The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A new pacemaker algorithm for the treatment of atrial fibrillation
Open accessAbstract
OBJECTIVES The Atrial Dynamic Overdrive Pacing Trial (ADOPT) was a single blind, randomized, controlled study to evaluate the efficacy and safety of the atrial fibrillation (AF) Suppression Algorithm (St. Jude Medical Cardiac Rhythm Management Division, Sylmar, California) in patients with sick sinus syndrome and AF. BACKGROUND This algorithm increases the pacing rate when the native rhythm emerges and periodically reduces the rate to search for intrinsic atrial activity. METHODS Symptomatic AF burden (percentage of days during which symptomatic AF occurred) was the primary end point. Patients underwent pacemaker implantation, were randomized to DDDR with the algorithm on (treatment) or off (control), and were followed for six months. RESULTS Baseline characteristics and antiarrhythmic drugs used were similar in both groups. The percentage of atrial pacing was higher in the treatment group (92.9% vs. 67.9%, p < 0.0001). The AF Suppression Algorithm reduced symptomatic AF burden by 25% (2.50% control vs. 1.87% treatment). Atrial fibrillation burden decreased progressively in both groups but was lower in the treatment group at each follow-up visit (one, three, and six months) (p = 0.005). Quality of life scores improved in both groups. The mean number of AF episodes (4.3 +/- 11.5 control vs. 3.2 +/- 8.6 treatment); total hospitalizations (17 control vs. 15 treatment); and incidence of complications, adverse events, and deaths were not statistically different between groups. CONCLUSIONS The ADOPT demonstrated that overdrive atrial pacing with the AF Suppression Algorithm decreased symptomatic AF burden significantly in patients with sick sinus syndrome and AF. The decrease in relative AF burden was substantial (25%), although the absolute difference was small (2.50% control vs. 1.87% treatment).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Kinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_1-199601010-00003 · Cited by 245
The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice
Zimetbaum, P. J., & Josephson, M. E. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-10-199905180-00020 · Cited by 139
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Metadata
- Authors
- Carlson, M. D., Ip, J., Messenger, J., Beau, S., Kalbfleisch, S., Gervais, P., Cameron, D. A., Duran, A., Val-Mejias, J., Mackall, J., & Gold, M.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2003-08
- Volume
- 42
- Issue
- 4
- Pages
- 627-633
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2157905591
- Cited by
- 235
- References
- 3
- FWCI
- 14.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new pacemaker algorithm for the treatment of atrial fibrillation. https://app.cochat.ai/papers/10.1016/s0735-1097(03)00780-0
- The paper
- Carlson, M. D., Ip, J., Messenger, J., Beau, S., Kalbfleisch, S., Gervais, P., Cameron, D. A., Duran, A., Val-Mejias, J., Mackall, J., & Gold, M. (2003). A new pacemaker algorithm for the treatment of atrial fibrillation. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(03)00780-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.