The discharge characteristic curve of the lithium-ion battery has been modeled by several methods [3–5] including the discharge test [6], ampere hour counting [4], open circuit voltage [4], linear modeling [7], physical properties of the electrolyte [4], internal resistance [4], impedance spectroscopy [8], Kalman filt…”
MethodEstimating the State of Health of Lead-Acid Battery Using Feed-Forward Neural Network
Selvabharathi, D., & Muruganantham, N. (2021) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126622500815 · Cited by 14
An Efficient State of Charge Prediction Model for Solar Harvesting WSN Platforms
Castagnetti, A., Pégatoquet, A., Belleudy, C., & Auguin, M. (2012) · HAL · Cited by 12
Simultaneous real-time measurements of potential and high-frequency resistance of a lab cell
Huet, F., Nogueira, R. P., Torcheux, L., & Lailler, P. (2003) · Journal of Power Sources · doi:10.1016/s0378-7753(02)00557-8 · Cited by 12
Self-citationKowal, J., Budde-Meiwes, H., & Sauer, D. U. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.12.015 · Cited by 12
Lee, J., Kim, Y., & Cha, H. (2011) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2011.6063957 · Cited by 17
“There are basically two parameter extraction methods reported in literature: on-line [1] and off-line parameter extraction methods [7], [8].”
MethodModeling the condition of lithium ion batteries using the extreme learning machine
Densmore, A., & Hanif, M. (2016) · IEEE PES PowerAfrica · doi:10.1109/powerafrica.2016.7556597 · Cited by 14
An Ultrafast Maximum Power Point Tracking Technique for Optimal Battery Charging
Hussein, A. A.-H., Fardoun, A. A., & Stephen, S. S. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2017.2679161 · Cited by 12
Extraction of Intrinsic Parameters of Lead–Acid Batteries Using Energy Recycling Technique
Cheng, C. S., Lau, R. W.-H., Rathi, N., & Chung, H. S.-H. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2865670 · Cited by 12
“Many condition monitoring techniques, such as open-circuit voltage test [3], [4], internal resistance test [5], [6], impedance measurement [7]–[11], electrochemical impedance spectroscopy (EIS) [12]–[16], compensated synchronous detection [17]–[21], and pulse power tests [22]–[27], have been proposed.”
BackgroundDesign of measuring and evaluation unit for multi-cell traction battery system of industrial AGV
Frivaldský, M., Šedo, J., Pipiska, M., & Danko, M. (2020) · Electrical Engineering · doi:10.1007/s00202-020-00982-z · Cited by 12
Lithium-ion battery modeling using CC–CV and impedance spectroscopy characterizations
Stübler, T., Lahyani, A., & Zayoud, A. A. (2020) · SN Applied Sciences · doi:10.1007/s42452-020-2675-6 · Cited by 12
An Energy-Friendly Scheduler for Edge Computing Systems
Llorens-Carrodeguas, A., Sagkriotis, S. G., Cervelló-Pastor, C., & Pezaros, D. P. (2021) · Sensors · doi:10.3390/s21217151 · Cited by 15
“, state of health and model) by taking into account the used estimation model [27].”
MethodA Review on Battery Management System for Electric Vehicles
Nikhil, K. N. (2022) · International Journal for Research in Applied Science and Engineering Technology · doi:10.22214/ijraset.2022.45878 · Cited by 12
Online Identification of VLRA Battery Model Parameters Using Electrochemical Impedance Spectroscopy
Olarte, J., de Ilarduya, J. M., Zulueta, E., Ferret, R., Garcia-Ortega, J., & López-Guede, J. M. (2022) · Batteries · doi:10.3390/batteries8110238 · Cited by 12
Lead-acid battery modelling in perspective of ageing: a review
Mohsin, M. R., Picot, A., & Maussion, P. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864849 · Cited by 12
“A very good review for detecting SoH of a battery through impedance spectroscopy is presented in [17].”
