Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Long-term outcome of patients with drug-refractory atrial flutter and fibrillation after single- and dual-site right atrial pacing for arrhythmia prevention

Open access
Delfaut, Philippe, Saksena, Sanjeev, Prakash, Atul, Krol, Ryszard B. · 1998 · Journal of the American College of Cardiology

Abstract

OBJECTIVES An initial crossover study comparing dual- and single-site right atrial pacing was performed followed by a long-term efficacy and safety evaluation of dual-site right atrial pacing in patients with drug-refractory atrial fibrillation (AF). Also examined was the efficacy of two single-site right atrial pacing modes (high right atrium and coronary sinus ostium) and the long-term need for cardioversion, antithrombotic and antiarrhythmic drug therapies during dual-site atrial pacing. METHODS Thirty consecutive patients with drug-refractory symptomatic AF and documented primary or drug-induced bradycardia were implanted with a dual chamber rate-responsive pacemaker and two atrial leads. Single-site atrial pacing was performed at the high right atrium or the coronary sinus ostium. Continuous atrial pacing was maintained. RESULTS Mean arrhythmia-free intervals increased from 9+/-10 days in the control period preceding implant to 143+/-110 days (p < 0.0001) in single-site right atrial pacing and 195+/-96 days in dual-site right atrial pacing (p < 0.005 versus single-site pacing and p < 0.0001 versus control). Dual-site right atrial pacing significantly increased the proportion of patients free of AF recurrence (89%) as compared to single-site right atrial pacing (62%, p = 0.02). High right atrial pacing and coronary sinus ostial pacing had similar efficacy for AF prevention. Effective rhythm control was achieved in 86% of patients during dual right atrial pacing. Seventy-eight percent of patients at 1 year and 56% at 3 years remained free of symptomatic AF. The need for cardioversion was reduced after pacemaker implant (p < 0.05) and antithrombotic therapy was reduced (p < 0.06) without any thromboembolic event. Coronary sinus ostial lead dislodgement was not observed after discharge. CONCLUSIONS Atrial pacing in combination with antiarrhythmic drugs eliminates or markedly reduces recurrent AF. Prevention of AF is enhanced by dual-site right atrial pacing. High right atrial and coronary sinus ostial pacing do not differ in efficacy. Dual-site right atrial pacing is safe, achieves long-term rhythm control in most patients, decreases the need for cardioversion, and antithrombotic therapy can be selectively reduced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(98)00489-6

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 225

Metadata

Authors
Delfaut, P., Saksena, S., Prakash, A., & Krol, R. B.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1998-12
Volume
32
Issue
7
Pages
1900-1908
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2031272406
Cited by
225
References
1
FWCI
19.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-term outcome of patients with drug-refractory atrial flutter and fibrillation after single- and dual-site right atrial pacing for arrhythmia prevention. https://app.cochat.ai/papers/10.1016/s0735-1097(98)00489-6
The paper
Delfaut, P., Saksena, S., Prakash, A., & Krol, R. B. (1998). Long-term outcome of patients with drug-refractory atrial flutter and fibrillation after single- and dual-site right atrial pacing for arrhythmia prevention. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(98)00489-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.