CoChat

Comparisons of Quality of Life and Cardiac Performance After Complete Atrioventricular Junction Ablation and Atrioventricular Junction Modification in Patients With Medically Refractory Atrial Fibrillation

Open access
Lee, Shih-Huang, Chen, Shih-Ann, Tai, Ching-Tai, Chiang, Chern-En, Wen, Zu-Chi, Cheng, Jun-Jack, Ding, Yu-An, Chang, Mau-Song · 1998 · Journal of the American College of Cardiology
Cited by 136

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES This study compared the long-term effects of complete atrioventricular junction (AVJ) ablation with those of AVJ modification in patients with medically refractory atrial fibrillation (AF). BACKGROUND Comparisons between the long-term effects of AVJ ablation with those of AVJ modification in patients with medically refractory AF have not been systematically studied. METHODS Sixty patients with medically refractory AF were randomly assigned to receive complete AVJ ablation with permanent pacing or AVJ modification. Subjective perception of quality of life (QOL) was assessed by a semiquantitative questionnaire before and 1 and 6 months after ablation. Cardiac performance was evaluated by echocardiography and radionuclide angiography within 24 h (baseline) and at 1 and 6 months after ablation. RESULTS Both methods were associated with significant improvement in general QOL and a significant reduction in the frequency of major symptoms and symptoms during attacks. The frequency of hospital admission and emergency room visits and antiarrhythmic drug trials significantly decreased after ablation in both groups. However, patients after complete AVJ ablation had a significantly greater improvement in general QOL and a significantly reduced frequency of major symptoms and symptoms during attacks (including palpitation, dizziness, chest oppression, blurred vision and syncope). Left ventricular (LV) systolic function and the ability to perform activities of daily life significantly improved after ablation in patients with depressed LV function in both groups. All improvements after ablation or modification were maintained over the 6-month follow-up period. CONCLUSIONS AVJ ablation with permanent pacing, as compared with AVJ modification, had a significantly greater ability to decrease the frequency of attacks and the extent of symptoms of AF, and the patients who received this procedure were more satisfied with their general well-being.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(97)00530-5

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 136

Metadata

Authors
Lee, S.-H., Chen, S.-A., Tai, C.-T., Chiang, C.-E., Wen, Z.-C., Cheng, J.-J., Ding, Y.-A., & Chang, M.-S.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1998-03
Volume
31
Issue
3
Pages
637-644
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2049340699
Cited by
136
References
1
FWCI
11.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparisons of Quality of Life and Cardiac Performance After Complete Atrioventricular Junction Ablation and Atrioventricular Junction Modification in Patients With Medically Refractory Atrial Fibrillation. https://app.cochat.ai/papers/10.1016/s0735-1097(97)00530-5
The paper
Lee, S.-H., Chen, S.-A., Tai, C.-T., Chiang, C.-E., Wen, Z.-C., Cheng, J.-J., Ding, Y.-A., & Chang, M.-S. (1998). Comparisons of Quality of Life and Cardiac Performance After Complete Atrioventricular Junction Ablation and Atrioventricular Junction Modification in Patients With Medically Refractory Atrial Fibrillation. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(97)00530-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.