BackgroundMultiple model impedance spectroscopy techniques for testing electrochemical systems
Tinnemeyer, J. A. (2004) · Journal of Power Sources · doi:10.1016/j.jpowsour.2004.03.022 · Cited by 12
Modeling and Simulation of Lithium-Ion Batteries from Systems Engineering Perspective
Ramadesigan, V., Northrop, P. W. C., De, S., Santhanagopalan, S., Braatz, R. D., & Subramanian, V. R. (2010) · ECS Meeting Abstracts · doi:10.1149/2.018203jes · Cited by 12
Online Battery Monitoring for State-of-Charge and Power Capability Prediction
Juang, L. W. (2010) · Minds at UW (University of Wisconsin) · Cited by 12
Machine Learning Approaches for Enhancing the SoH Estimation of LTO Batteries
Dikmen, I. C., Yıldıran, N., & Karadağ, T. (2025) · International Journal of Automotive Science And Technology · doi:10.30939/ijastech..1522403 · Cited by 12
Bauknecht, S., Kowal, J., Bozkaya, B., Settelein, J., & Karden, E. (2022) · Batteries · doi:10.3390/batteries8070066 · Cited by 11
Mussi, M., Pellegrino, L., Restelli, M., & Trovò, F. (2022) · Journal of Energy Storage · doi:10.1016/j.est.2022.105467 · Cited by 11
Juang, L. W., Kollmeyer, P. J., Jahns, T. M., & Lorenz, R. D. (2011) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2011.6064120 · Cited by 11
“Other methods used to infer the SOC include impedance tracking [4] and impedance spectroscopy [5].”
MethodState-of-charge and state-of-health estimating method for lithium-ion batteries
Wu, T.-H., Wang, J.-K., Moo, C., & Kawamura, A. (2016) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2016.7556688 · Cited by 13
“Many SOH estimating methods have been proposed in the literatures, among which, the electrochemical impedance spectroscopy (EIS) and adaptive systems are frequently adopted for evaluating the status of a battery [14]-[15].”
BackgroundRavi, R., & Surendra, U. (2021) · Advances in mechatronics and mechanical engineering (AMME) book series · doi:10.4018/978-1-7998-7626-7.ch001 · Cited by 11
Monitoring techniques for 12-V lead–acid batteries in automobiles
Schoch, E., Königsmann, M., Kizler, J., Schmucker, C., Kronenberg, B., Bremmer, M., Schöttle, J., & Ruch, M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-444-63700-0.00014-3 · Cited by 11
Verbrugge, M. W. (2008) · Modern aspects of electrochemistry · doi:10.1007/978-0-387-49582-8_8 · Cited by 11
Bernard, J., Sciarretta, A., Touzani, Y., & Sauvant-Moynot, V. (2009) · Oil & Gas Science and Technology – Revue d’IFP Energies nouvelles · doi:10.2516/ogst/2009060 · Cited by 11
Automotive Battery State-of-Health Monitoring: a Parity Relation Based Approach
Zhang, X., Grube, R., Shin, K.-K., Salman, M. A., & Conell, R. S. (2009) · IFAC Proceedings Volumes · doi:10.3182/20090630-4-es-2003.00092 · Cited by 11
Su, C., Kang, C., Zhang, Z., & Zhu, H. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793555 · Cited by 10
“The value of SOC is defined as the ratio of current charge with rated charge, and its calculating models include Ampere-hour (Ah) method [3], Discharge-testing method [3], Open-Circuit Voltage (OCV) method [4], internal resistance method [5], Neural Network method [6], Kalman Filtering (KF) method [6,7], Particle Filt…”
MethodSuarez-Hernandez, R., Ramos‐Sánchez, G., Oliver-Tolentino, M. A., & González, I. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.139240 · Cited by 10
Cheng, L., Chen, J., Pu, Y., & Yin, X. (2023) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/acced5 · Cited by 10
Praisuwanna, N., & Khomfoi, S. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6646897 · Cited by 10
State of Charge Estimation Based on Microscopic Driving Parameters for Electric Vehicle's Battery
Yao, E., Wang, M., Song, Y., & Yang, Y. (2013) · Mathematical Problems in Engineering · doi:10.1155/2013/946747 · Cited by 12
“), which mainly include open-circuit voltage (OCV) method [9, 10], terminal voltage method [11], impedance measurement method [12, 13], and impedance spectroscopy method [14, 15].”
MethodClassical EIS and square pattern signals comparison based on a well-known reference impedance
Nazer, R. A., Cattin, V., Granjon, P., Montaru, M., Ranieri, M., & Heiries, V. (2013) · World Electric Vehicle Symposium and Exhibition (EVS) · doi:10.1109/evs.2013.6914874 · Cited by 12
Ranieri, M., Alberto, D., Piret, H., & Cattin, V. (2017) · Microelectronics Reliability · doi:10.1016/j.microrel.2017.06.010 · Cited by 10
Siczek, K. J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816392-4.00016-5 · Cited by 11
High resolution converter for battery impedance spectroscopy
Dam, S. K., & John, V. (2016) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2016.7914335 · Cited by 10
“5) To ensure the validity of linear system assumption, the amplitude of voltage perturbation should not exceed 10 mV/cell [2], [3], [7].”
