In situ cell nucleus deformation in tendons under tensile load; a morphological analysis using confocal laser microscopy
Open accessThe DOI matches its Crossref record.
Abstract
Cell and cell nucleus deformations have been implicated in the mechanotransduction of mechanical loads acting on tissues. While in situ cell nucleus deformation in response to increasing tissue strains has been examined in articular cartilage this phenomenon has not been investigated in tendons. To examine in situ cell nuclei deformation in tendons undergoing tensile strain rat tail tendons were harvested from adult Sprague–Dawley rats and stained with acridine orange to highlight the cell nuclei. The tendons were mounted on a custom‐designed, low‐load, tensile testing device affixed to the mechanical stage of a confocal laser microscope. Cells within the tendons were isolated for analysis. Images of individual cells were captured at 0% strain as well as sequentially at 2%, 4% and 6% grip‐to‐grip tendon strain. Digital images of the cell nuclei were then measured in the x (length) and y (height) axis and deformation expressed as a percentage of cell nuclei strain. In addition, centroid‐to‐centroid distances of adjacent cell nuclei within each image were measured and used to calculate local tissue strain. There was a weak (r2 = 0.34) but significant (p < 0.01) correlation between local tissue strain and cell nucleus strain in the x axis. The results of this study support the hypothesis that in situ cell nucleus deformation does occur during tensile loading of tendons. This deformation may play a significant role in the mechanical signal transduction pathway of this tissue. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Role of Extracellular Matrix in Adaptation of Tendon and Skeletal Muscle to Mechanical Loading
KJÆR, M. (2004) · Physiological Reviews · doi:10.1152/physrev.00031.2003 · Cited by 1,586
The pathogenesis of tendinopathy: balancing the response to loading
Magnusson, S. P., Langberg, H., & Kjaer, M. (2010) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2010.43 · Cited by 498
Snedeker, J. G., & Foolen, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.08.032 · Cited by 377
Rees, J. D., Maffulli, N., & Cook, J. (2009) · The American Journal of Sports Medicine · doi:10.1177/0363546508324283 · Cited by 361
Provenzano, P. P., & Vanderby, R. (2006) · Matrix Biology · doi:10.1016/j.matbio.2005.09.005 · Cited by 339
Kong, L., Gao, Y., Lu, G., Gong, Y., Zhao, N., & Zhang, X. (2006) · European Polymer Journal · doi:10.1016/j.eurpolymj.2006.08.009 · Cited by 331
Human tendon behaviour and adaptation, in vivo
Magnusson, S. P., Narici, M. V., Maganaris, C. N., & Kjaer, M. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.139105 · Cited by 330
Arnoczky, S. P., Lavagnino, M., & Egerbacher, M. (2007) · International Journal of Experimental Pathology · doi:10.1111/j.1365-2613.2007.00548.x · Cited by 239
“Because tendon cell strain in situ has been shown to be appreciably less than whole tendon strain (Arnoczky et al. 2002), it is unlikely that such high levels of repetitive tendon cell strain could be reached and maintained in vivo without significant damage occurring within the extracellular…”
BackgroundInfluentialSelf-citationThe role of the non‐collagenous matrix in tendon function
Thorpe, C. T., Birch, H. L., Clegg, P. D., & Screen, H. R. C. (2013) · International Journal of Experimental Pathology · doi:10.1111/iep.12027 · Cited by 234
“It is well established that tendon extension occurs predominantly by sliding between adjacent fibres and fibrils, rather than by fibre/fibril extension (Arnoczky et al. 2002; Screen et al. 2004; Cheng & Screen 2007; Snedeker et al. 2009a,b; Goulam Houssen et al. 2011).”
BackgroundIn situ multi-level analysis of viscoelastic deformation mechanisms in tendon collagen
Gupta, H. S., Seto, J., Krauss, S., Boesecke, P., & Screen, H. R. C. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.10.002 · Cited by 197
“Studies have also indicated that macroscopic tissue deformation is transferred to the tenocytes (Arnoczky et al., 2002), and the local strain environment surrounding the cells, Table 1”
BackgroundArnoczky, S. P., Tian, T., Lavagnino, M., Gardner, K., Schuler, P., & Morse, P. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00038-4 · Cited by 195
Self-citationArnoczky, S. P., Tian, T., Lavagnino, M., & Gardner, K. (2004) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00185-2 · Cited by 177
“It is likely that with increasing load an increasing number of cells undergo nuclear (and presumably cytoskeletal) deformation [5].”
Self-citationLavagnino, M., Arnoczky, S. P., Tian, T., & Vaupel, Z. (2003) · Connective Tissue Research · doi:10.1080/03008200390215881 · Cited by 175
“Studies have shown that in rat tail tendons even local tissue strain is nonhomogenous throughout the depth of the tendon [33, 37].”
BackgroundInfluentialSelf-citationTendon mechanobiology: Current knowledge and future research opportunities
Lavagnino, M., Wall, M. E., Little, D., Banes, A. J., Guilak, F., & Arnoczky, S. P. (2015) · Journal of Orthopaedic Research · doi:10.1002/jor.22871 · Cited by 160
“The deformation of tendon extracellular matrix from applied loading transmits various levels and combinations of tensile and compressive, shear stresses, and strains to the tendon cells.(17) The transmission of this deformation to the localized cell or nucleus correlates to, but is less than the applied tendon deforma…”
BackgroundSelf-citationNuclear morphology and deformation in engineered cardiac myocytes and tissues
Bray, M.-A. P., Adams, W. J., Geisse, N. A., Feinberg, A. W., Sheehy, S. P., & Parker, K. K. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.028 · Cited by 107
“Concerning (3), a similar anisotropic deformation response has been observed in tendon nuclei undergoing tensile strain [42] and chondrocyte and fibroblast nuclei undergoing compression [13,43].”
Tsai, M.-S., Domroes, T., Pentidis, N., Koschinski, S., Schroll, A., Bohm, S., Arampatzis, A., & Mersmann, F. (2024) · Scientific Reports · doi:10.1038/s41598-024-56840-6 · Cited by 12
Metadata
- Authors
- Arnoczky, S. P., Lavagnino, M., Whallon, J. H., & Hoonjan, A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 20
- Issue
- 1
- Pages
- 29-35
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2037517508
- Cited by
- 143
- References
- 0
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.