Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,183

The DOI matches its Crossref record.

Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty.

Pijls, N H, van Son, J A, Kirkeeide, R L, De Bruyne, B, Gould, K L·1993·Circulation

Abstract

BACKGROUND: Severity of coronary artery stenosis has been defined in terms of geometric dimensions, pressure gradient-flow relations, resistance to flow and coronary flow reserve, or maximum flow capacity after maximum arteriolar vasodilation. A direct relation between coronary pressure and flow, however, may only be presumed if the resistances in the coronary circulation are constant (and minimal) as theoretically is the case during maximum arteriolar vasodilation. In that case, pressure measurements theoretically can be used to predict maximum flow and assess functional stenosis severity. METHODS AND RESULTS: A theoretical model was developed for the different components of the coronary circulation, and a set of equations was derived by which the relative maximum flow or fractional flow reserve in both the stenotic epicardial artery and the myocardial vascular bed and the proportional contribution of coronary arterial and collateral flow to myocardial blood flow are calculated from measurements of arterial, distal coronary, and central venous pressures during maximum arteriolar vasodilation. To test this model, five dogs were acutely instrumented with an epicardial, coronary Doppler flow velocity transducer. Distal coronary pressures were measured by an ultrathin pressure-monitoring guide wire (0.015 in.) with minimal influence on transstenotic pressure gradient. Fractional flow reserve was calculated from the pressure measurements and compared with relative maximum coronary artery flow measured directly by the Doppler flowmeter at three different levels of arterial pressure for each of 12 different severities of stenosis at each pressure level. Relative maximum blood flow through the stenotic artery (Qs) measured directly by the Doppler flowmeter showed an excellent correlation with the pressure-derived values of Qs (r = 0.98 +/- 0.01, intercept = 0.02 +/- 0.03, slope = 0.98 +/- 0.04), of the relative maximum myocardial flow (r = 0.98 +/- 0.02, intercept = 0.26 +/- 0.07, slope = 0.73 +/- 0.08), and of the collateral blood flow (r = 0.96 +/- 0.04, intercept = 0.24 +/- 0.07, slope = -0.24 +/- 0.06). Moreover, the theoretically predicted constant relation between mean arterial pressure and coronary wedge pressure, both corrected for venous pressure, was confirmed experimentally (r = 0.97 +/- 0.03, intercept = 9.5 +/- 13.3, slope = 4.4 +/- 1.2). CONCLUSIONS: These results provide the experimental basis for determining relative maximum flow or fractional flow reserve of both the epicardial coronary artery and the myocardium, including collateral flow, from pressure measurements during maximum arteriolar vasodilation. With a suitable guide wire for reliably measuring distal coronary pressure clinically, this method may have potential applications during percutaneous transluminal coronary angioplasty for assessing changes in the functional severity of coronary artery stenoses and for estimating collateral flow achievable during occlusion of the coronary artery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.87.4.1354

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,183

Metadata

Authors
Pijls, N. H., van Son, J. A., Kirkeeide, R. L., De Bruyne, B., & Gould, K. L.
Venue
Circulation
Published
1993-04
Volume
87
Issue
4
Pages
1354-1367
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2001110351
Cited by
1,183
References
0
FWCI
12.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty. https://app.cochat.ai/papers/10.1161/01.cir.87.4.1354
The paper
Pijls, N. H., van Son, J. A., Kirkeeide, R. L., De Bruyne, B., & Gould, K. L. (1993). Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty. Circulation. https://doi.org/10.1161/01.cir.87.4.1354

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.