BackgroundModelling and evaluation of valve-regulated lead-acid batteries
Tenno, A. (2004) · Aaltodoc (Aalto University) · Cited by 10
Sadli, I. (2006) · theses.fr (ABES) · doi:10.70675/5e8e95efz14fcz486czb547zcc2652e10ffe · Cited by 10
Capacity Recovery of a Sulfated Lead-Acid Battery Using Pressure Feedback Charging Control
Shi, Y., Ferone, C. A., & Rahn, C. D. (2012) · ASME Dynamic Systems and Control Conference (DSCC) · doi:10.1115/dscc2012-movic2012-8584 · Cited by 9
State-of-health indication method for Li-Ion batteries
Xia, Z., & Qahouq, J. A. A. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341265 · Cited by 10
“The determination or estimation of State-Of-Health (SOH) of batteries is important for the performance, reliability, and safety of many related applications [1-5].”
BackgroundRecent Trends on Drivetrain Control Strategies and Battery Parameters of a Hybrid Electric Vehicle
Bhaskar, P. B., Deshmukh, S. S., Khannan, P., & Shaik, A. (2019) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2019-28-0155 · Cited by 9
Nwanya, A. C., Ndipingwi, M. M., Ofomatah, A. C., Ezema, F. I., Mâaza, M., & Iwuoha, E. I. (2021) · International Journal of Energy Research · doi:10.1002/er.6594 · Cited by 9
Aloisio, D., Campobello, G., Leonardi, S. G., Sergi, F., Brunaccini, G., Ferraro, M., Antonucci, V., Segreto, A., & Donato, N. (2021) · ACTA IMEKO · doi:10.21014/acta_imeko.v10i2.1043 · Cited by 10
“Since each one of these phenomena are strictly related to temperature, to SoC and to the state of health (SoH) of the cell, then the analysis of the impedance data can be used to monitor the status of the battery [14].”
Alao, O. B., & Barendse, P. (2018) · IEEE PES/IAS PowerAfrica Conference (PowerAfrica) · doi:10.1109/powerafrica.2018.8521149 · Cited by 9
“There has been previous work on using EIS to characterize lead acid and lithium-ion batteries in [3] – [11], [15] – [17].”
BackgroundMethodFarmakis, F. V., de Meatza, I., Subburaj, T., Tsiplakides, D., Argyropoulos, D.-P., Balomenou, S. P., Landa‐Medrano, I., Eguía-Barrio, A., Strataki, N., & Nestoridi, M. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.102989 · Cited by 9
Yang, H., Qiu, Y., & Guo, X. (2015) · Energies · doi:10.3390/en81112322 · Cited by 10
“Generally, three definitions of battery SOH have been reported, including SOH values based on battery impedance [11,12], battery capacity [9], and comprehensive battery parameters such as impedance, capacity, open circuit potential (OCV), charging or discharging current, and temperature (T) [13–17].”
BackgroundBaert, D., & Vervaet, A. A. (2003) · Ghent University Academic Bibliography (Ghent University) · Cited by 9
AC impedance and state-of-charge analysis of alkaline zinc/manganese dioxide primary cells
Rodrigues, S., Munichandraiah, N., & Shukla, A. K. (2000) · Journal of Applied Electrochemistry · doi:10.1023/a:1003986226754 · Cited by 9
Per unit representation of electrical magnitudes in batteries: A tool for comparison and design
Gauchía, L., & Sanz, J. (2008) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.10.019 · Cited by 9
Ali, S. M., Bilal, M., Alharbi, A. A., & Amin, R. U. (2025) · IET Power Electronics · doi:10.1049/pel2.70101 · Cited by 9
Lokeswararao, Y., Viji, M., Budumuru, A. K., & Sudakar, C. (2021) · Materials Today Communications · doi:10.1016/j.mtcomm.2021.102435 · Cited by 8
Fast Estimation of State of Charge for Lithium-Ion Battery
Chen, H.-C., Chou, S.-R., Chen, H. C., Wu, S. L., & Chen, L. R. (2014) · International Symposium on Computer, Consumer and Control · doi:10.1109/is3c.2014.82 · Cited by 8
Battery Impedance Measurement Using Pseudo Random Binary Sequences
Li, Y., Bingham, C. M., Cruz-Manzo, S., Cui, D., & Lv, Y. (2020) · IEEE Student Conference on Electric Machines and Systems (SCEMS) · doi:10.1109/scems48876.2020.9352336 · Cited by 8
“A detailed review of the applicability of impedance measurement as a test of SOC or SOH of battery cells has been given in [4] by F.”
