The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Coronary collateral quantitation in patients with coronary artery disease using intravascular flow velocity or pressure measurements
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery Stenoses
Pijls, N. H. J., de Bruyne, B., Peels, K., van der Voort, P. H., Bonnier, H. J. R. M., Bartunek, J., & Koolen, J. J. (1996) · New England Journal of Medicine · doi:10.1056/nejm199606273342604 · Cited by 2,321
Pijls, N. H., van Son, J. A., Kirkeeide, R. L., De Bruyne, B., & Gould, K. L. (1993) · Circulation · doi:10.1161/01.cir.87.4.1354 · Cited by 1,183
Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity.
Doucette, J. W., Corl, P. D., Payne, H. M., Flynn, A. E., Goto, M., Nassi, M., & Segal, J. (1992) · Circulation · doi:10.1161/01.cir.85.5.1899 · Cited by 1,016
Effects of adenosine on human coronary arterial circulation.
Wilson, R. F., Wyche, K., Christensen, B. V., Zimmer, S., & Laxson, D. D. (1990) · Circulation · doi:10.1161/01.cir.82.5.1595 · Cited by 906
Habib, G. B., Heibig, J., Forman, S. A., Brown, B. G., Roberts, R., Terrin, M. L., & Bolli, R. (1991) · Circulation · doi:10.1161/01.cir.83.3.739 · Cited by 429
Bruyne, B. D., Bartúnek, J., Sys, S. U., & Heyndrickx, G. R. (1995) · Circulation · doi:10.1161/01.cir.92.1.39 · Cited by 307
Coronary collateral development in swine after coronary artery occlusion.
White, F. C., Carroll, S. M., Magnet, A., & Bloor, C. M. (1992) · Circulation Research · doi:10.1161/01.res.71.6.1490 · Cited by 213
Collateral Circulation: Heart, Brain, Kidney, Limbs
Schaper, W. K. A., & Schaper, J. (2012) · Cited by 86
Cited by
Prepared by: British Cardiac Society, B. H. S. (2005) · Heart · doi:10.1136/hrt.2005.079988 · Cited by 1,216
Seiler, C., Pohl, T., Wustmann, K., Hutter, D., Nicolet, P.-A., Windecker, S., Eberli, F. R., & Meier, B. (2001) · Circulation · doi:10.1161/hc4201.097835 · Cited by 324
Self-citationThe impact of the coronary collateral circulation on mortality: a meta-analysis
Meier, P., Hemingway, H., Lansky, A. J., Knapp, G., Pitt, B., & Seiler, C. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr308 · Cited by 294
Self-citation
Metadata
- Authors
- Seiler, C., Fleisch, M., Garachemani, A., & Meier, B.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1998-11
- Volume
- 32
- Issue
- 5
- Pages
- 1272-1279
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W1965485247
- Cited by
- 255
- References
- 10
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary collateral quantitation in patients with coronary artery disease using intravascular flow velocity or pressure measurements. https://app.cochat.ai/papers/10.1016/s0735-1097(98)00384-2
- The paper
- Seiler, C., Fleisch, M., Garachemani, A., & Meier, B. (1998). Coronary collateral quantitation in patients with coronary artery disease using intravascular flow velocity or pressure measurements. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(98)00384-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.