Cited by 11Analytical Methods in PharmaceuticalsThermal and Kinetic AnalysisCrystallization and Solubility Studies

Effect of water activity and temperature on the stability of creatine during storage

Uzzan, Michael, Nechrebeki, Jacob, Zhou, Peng, Labuza, Theodore P.·2009·Drug Development and Industrial Pharmacy

Abstract

Creatine degradation to creatinine, which has no biological activity, in combinations of glycerol and pH 4.0 buffer solutions followed first-order kinetics up to a point where degradation started to level off, generally beyond the first half-life. Practical data are reported for a wide range of water activity (a(w)) values (0.31-0.983) at 4 degrees C, 23 degrees C, and 35 degrees C. Creatine degradation did not exhibit a dilution effect, that is a decrease in rate about an a(w) of 0.7, as is found for both microbiological growth and chemical reactions in semisolid food matrix systems. The temperature dependence obeyed the Arrhenius relationship with an energy of activation of about 20 kcal/mol at a(w) >or= 0.68 increasing to 23 kcal/mole below that a(w). In addition, a semilog plot of half-life as a function of a(w) at each temperature follows a predicted straight line. The pH and assumed liquid viscosity increase through increased glycerol concentration were not able to completely explain the decrease in rate of degradation as a function of a(w). Furthermore, we confirmed that creatine stability in the crystal form is very high as long as it does not reach the deliquescence state.

Integrity signals

Registry

Crossref · 10.1080/03639040902755197

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Cites

Flagged first, then by citations

Research works printed but not linked: 5

  1. Stryer L, 1995, Biochemistry
  2. Nigel JF, 1998, Clinica Chimica Acta, 175, 199
  3. Labuza TP, 1980, Food Technol, 34, 36
  4. Katsaboxakis K, 1998, J Food Sci, 10, 17
  5. Bell LN, 1991, Cryo Letters, 12, 235

Cited by

Sorted by citations

Authors
Uzzan, M., Nechrebeki, J., Zhou, P., & Labuza, T. P.
Affiliations
  • University of Minnesota (US)
  • Jiangnan University (CN)
Corresponding author
Uzzan, Michael
Venue
Drug Development and Industrial Pharmacy
Published
2009-07-28
Volume
35
Issue
8
Pages
1003-1008
ISSN
  • 0363-9045 (ISSN-L)
  • 1520-5762
OpenAlex
W2097570191
Cited by
11
References
13
Citations by year
2022: 2 · 2021: 1 · 2019: 1 · 2018: 1 · 2016: 3 · 2015: 2
FWCI
0.32
Type
journal article
Language
en
Open access
closed
Locations
  • Drug Development and Industrial Pharmacy (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal and Kinetic Analysis
  • Physical Sciences › Materials Science › Materials Chemistry › Crystallization and Solubility Studies
Keywords
creatine, creatinine, water activity, temperature dependence, storage stability, Arrhenius equation, activation energy, half-life, glycerol, pH, deliquescence, first-order kinetics
MeSH terms
Creatine, Crystallization, Drug Stability, Drug Storage, Glycerol, Half-Life, Hydrogen-Ion Concentration, Kinetics, Temperature, Viscosity, Water

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review