The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Simulated Capillary Blood Flow Measurement Using a Nonlinear Ultrasonic Contrast Agent
Abstract
This paper proposes a system for measuring slow, small volume blood flow, such as that found in the capillary beds. The method relies on the injection of a strongly nonlinear echocardiographic contrast agent, whose echoes are then analyzed by a modified Doppler process. The contrast agent is necessary to increase the signal-to-clutter ratio from the small blood volume, and to distinguish the blood movement from other moving structures, such as vessel walls or surrounding tissue. The nonlinear properties of this saccharide-based contrast agent are described, as evidenced by experimental evaluation. The contrast agent and signal processing modality are then tested in a blood flow simulator, at velocities as low as 1.5 mm/s, with good results. In addition, an analysis for applying this technique in vivo is presented, accounting for the dynamic and acoustic parameters of the physiological environment. Finally, some specific applications for this method are discussed, including its limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamics of Skin Microcirculation in Humans
Fagrell, B. (1985) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-198500073-00007 · Cited by 83
Cited by
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Interactions Between Microbubbles and Ultrasound: In Vitro and In Vivo Observations
Wei, K., Skyba, D. M., Firschke, C., Jayaweera, A. R., Lindner, J. R., & Kaul, S. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00029-6 · Cited by 282
Pressure dependence of subharmonic signals from contrast microbubbles
Shi, W., Forsberg, F., Raichlen, J., Needleman, L., & Goldberg, B. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00163-x · Cited by 252
Metadata
- Authors
- Schrope, B., Newhouse, V. L., & Uhlendorf, V.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1992-04
- Volume
- 14
- Issue
- 2
- Pages
- 134-158
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2016768862
- Cited by
- 185
- References
- 1
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simulated Capillary Blood Flow Measurement Using a Nonlinear Ultrasonic Contrast Agent. https://app.cochat.ai/papers/10.1177/016173469201400204
- The paper
- Schrope, B., Newhouse, V. L., & Uhlendorf, V. (1992). Simulated Capillary Blood Flow Measurement Using a Nonlinear Ultrasonic Contrast Agent. Ultrasonic Imaging. https://doi.org/10.1177/016173469201400204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.