Cited by 101Cardiac pacing and defibrillation studiesCardiac electrophysiology and arrhythmiasCardiac Arrhythmias and Treatments

Sudden death in implantable cardioverter-defibrillator recipients: clinical context, arrhythmic events and device responses

Open access
Pires, Luis A., Lehmann, Michael H., Steinman, Russell T., Baga, John J., Schuger, Claudio D.·1999·Journal of the American College of Cardiology

Abstract

Objectives We sought to investigate the nature of terminal events and potential contributory clinical and nonclinical (e.g., device-related) factors associated with sudden death (SD) in recipients of an implantable cardioverter-defibrillator (ICD).Background The ICD is very effective in terminating ventricular tachycardia (VT) or ventricular fibrillation (VF), but protection against SD is not absolute. Little is known about the nature and potential causes of SD in patients with ICDs.Methods We analyzed 25 cases of out-of-hospital SD among patients enrolled in the clinical investigation of the Cadence Tiered-Therapy Defibrillator System.Results All patients (24 men and 1 woman, mean age 62+/-10 years) received epicardial lead systems. The majority (92%) had coronary artery disease and a previous myocardial infarction (MI), with a mean left ventricular ejection fraction 0.25+/-0.07. At device implantation, the mean defibrillation threshold was 13+/-5 J. Sudden death occurred 13+/-11 months later. Twenty patients (80%) had received appropriate ICD therapies before death, and 18 (72%) were receiving > or = 1 antiarrhythmic drugs at the time of death. Sudden death was tachyarrhythmia-associated in 16 patients (64%), non-tachyarrhythmia-associated in 7 (28%) and indeterminate in 2 (8%). In the 16 patients with tachyarrhythmia-associated SD, the overall first therapy success rate in tachycardia and fibrillation zones was 60% and 67%, respectively. However, despite protracted therapies (> or = 2 shocks) in 7 (66%) of 12 patients who received fibrillation therapies, the final tachyarrhythmic episode was ultimately terminated by the ICD in 15 (94%) of the 16 patients, whereas 1 patient died after multiple (initially successful) internal and external shocks for intractable VT/VF during exercise. In 10 patients (40%) one or more, primarily clinical, factors potentially contributory to SD were identified: heart failure (n=8), angina (n=2), hypokalemia (n=1), adverse antiarrhythmic drug treatment (n=1) and acute MI (n=1). An additional 10 patients (40%) had experienced an increase in frequency of ICD shocks within 3 months of SD. Appropriate battery voltages and normal circuitry function were found in all devices interrogated and analyzed after death.Conclusions In this select group of patients receiving a third-generation ICD, SD was associated with VT or VF events in nearly two-thirds of patients, and death occurred despite ultimately successful, although often protracted, device therapies. These observations, along with evidence of recent worsening clinical status, suggest acute cardiac mechanical dysfunction as a frequent terminal factor. In recipients with ICDs, SD directly attributable to device failure seems to be rare.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(98)00519-1

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Only 2 cases of shock failure during exercise, both on a treadmill, have been reported; one of which had a known Ethmozine-induced increase in defibrillation threshold and the other following very heavy alcohol ingestion.

    “However, only 2 cases of shock failure during exercise, both on a treadmill, have been reported; one of which had a known Ethmozine-induced increase in defibrillation threshold 104 and the other following very heavy alcohol ingestion.105”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Bayes de Luna AB, Coumel P, Leclercq JF. Ambulatory sudden cardiac death: mechanisms of production of fatal arrhythmia. Am Heart J 1989;117: 151-9.

Cited by

Sorted by citations

Authors
Pires, L. A., Lehmann, M. H., Steinman, R. T., Baga, J. J., & Schuger, C. D.
Affiliations
Wayne State University (US)
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1999-01
Volume
33
Issue
1
Pages
24-32
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2052429583
Cited by
101
References
37
Citations by year
2025: 1 · 2024: 4 · 2023: 4 · 2022: 1 · 2021: 4 · 2019: 7 · 2018: 3 · 2017: 2 · 2016: 4 · 2015: 3 · 2014: 2 · 2013: 7 · 2012: 5
FWCI
4.31
Type
journal article
Language
en
Open access
Locations
  • Journal of the American College of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Massachusetts General Hospital
  • University of Pennsylvania
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
Keywords
sudden death, implantable cardioverter-defibrillator, ventricular tachycardia, ventricular fibrillation, antiarrhythmic drugs, heart failure, coronary artery disease, myocardial infarction, hypokalemia, defibrillation threshold, epicardial leads
MeSH terms
Adult, Aged, Cause of Death, Female, Follow-Up Studies, Humans, Male, Middle Aged, Risk Factors, Ventricular Fibrillation, Exercise, Death, Sudden, Cardiac, Defibrillators, Implantable, Tachycardia, Ventricular, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review