Discrepancies between catheter and Doppler estimates of valve effective orifice area can be predicted from the pressure recovery phenomenon
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gorlin, R., & Gorlin, S. G. (1951) · American Heart Journal · doi:10.1016/0002-8703(51)90002-6 · Cited by 1,778 · cited 1×
“EOAcath Q 50TPGnet [ 2 ] Recently, we proposed a new index based on EOADop and aortic cross-sectional area (AA) that takes into account the pressure recovery phenomenon.”
MethodACC/AHA guidelines for the management of patients with valvular heart disease
Bonow, R., Carabello, B., de Leon, A., Edmunds, L. H., Fedderly, B., Freed, M., Gaasch, W., McKay, C., Nishimura, R., O’Gara, P., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00454-9 · Cited by 1,134
Skjaerpe, T., Hegrenaes, L., & Hatle, L. (1985) · Circulation · doi:10.1161/01.cir.72.4.810 · Cited by 560
The natural history of aortic valve stenosis
Horstkotte, D., & Loogen, F. (1988) · European Heart Journal · doi:10.1093/eurheartj/9.suppl_e.57 · Cited by 457
Spontaneous course of aortic valve disease
TURINA, J., HESS, O., SEPULCRI, F., & KRAYENBUEHL, H. P. (1987) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a062307 · Cited by 414
Oh, J. K., Taliercio, C. P., Holmes, D. R., Reeder, G. S., Bailey, K. R., Seward, J. B., & Tajik, A. J. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90286-0 · Cited by 413
Determination of the stenotic aortic valve area in adults using Doppler echocardiography
Otto, C. M., Pearlman, A. S., Comess, K. A., Reamer, R. P., Janko, C. L., & Huntsman, L. L. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80460-0 · Cited by 391 · cited 1×
“However, although some investigators have found a relatively good agreement between Doppler and catheter EOA measurements (4,5,20,21), others have reported important discrepancies, and in the latter studies, the catheter EOAs were usually higher than the Doppler EOAs (9,22–27).”
ResultAssessment of Aortic Valve Stenosis Severity: A New Index Based on the Energy Loss Concept
Garcia, D., Pibarot, P., Dumesnil, J. G., Sakr, F., & Durand, L.-G. (2000) · Circulation · doi:10.1161/01.cir.101.7.765 · Cited by 347
Self-citationBaumgartner, H., Stefenelli, T., Niederberger, J., Schima, H., & Maurer, G. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00066-2 · Cited by 316 · cited 1×
“It should be noted that according to fluid mechanics considerations and previous in vivo studies (13,16,29), the diameter of the aorta used to calculate ELCo should be measured at the sino-tubular junction (i.”
ResultSoni, A. V., & Miller, S. W. (2009) · Cardiac Imaging · doi:10.1016/b978-0-323-05527-7.50013-5 · Cited by 311
Cited by
Lancellotti, P., Pibarot, P., Chambers, J., Edvardsen, T., Delgado, V., Dulgheru, R., Pepi, M., Cosyns, B., Dweck, M. R., Garbi, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew025 · Cited by 567
Self-citationOtto, C. M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.002 · Cited by 499
Briand, M., Dumesnil, J. G., Kadem, L., Tongue, A. G., Rieu, R., Garcia, D., & Pibarot, P. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.081 · Cited by 493
Self-citationDumesnil, J. G., Pibarot, P., & Carabello, B. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp361 · Cited by 329
Self-citationMinners, J., Allgeier, M., Gohlke-Baerwolf, C., Kienzle, R.-P., Neumann, F.-J., & Jander, N. (2010) · Heart · doi:10.1136/hrt.2009.181982 · Cited by 252
“Third, an overestimation of AVA during cardiac catheterisation may result from pressure recovery.(11) With respect to cut-off values for the severity of aortic valve stenosis more conservative values may be appropriate for an AVA derived from echocardiography than cardiac catheterisation.”
BackgroundLiberman, M., Bassi, E., Martinatti, M. K., Lario, F. C., Wosniak, J., Pomerantzeff, P. M. A., & Laurindo, F. R. M. (2008) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.156745 · Cited by 225
Improving Assessment of Aortic Stenosis
Pibarot, P., & Dumesnil, J. G. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.078 · Cited by 191
Self-citationAccurate Assessment of Aortic Stenosis: A Review of Diagnostic Modalities and Hemodynamics
Saikrishnan, N., Kumar, G., Sawaya, F. J., Lerakis, S., & Yoganathan, A. P. (2014) · Circulation · doi:10.1161/circulationaha.113.002310 · Cited by 182
“In addition, values derived from catheterization are always lower than echo-derived values because of pressure recovery.(18,31,32) Doppler echocardiography measures ΔP max from the velocity measured at the VC, whereas catheterization measures ΔP rec .”
BackgroundDyverfeldt, P., Hope, M. D., Tseng, E. E., & Saloner, D. (2013) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2012.07.017 · Cited by 174
Impact of systemic hypertension on the assessment of aortic stenosis
Kadem, L., Dumesnil, J. G., Rieu, R., Durand, L.-G., Garcia, D., & Pibarot, P. (2005) · Heart · doi:10.1136/hrt.2003.030601 · Cited by 170
“On the other hand, when systemic hypertension was induced downstream from this severe AS, significant decreases in catheter derived TPGptop (group A: 276 (15)%; group B: 261 (29)%; all animals: 270 (23)%), TPGmax (group A: 243 (20)%; group B: 236 (20)%; all animals: 240 (20)%), and TPGmean (group A: 247 ( 22 )%; group…”
Self-citation
Metadata
- Authors
- Garcia, D., Dumesnil, J. G., Durand, L.-G., Kadem, L., & Pibarot, P.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2003-02
- Volume
- 41
- Issue
- 3
- Pages
- 435-442
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2143327652
- Cited by
- 239
- References
- 20
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.