A simple LC method with UV detection for the analysis of creatine and creatinine and its application to several creatine formulations

Dash, Alekha K, Sawhney, Angeli·2002·Journal of Pharmaceutical and Biomedical Analysis

Abstract

The objective of this study was to develop a simple and sensitive LC method for the determination of creatine and creatinine in various creatine supplement formulations. The chromatographic system comprised of a LC-600 pump, SCL-6B system controller, and SPD-6AV detector (Shimadzu, Japan). The mobile phase consisted of 0.045 M ammonium sulfate in water. The chromatographic separation was achieved at ambient temperature on a Betabasic C-18 column (250 x 4.6 mm, Keystone Sci.). The flow rate was maintained at 0.75 ml/min and effluents are monitored at 205 nm. 4-(2-Aminoethyl)benzene sulfonamide was used as an internal standard (IS). This method required less than 7 min of chromatographic time. The standard curves were linear over the concentration range of 1-100 microg/ml for creatine and 2-100 microg/ml for creatinine, respectively. The relative standard deviations (RSD) for the within-day and day-to-day precision for creatine were within 1.0-4.6 and 2.2-4.7%, respectively. The RSD for the accuracy of creatine assay was in the range of 2.4-4.7%. The RSD values for the within-day precision, day-to-day precision and accuracy for creatinine validation were 1.7-4.4, 2.3-5.4 and 2.4-4.8%, respectively. This method was used to determine: (i) the creatine concentration in various marketed products; (ii) saturated solubility of various creatine salts; and (iii) stability of creatine in aqueous solution. In conclusion, a simple and sensitive LC method with UV detection was developed fo…

Integrity signals

Registry

Crossref · 10.1016/s0731-7085(02)00167-x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dash, A. K., & Sawhney, A.
Affiliations
Creighton University (US)
Corresponding author
Dash, Alekha K
Venue
Journal of Pharmaceutical and Biomedical Analysis
Publisher
Elsevier BV
Published
2002-07
Volume
29
Issue
5
Pages
939-945
ISSN
0731-7085 (ISSN-L)
OpenAlex
W1977360630
Cited by
58
References
1
Citations by year
2026: 1 · 2025: 3 · 2024: 2 · 2023: 1 · 2022: 3 · 2020: 4 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 2 · 2012: 2
FWCI
4.20
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Pharmaceutical and Biomedical Analysis (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Food and Agricultural Sciences
Keywords
creatine, creatinine, creatine monohydrate, UV detection, internal standard
MeSH terms
Chromatography, High Pressure Liquid, Creatine, Creatinine, Sensitivity and Specificity, Spectrophotometry, Ultraviolet, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review