Anisotropic properties of human tibial cortical bone as measured by nanoindentation
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to investigate the effects of elastic anisotropy on nanoindentation measurements in human tibial cortical bone. Nanoindentation was conducted in 12 different directions in three principal planes for both osteonic and interstitial lamellae. The experimental indentation modulus was found to vary with indentation direction and showed obvious anisotropy (oneway analysis of variance test, P < 0.0001). Because experimental indentation modulus in a specific direction is determined by all of the elastic constants of cortical bone, a complex theoretical model is required to analyze the experimental results. A recently developed analysis of indentation for the properties of anisotropic materials was used to quantitatively predict indentation modulus by using the stiffness matrix of human tibial cortical bone, which was obtained from previous ultrasound studies. After allowing for the effects of specimen preparation (dehydrated specimens in nanoindentation tests vs. moist specimens in ultrasound tests) and the structural properties of bone (different microcomponents with different mechanical properties), there were no statistically significant differences between the corrected experimental indentation modulus (Mexp) values and corresponding predicted indentation modulus (Mpre) values (two‐tailed unpaired t‐test, P < 0.5). The variation of Mpre values was found to exhibit the same trends as the corrected Mexp data. These results show that the effects of anisotropy on nanoindentation measurements can be quantitatively evaluated. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oliver, W. C., & Pharr, G. M. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.1564 · Cited by 26,961
Self-citationJohnson, K. L. (1985) · Cambridge University Press eBooks · doi:10.1017/cbo9781139171731 · Cited by 7,796
Zysset, P. K., Edward Guo, X., Edward Hoffler, C., Moore, K. E., & Goldstein, S. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00111-6 · Cited by 1,006
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Self-citationElastic analysis of some punch problems for a layered medium
King, R. B. (1987) · International Journal of Solids and Structures · doi:10.1016/0020-7683(87)90116-8 · Cited by 898
Lamellar Bone: Structure–Function Relations
Weiner, S., Traub, W., & Wagner, H. D. (1999) · Journal of Structural Biology · doi:10.1006/jsbi.1999.4107 · Cited by 674
Analysis of Berkovich indentation
Larsson, P.-L., Giannakopoulos, A. E., SÖderlund, E., Rowcliffe, D. J., & Vestergaard, R. (1996) · International Journal of Solids and Structures · doi:10.1016/0020-7683(95)00033-7 · Cited by 361
Elastic properties of microstructural components of human bone tissue as measured by nanoindentation
Rho, J.-Y., Roy, M. E., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199904)45:1<48::aid-jbm7>3.0.co;2-5 · Cited by 348
Self-citationIndentation modulus of elastically anisotropic half spaces
Vlassak, J. J., & Nix, W. D. (1993) · Philosophical Magazine A · doi:10.1080/01418619308224756 · Cited by 297
Rho, J. Y., Zioupos, P., Currey, J. D., & Pharr, G. M. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00199-3 · Cited by 276
Self-citation
Cited by
Biomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Mechanical properties of spruce wood cell walls by nanoindentation
Gindl, W., Gupta, H. S., Schöberl, T., Lichtenegger, H. C., & Fratzl, P. (2004) · Applied Physics A · doi:10.1007/s00339-004-2864-y · Cited by 268
Lewis, G., & Nyman, J. S. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31092 · Cited by 165
Structural Orientation and Anisotropy in Biological Materials: Functional Designs and Mechanics
Liu, Z., Zhang, Z., & Ritchie, R. O. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908121 · Cited by 164
Elastic Anisotropy of Human Cortical Bone Secondary Osteons Measured by Nanoindentation
Franzoso, G., & Zysset, P. K. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3005162 · Cited by 89
The estimated elastic constants for a single bone osteonal lamella
Yoon, Y. J., & Cowin, S. C. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0072-8 · Cited by 80
“Even though there aremany reports for the bonematrix elastic constants (Akiva et al. 1997, 1998; Bonfield and Li 1966; Crolet et al. 1993; Currey 1964; Fan et al. 2002; Hellmich andUlm 2002; Hellmich et al. 2004; Katz 1971; Piekarski 1973; Rho et al. 1993, 1997, 1999a,b,c, 2002; Sasaki et al. 1991; Swandener et al. 20…”
BackgroundMethodMartínez-Reina, J., Domínguez, J., & García-Aznar, J. M. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0236-4 · Cited by 61
Microscopic assessment of bone toughness using scratch tests
Kataruka, A., Mendu, K., Okeoghene, O., Puthuvelil, J., & Akono, A.-T. (2017) · Bone Reports · doi:10.1016/j.bonr.2016.12.001 · Cited by 28
“The values of the anisotropic elastic constants for bones are drawn from micro-scale studies in the scientific literature based on ultrasonic velocity measurement tests (Fritsch and Hellmich, (2007), and nano-indentation tests (Fan et al., 2002; Feng et al., 2012; Franzoso and Zysset, 2009).”
Method
Metadata
- Authors
- Fan, Z., Swadener, J. G., Rho, J. Y., Roy, M. E., & Pharr, G. M.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2002-07
- Volume
- 20
- Issue
- 4
- Pages
- 806-810
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1993744408
- Cited by
- 254
- References
- 19
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.