Fonseca, J. M. L., Reddy, S. R. P., Rajashekara, K., & Potti, K. R. R. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3197552 · Cited by 8
“This scenario might lead to different capacitor energy requirements, as the battery impedance is dependent on many factors such as SoC, state-of-health (SoH), and chemistry [21], [22].”
BackgroundHybrid impedance spectroscopy and transients testing methodology
Lagonotte, P., Soulier, F., Thomas, A., & Martémianov, S. (2023) · Journal of Energy Storage · doi:10.1016/j.est.2023.109290 · Cited by 8
Gao, L., Song, Y., & Dougal, R. A. (2005) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2005.1453111 · Cited by 8
ABLE project: Development of an advanced lead-acid storage system for autonomous PV installations
Lemaire, E., Vallvé, X., Pavlov, D., Papazov, G., van der Borg, N., & Sarrau, J.-F. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.04.037 · Cited by 8
An SOH estimation system based on time-constant-ratio measurement
Dung, L.-R., Wu, S.-H., & Yuan, H.-F. (2014) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2014.6864885 · Cited by 8
“It no longer relates to Rohmic.”
BackgroundYan, C., Wu, C. J., Zhuang, Q., Tian, L., Cui, Y., Zhao, X., Ju, Z., & Sun, X. A. (2016) · ChemistrySelect · doi:10.1002/slct.201600584 · Cited by 8
Estimation of Lithium Primary Battery Capacity Based on Pulse Load Test
Sun, Q., Ye, X., Li, H., Li, W., Yuan, R., & Zhai, G. (2021) · International Conference on System Reliability and Safety Engineering (SRSE) · doi:10.1109/srse54209.2021.00031 · Cited by 10
“On the other hand, the pulse load test/DC impedance method is often used in battery internal resistance measurement, battery state characterization, and battery equivalent model establishment [12-13].”
MethodLeaf and hexagonal grid designs for lead-acid battery. An EIS analysis
Calboréan, A., Bruj, O., & Morari, C. (2022) · Journal of Energy Storage · doi:10.1016/j.est.2022.105933 · Cited by 9
C1.1 - Miniaturized Impedance Measurement System for Battery Diagnosis
Tröltzsch, U., & Kanoun, O. (2009) · SENSOR International Conference on Sensors and Measurement Technology (SENSOR) · doi:10.5162/sensor09/v1/c1.1 · Cited by 8
“The large amount of available methods for determining these quantities shows the importance [1, 2, 3].”
BackgroundMethodAutomotive Battery State-of-Health Monitoring Methods
Grube, R. (2008) · CORE Scholar (Wright State University) · Cited by 10
Survey and evaluation of battery monitoring methods and results from user's viewpoint
Waltari, P., & Suntio, T. (1999) · International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intlec.1999.794104 · Cited by 8
MEASUREMENT METHODS | Electrochemical: Impedance Spectroscopy
Stoynov, Z. B., & Vladikova, D. E. (2009) · Elsevier eBooks · doi:10.1016/b978-044452745-5.00068-x · Cited by 8
Li, C., & Zhang, L. (2025) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2025.113041 · Cited by 8
A comprehensive review on Electro Chemical Energy storage systems for Electric Vehicle application
Mukherjee, A., Chatterjee, S., & Pudur, R. (2025) · Journal of Energy Storage · doi:10.1016/j.est.2025.118620 · Cited by 8
Yıldıran, N., Dikmen, I. C., & Karadağ, T. (2024) · International Artificial Intelligence and Data Processing Symposium (IDAP) · doi:10.1109/idap64064.2024.10711165 · Cited by 8
Impedance-Based Battery Management for Metal-O2Systems
Christensen, A. E., Højberg, J., Norby, P., & Vegge, T. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0481510jes · Cited by 8
Detection on SOC of VRLA battery with EIS
Wu, P.-C., Hsu, W.-C., & Chen, J.-F. (2013) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec.2013.6687629 · Cited by 7
Thenaisie, G., Park, C.-H., Cho, J., & Lee, S.-G. (2020) · Measurement · doi:10.1016/j.measurement.2020.107637 · Cited by 7
Lead-acid Battery State-of-Health Evaluation with Short Discharge Method
Mohsin, M. R., Picot, A., & Maussion, P. (2021) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped51010.2021.9605545 · Cited by 7
“Electrochemical Impedance Spectroscopy (EIS) is a very quality technique for measuring battery performance [21].”
