Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,026

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay

Open access
Auricchio, Angelo, Stellbrink, Christoph, Sack, Stefan, Block, Michael, Vogt, J.ürgen, Bakker, Patricia, Huth, Christof, Schöndube, Friedrich, Wolfhard, Ulrich, Böcker, Dirk, Krahnefeld, Olaf, Kirkels, Hans·2002·Journal of the American College of Cardiology

Abstract

OBJECTIVES We sought to compare the short- and long-term clinical effects of atrial synchronous pre-excitation of one (univentricular) or both ventricles (biventricular), that provide cardiac resynchronization therapy (CRT). BACKGROUND In patients with heart failure (HF) who have a ventricular conduction delay, CRT improves systolic hemodynamic function. The clinical benefit of CRT is still being investigated. METHODS Forty-one patients were randomized to four weeks of first treatment with biventricular or univentricular stimulation, followed by four weeks without treatment, and then four weeks of a second treatment with the opposite stimulation. The best CRT stimulation was continued for nine months. Cardiac resynchronization therapy was optimized by hemodynamic testing at implantation. The primary end points were exercise capacity measures. Data were analyzed by two-way repeated-measures analysis of variance. RESULTS The left ventricle was selected for univentricular pacing in 36 patients. The clinical effects of univentricular and biventricular CRT were not significantly different. The results of each method were pooled to assess sequential treatment effects. Oxygen uptake during bicycle exercise increased from 9.48 to 10.4 ml/kg/min at the anaerobic threshold (p = 0.03) and from 12.5 to 14.3 ml/kg/min at peak exercise (p < 0.001) with the first treatment, and from 10.0 to 10.7 ml/kg/min at the anaerobic threshold (p = 0.2) and from 13.4 to 15.2 ml/kg/min at peak exercise (p = 0.002) with the second treatment. The 6-min walk distance increased from 342 m at baseline to 386 m after the first treatment (p < 0.001) and to 416 m after the second treatment (p = 0.03). All improvements persisted after 12 months of therapy. CONCLUSIONS Cardiac resynchronization therapy produces a long-term improvement in the clinical symptoms of patients with HF who have a ventricular conduction delay. The differences between optimized biventricular and univentricular therapy appear to be small for short-term treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(02)01895-8

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 1,026

Metadata

Authors
Auricchio, A., Stellbrink, C., Sack, S., Block, M., Vogt, J. Ü., Bakker, P., Huth, C., Schöndube, F., Wolfhard, U., Böcker, D., Krahnefeld, O., & Kirkels, H.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2002-06
Volume
39
Issue
12
Pages
2026-2033
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2164427485
Cited by
1,026
References
2
FWCI
45.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay. https://app.cochat.ai/papers/10.1016/s0735-1097(02)01895-8
The paper
Auricchio, A., Stellbrink, C., Sack, S., Block, M., Vogt, J. Ü., Bakker, P., Huth, C., Schöndube, F., Wolfhard, U., Böcker, D., Krahnefeld, O., & Kirkels, H. (2002). long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(02)01895-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.