The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Interactions Between Microbubbles and Ultrasound: In Vitro and In Vivo Observations
Open accessAbstract
OBJECTIVES We attempted to examine the interactions between ultrasound and microbubbles. BACKGROUND The interactions between microbubbles and ultrasound are poorly understood. We hypothesized that 1) ultrasound destroys microbubbles, and 2) this destruction can be minimized by limiting the exposure of microbubbles to ultrasound. METHODS We performed in vitro and in vivo experiments in which microbubbles were insonated at different frequencies, transmission powers and pulsing intervals. Video intensity decay was measured in vitro and confirmed by measurements of microbubble size and concentrations. Peak video intensity and mean microbubble myocardial transit rates were measured in vivo. RESULTS Imaging at lower frequencies and higher transmission powers resulted in more rapid video intensity decay (p = 0.01), and decreasing exposure of microbubbles to ultrasound minimized their destruction in vitro. Although these effects were also noted in vivo with venous injections of microbubbles, they were not seen with aortic root or direct coronary artery injections. CONCLUSIONS Ultrasound results in microbubble destruction that is more evident at lower frequencies and higher acoustic powers. Reducing the exposure of microbubbles to ultrasound minimizes their destruction. This effect is most marked in vivo with venous rather than aortic or direct coronary injections of microbubbles. These findings could lead to effective strategies for myocardial perfusion imaging with venous injections of microbubbles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Keller, M. W., Segal, S. S., Kaul, S., & Duling, B. (1989) · Circulation Research · doi:10.1161/01.res.65.2.458 · Cited by 267
Self-citationPrinciples and recent developments in ultrasound contrast agents
de Jong, N., Ten Cate, F. J., Lancée, C. T., Roelandt, J. R. T. C., & Bom, N. (1991) · Ultrasonics · doi:10.1016/0041-624x(91)90030-c · Cited by 236
Simulated Capillary Blood Flow Measurement Using a Nonlinear Ultrasonic Contrast Agent
Schrope, B., Newhouse, V. L., & Uhlendorf, V. (1992) · Ultrasonic Imaging · doi:10.1177/016173469201400204 · Cited by 185
Second harmonic imaging of an intravenously administered echocardiographic contrast agent
Mulvagh, S. L., Foley, D. A., Aeschbacher, B. C., Klarich, K. K., & Seward, J. B. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00619-2 · Cited by 141
Crum, L. A., Roy, R. A., Dinno, M. A., et al. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.402638 · Cited by 85
Continuous-flow, resistive-particle counting
Gear, A. R. L. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90539-x · Cited by 10
Cited by
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Self-citationMicrobubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Echocardiographic Destruction of Albumin Microbubbles Directs Gene Delivery to the Myocardium
Shohet, R. V., Chen, S., Zhou, Y.-T., Wang, Z., Meidell, R. S., Unger, R. H., & Grayburn, P. A. (2000) · Circulation · doi:10.1161/01.cir.101.22.2554 · Cited by 446
Price, R. J., Skyba, D. M., Kaul, S., & Skalak, T. C. (1998) · Circulation · doi:10.1161/01.cir.98.13.1264 · Cited by 393
Self-citationWood, R. J., Lee, J., & Bussemaker, M. J. (2017) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2017.03.030 · Cited by 340
Metadata
- Authors
- Wei, K., Skyba, D. M., Firschke, C., Jayaweera, A. R., Lindner, J. R., & Kaul, S.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1997-04
- Volume
- 29
- Issue
- 5
- Pages
- 1081-1088
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2010234990
- Cited by
- 282
- References
- 6
- FWCI
- 27.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interactions Between Microbubbles and Ultrasound: In Vitro and In Vivo Observations. https://app.cochat.ai/papers/10.1016/s0735-1097(97)00029-6
- The paper
- Wei, K., Skyba, D. M., Firschke, C., Jayaweera, A. R., Lindner, J. R., & Kaul, S. (1997). Interactions Between Microbubbles and Ultrasound: In Vitro and In Vivo Observations. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(97)00029-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.