BackgroundImpact of Cell Replacement on the State-of-Health for Parallel Li-Ion Battery Pack
Huynh, P.-L., Mohareb, O. A., Grimm, M., Mäurer, H. J., Richter, A., & Reuss, H. C. (2014) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2014.7007084 · Cited by 9
Liu, Y. J., & Tan, G. (2017) · Journal of Renewable and Sustainable Energy · doi:10.1063/1.4992815 · Cited by 8
Energy Usage Profiling for Virtualized Single Board Computer Clusters
Sagkriotis, S. G., Anagnostopoulos, C. B., & Pezaros, D. P. (2019) · IEEE Symposium on Computers and Communications (ISCC) · doi:10.1109/iscc47284.2019.8969611 · Cited by 7
“, [17]), can be dependent on factors like the state of health of a battery, the specific battery model, etc.”
BackgroundPrognostic Modeling of Performance Degradation in Energy Storage by Lithium-ion Batteries
Wang, P. E., & Gao, R. X. (2019) · Procedia Manufacturing · doi:10.1016/j.promfg.2019.06.156 · Cited by 7
Monitoring sealed automotive lead-acid batteries by sparse-impedance spectroscopy
Hariprakash, B., Martha, S. K., & Shukla, A. K. (2003) · Journal of Chemical Sciences · doi:10.1007/bf02708238 · Cited by 8
Study of Discharge Characteristics of Sodium/NiCl2Cell Using Electrochemical Impedance Spectroscopy
Wang, S., Pan, Z., Zhao, J., Huang, Q., Shapiro, A. P., Sarrafi-Nour, R., & Zappi, G. D. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.041303jes · Cited by 7
Estimation of SOC and SOH of Li-Ion Batteries
Prashanth, K. I., Dinesh Rao, B., & Sharma, A. (2014) · International Journal of Computer Applications · doi:10.5120/18194-9111 · Cited by 7
“Various equivalent circuit models have been combined estimation of SOC to evaluate the state of charge of LithiumIon batteries [8]-[9].”
Pulido, Y. F., Blanco, C., Anseán, D., Gonzalez, M., Viera, J. C., & Garcia, V. M. (2017) · IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) · doi:10.1109/eeeic.2017.7977469 · Cited by 7
Caractérisation et modélisation de composants de stockage électrochimique et électrostatique
Devillers, N. (2012) · theses.fr (ABES) · doi:10.70675/02f8088ez21a6z484fzab61zd6d27ddea572 · Cited by 25
The Zinc/Bromine Flow Battery: Fundamentals and Novel Materials for Technology Advancement
Rajarathnam, G. P. (2016) · The Sydney eScholarship Repository (The University of Sydney) · Cited by 11
Normalized least mean squares observer for battery parameter estimation
Krüger, E., Tran, Q. T., & Mamadou, K. (2015) · doi:10.1109/ptc.2015.7232752 · Cited by 8
“Subsequently, the open-circuit voltage and impedance parameters are determined by voltage measurement after relaxation and impedance measurement or impedance spectroscopy, respectively [8][9].”
MethodNoppakunkajorn, J., Baroudi, O., Cox, R. W., & Mandal, L. P. (2012) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2012.6389241 · Cited by 6
“The literature includes numerous studies on the kinetics of electrochemical processes in batteries [8], [11]-[14].”
BackgroundNew lead-acid battery management system based on generator regulation
Zhang, G. Y., Zhao, X., Qiang, J., Tian, F., & Yang, L. (2012) · International Journal of Automotive Technology · doi:10.1007/s12239-012-0066-8 · Cited by 6
“The battery inter resistance (Rint) is an indicator of the SOH of the battery (Huet, 1998; Meissner and Richter, 2001; Omar et al., 2010; Smith et al., 2002).”
Background
Metadata
- Authors
- Huet, F.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Corresponding author
- Huet, F.
- ORCID
- Huet, F.
- Venue
- Journal of Power Sources
- Publisher
- Elsevier BV
- Published
- 1998-01
- Volume
- 70
- Issue
- 1
- Pages
- 59-69
- ISSN
- 0378-7753 (ISSN-L)
- OpenAlex
- W2046464001
- Cited by
- 593
- References
- 35
- Citations by year
- 2026: 13 · 2025: 20 · 2024: 14 · 2023: 22 · 2022: 26 · 2021: 34 · 2020: 19 · 2019: 36 · 2018: 25 · 2017: 39 · 2016: 31 · 2015: 40 · 2014: 43 · 2013: 36 · 2012: 31
- FWCI
- 15.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Power Sources (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Engineering › Automotive Engineering › Battery Modeling and Management
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Battery Materials
- Physical Sciences › Materials Science › Metals and Alloys › Extraction and Separation Processes
- Keywords
- impedance measurement, state of charge, health status (engineering condition monitoring), rechargeable batteries, lead-acid batteries, nickel-cadmium batteries, battery testing, rate capacity, battery health monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.