The DOI matches its Crossref record; 64 of the 65 references it cites were found in a registry or an index.
The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice
Abstract
PURPOSE: To evaluate the efficacy of various ambulatory electrocardiographic monitors for the diagnosis of arrhythmia-related disorders and to provide recommendations for their use in clinical practice. DATA SOURCES: Studies published since 1988 were identified through search of the MEDLINE database. STUDY SELECTION: Studies that met methodologic criteria for minimal bias and had clinical relevance were selected. DATA EXTRACTION: Descriptive and analytic data from each study. DATA SYNTHESIS: Ambulatory electrocardiographic monitors, specifically transtelephonic continuous-loop event recorders, are highly effective for establishing a diagnosis in patients with palpitations but are less effective for establishing a diagnosis in patients with syncope. Clinicians may use these devices to monitor for nonsustained ventricular tachycardia in patients at potentially high risk for sudden arrhythmic death; however, few data are available to support this practice. Ambulatory monitors are useful for assessment of the safety and efficacy of antiarrhythmic medications and the recurrence of symptomatic supraventricular arrhythmias. New ambulatory arrhythmia monitoring devices are being developed that may facilitate outpatient management of chronic cardiac disease. CONCLUSIONS: Ambulatory electrocardiographic monitors, particularly transtelephonic continuous-loop event recorders, aid in the diagnosis of symptomatic arrhythmias. These devices are also useful for monitoring the effectiveness and safety of antiarrhythmic medications. Guidelines are lacking for use of these devices to assess prognosis in patients at potential risk for sudden arrhythmic death.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In patients with palpitations of unknown origin, Holter monitoring has displayed a rather low sensitivity value (33-35%).81”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [81]
Citations
Cites
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Cohn, J. N., Johnson, G., Ziesche, S., Cobb, F., Francis, G., Tristani, F., Smith, R., Dunkman, W. B., Loeb, H., Wong, M., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199108013250502 · Cited by 2,833
Risk Stratification and Survival after Myocardial Infarction
The Multicenter Postinfarction Research Group (1983) · New England Journal of Medicine · doi:10.1056/nejm198308113090602 · Cited by 1,599
Nolan, J., Batin, P. D., Andrews, R., Lindsay, S. J., Brooksby, P., Mullen, M., Baig, W., Flapan, A. D., Cowley, A., Prescott, R. J., et al. (1998) · Circulation · doi:10.1161/01.cir.98.15.1510 · Cited by 1,179
Randomised trial of low-dose amiodarone in severe congestive heart failure
Doval, H., Nul, D. R., Grancelli, H., Perrone, S. V., Bortman, G., & Curiel, R. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91895-3 · Cited by 913
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
Wigle, E. D., Rakowski, H., Kimball, B. P., & Williams, W. G. (1995) · Circulation · doi:10.1161/01.cir.92.7.1680 · Cited by 775
Management of Patients With Atrial Fibrillation
Prystowsky, E. N., Benson, D. W., Fuster, V., Hart, R. G., Kay, G. N., Myerburg, R. J., Naccarelli, G. V., & Wyse, D. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1262 · Cited by 638
Antiarrhythmic drug therapy and cardiac mortality in atrial fibrillation
Flaker, G. C., Blackshear, J. L., McBride, R., Kronmal, R. A., Halperin, J. L., & Hart, R. G. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90003-6 · Cited by 633
Research works printed but not linked: 2
- Kus T, 1995, Can J Cardiol, 11, 891
- Maron BJ, 1992, Circulation, 85, I57
Cited by
Sorted by citations
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,772
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,496
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 748
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 550
Metadata
- Authors
- Zimetbaum, P. J., & Josephson, M. E.
- Affiliations
- Beth Israel Deaconess Medical Center (US)
- Corresponding author
- Zimetbaum, Peter J.
- ORCID
- Zimetbaum, Peter J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1999-05-18
- Volume
- 130
- Issue
- 10
- Pages
- 848-856
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2066069714
- Cited by
- 139
- References
- 65
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 1 · 2022: 4 · 2021: 6 · 2020: 4 · 2019: 5 · 2018: 7 · 2017: 6 · 2016: 7 · 2015: 1 · 2014: 2 · 2013: 7 · 2012: 8
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- Holter monitoring, arrhythmia diagnosis, palpitations, syncope, non-sustained ventricular tachycardia, sudden arrhythmic death, supraventricular arrhythmias, general practice
- MeSH terms
- Algorithms, Anti-Arrhythmia Agents, Arrhythmias, Cardiac, Heart Diseases, Humans, Risk Factors, Syncope, Medical Laboratory Science, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice. https://app.cochat.ai/papers/10.7326/0003-4819-130-10-199905180-00020
- The paper
- Zimetbaum, P. J., & Josephson, M. E. (1999). The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-130-10-199905180-00020