In situ cell nucleus deformation in tendons under tensile load; a morphological analysis using confocal laser microscopy
Open accessThe DOI matches its Crossref record.
Abstract
Cell and cell nucleus deformations have been implicated in the mechanotransduction of mechanical loads acting on tissues. While in situ cell nucleus deformation in response to increasing tissue strains has been examined in articular cartilage this phenomenon has not been investigated in tendons. To examine in situ cell nuclei deformation in tendons undergoing tensile strain rat tail tendons were harvested from adult Sprague–Dawley rats and stained with acridine orange to highlight the cell nuclei. The tendons were mounted on a custom‐designed, low‐load, tensile testing device affixed to the mechanical stage of a confocal laser microscope. Cells within the tendons were isolated for analysis. Images of individual cells were captured at 0% strain as well as sequentially at 2%, 4% and 6% grip‐to‐grip tendon strain. Digital images of the cell nuclei were then measured in the x (length) and y (height) axis and deformation expressed as a percentage of cell nuclei strain. In addition, centroid‐to‐centroid distances of adjacent cell nuclei within each image were measured and used to calculate local tissue strain. There was a weak (r2 = 0.34) but significant (p < 0.01) correlation between local tissue strain and cell nucleus strain in the x axis. The results of this study support the hypothesis that in situ cell nucleus deformation does occur during tensile loading of tendons. This deformation may play a significant role in the mechanical signal transduction pathway of this tissue. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Role of Extracellular Matrix in Adaptation of Tendon and Skeletal Muscle to Mechanical Loading
KJÆR, M. (2004) · Physiological Reviews · doi:10.1152/physrev.00031.2003 · Cited by 1,586
The pathogenesis of tendinopathy: balancing the response to loading
Magnusson, S. P., Langberg, H., & Kjaer, M. (2010) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2010.43 · Cited by 498
Snedeker, J. G., & Foolen, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.08.032 · Cited by 377
Rees, J. D., Maffulli, N., & Cook, J. (2009) · The American Journal of Sports Medicine · doi:10.1177/0363546508324283 · Cited by 361
Provenzano, P. P., & Vanderby, R. (2006) · Matrix Biology · doi:10.1016/j.matbio.2005.09.005 · Cited by 339
Metadata
- Authors
- Arnoczky, S. P., Lavagnino, M., Whallon, J. H., & Hoonjan, A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 20
- Issue
- 1
- Pages
- 29-35
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2037517508
- Cited by
- 143
- References
- 0
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In situ cell nucleus deformation in tendons under tensile load; a morphological analysis using confocal laser microscopy. https://app.cochat.ai/papers/10.1016/s0736-0266(01)00080-8
- The paper
- Arnoczky, S. P., Lavagnino, M., Whallon, J. H., & Hoonjan, A. (2002). In situ cell nucleus deformation in tendons under tensile load; a morphological analysis using confocal laser microscopy. Journal of Orthopaedic Research. https://doi.org/10.1016/s0736-0266(01)00080-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.