CoChat

An Electrochemical Impedance Spectrum-Based State of Health Differential Indicator with Reduced Sensitivity to Measurement Errors for Lithium–Ion Batteries

Open access
Abu Qahouq, Jaber · 2024 · Batteries

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index; 13 of the 27 sources its claims cite were checked for support.

Abstract

As the use of electrochemical batteries, especially lithium–ion (Li-Ion) batteries, increases due to emerging applications and expanding markets, the accurate and fast estimation of their state of health (SOH) is becoming increasingly important. The accuracy of the SOH estimation is highly dependent on the correlation strength between the used indicator and SOH and the accuracy of the SOH indicator measurement. This paper presents a new differential indicator which has a strong and consistent correlation with the SOH of Li-Ion batteries, based on a new Electrochemical Impedance Spectrum (EIS) Phase–Magnitude relationship. It is shown in this paper that the EIS Phase–Magnitude relationship exhibits a phase-based differential impedance magnitude SOH indicator between a first-phase peak point and a last-phase valley point. Because of the differential nature of this SOH indicator and because the two impedance values are measured at a phase peak point and a valley phase point regardless of the phase absolute values, the effect of impedance measurement shift/offset (error) on SOH estimation is reduced. This supports the future development of more accurate and faster online and offline SOH estimation algorithms and systems that have a higher immunity to impedance measurement shift/offset (error). Furthermore, in this work, the EIS was measured for a lithium–ion battery that was down to a ~15% SOH, which was not only used to support the conclusions of this paper, but also helped in filling a gap in the literature for EIS data under deep/high degradation levels.

Overview

CoChat Summary

TL;DR

The paper introduces a differential state-of-health (SOH) indicator, ΔZ_PM-Diff, derived from an EIS Phase-Magnitude relationship between the first phase peak and last phase valley, and reports a strong, consistent correlation with Li-ion SOH. Its differential nature is intended to reduce sensitivity to impedance measurement shift/offset error, validated on a Tenergy cell aged to ~15% SOH and Samsung 35E data down to ~89% SOH.

Key findings

  • ΔZ_PM-Diff = |Z_phase-peak − Z_phase-valley| increases as SOH decreases, and the paper reports a strong and consistent correlation with remaining-capacity-based SOH.
  • The differential indicator is reported to have higher immunity to measurement shift/offset error because the two impedance values are taken at a phase peak point and a phase valley point regardless of the phase absolute values.
  • For a Tenergy ICR 18650-2600 Li-ion cell aged down to ~15% SOH, a simple linear approximation gave R² = 0.9529; for a Samsung 35E Li-ion cell down to ~89% SOH, R² = 0.9831. Table 1 reports Tenergy order-1 down to 15% SOH: RMSE 5.4%, MAPE 12.4%; order-3 down to 15% SOH: RMSE 4.4%, MAPE 8.9%; order-1 down to 50% SOH: RMSE 0.56%, MAPE 0.74%; Samsung order-1 down to 89% SOH: RMSE 0.43%, MAPE 0.47%; order-3: RMSE 0.01%, MAPE 0.01%.
  • The relationship is described as almost linear for SOH values ≥50%, while SOH values <50% exhibit nonlinearity.

Methods

  • A Tenergy ICR 18650-2600 Li-ion cell was aged by charge/discharge cycling at 2.6 A (1 C rate): CC charge at 2.6 A to 4.2 V, then CV until current reached 50 mA; discharge at 2.6 A to 2.7 V. The cell rested 12 h before measurements. EIS was measured with a Gamry Interface 5000E potentiostat over 10 mHz–10 kHz, and SOH was calculated from remaining capacity using Coulomb counting. Data were taken at 25 °C.
  • Additional validation used published EIS and estimated capacity data for a Samsung 35E Li-ion cell from NASA researchers in reference [3], with EIS data estimated from a Nyquist plot and SOH values estimated from a discharged-capacity plot, available down to only ~89% SOH.
  • The analysis computes ΔZ_PM-Diff from the first-phase peak point and last-phase valley point of the Phase-Magnitude relationship, compares it with SOH, and evaluates linear and polynomial approximations using R², RMSE, and MAPE.

Limitations

  • Stated: the data were taken at 25 °C; if a battery is not under controlled temperature, SOH estimation models and algorithms need to account for temperature variations.
  • Stated: the Samsung 35E validation is limited to ~89% SOH because the published data were available only down to that level, and the EIS and SOH values were estimated from plots in reference [3].
  • Stated/evident: simple linear or polynomial approximation may not be viable or sufficient in most cases, especially below 50% SOH and for batteries in power-demanding, variable, or harsh environments, where advanced algorithms would likely be needed; future work includes deep-ageing data from other battery types and at different temperatures.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/batteries10100368

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

7 Valid · 5 Not valid · 2 Not checked · 27 Own results and interpretations

8 more claims

Create a free account to see all 41 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 12
  • Probably not a substantial claim. 20
  • Borderline: one of the tests for a substantial claim is unclear. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 33 references

Cited by

See all 13

Metadata

Authors
Abu Qahouq, J.
Affiliations
Department of Electrical and Computer Engineering, College of Engineering, The University of Alabama, Tuscaloosa, AL 35487, USA
Venue
Batteries
Publisher
MDPI AG
Published
2024-10-16
Volume
10
Issue
10
Pages
368
ISSN
2313-0105 (ISSN-L)
OpenAlex
W4403491648
Cited by
13
References
32
Citations by year
2026: 6 · 2025: 7
FWCI
1.40
Type
journal article
Language
en
Open access
Locations
  • Batteries (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
National Science Foundation (NSF, United States) (2213918)
Topics
  • Physical Sciences › Engineering › Automotive Engineering › Battery Modeling and Management
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Battery Materials
  • Physical Sciences › Materials Science › Metals and Alloys › Extraction and Separation Processes
Keywords
lithium-ion batteries, state of health estimation, electrochemical impedance spectroscopy, measurement error robustness, battery degradation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-08, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-08 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Electrochemical Impedance Spectrum-Based State of Health Differential Indicator with Reduced Sensitivity to Measurement Errors for Lithium–Ion Batteries. https://app.cochat.ai/papers/10.3390/batteries10100368
The paper
Abu Qahouq, J. (2024). An Electrochemical Impedance Spectrum-Based State of Health Differential Indicator with Reduced Sensitivity to Measurement Errors for Lithium–Ion Batteries. Batteries. https://doi.org/10.3390/batteries10100368

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.