CoChat

Effect of pulsed electromagnetic fields (PEMF) on late‐phase osteotomy gap healing in a canine tibial model

Open access
Inoue, Nozomu, Ohnishi, Isao, Chen, Dongan, Deitz, Luke W., Schwardt, Jeffrey D., Chao, Edmund Y. S. · 2002 · Journal of Orthopaedic Research
Cited by 96

The DOI matches its Crossref record.

Abstract

The effects of a pulsed electromagnetic field (PEMF) on late bone healing phases using an osteotomy gap model in the canine mid‐tibia were investigated. A transverse mid‐diaphyseal tibial osteotomy with a 2‐mm gap was performed unilaterally in 12 adult mixed‐breed dogs and stabilized with external fixation. Animals in the variable group (n = 6) were treated with PEMF for 1 h daily starting 4 weeks after surgery for a total of 8 weeks, whereas no stimulation signal was generated in the control group (n = 6). Functional load‐bearing and radiographic assessments were conducted time‐sequentially until euthanasia 12 weeks after surgery. Torsional tests and an analysis of undecalcified histology were performed on the retrieved mid‐tibial diaphysis containing the osteotomy site. In the PEMF group, load‐bearing of the operated limb recovered earlier when compared to the control group (p < 0.05). Load‐bearing in the PEMF group at 8 weeks was greater than in the control group (p < 0.02). The periosteal callus area increased following surgery at 6 weeks (p < 0.05) and thereafter (p < 0.01) in the PEMF group, while a significant increase was observed at 8 and 10 weeks after surgery (p < 0.05) in the control group. Both the normalized maximum torque and torsional stiffness of the PEMF group were significantly greater than those of the control group (p < 0.04 and p < 0.007, respectively). Histomorphometric analyses revealed greater new‐bone formation (p < 0.05) in the osteotomy gap tissue and increased mineral apposition rate (p < 0.04) and decreased porosity in the cortex adjacent to the osteotomy line (p < 0.02) in the PEMF group. PEMF stimulation of 1 h per day for 8 weeks provided faster recovery of load‐bearing, a significant increase in new bone formation, and a higher mechanical strength of the healing mid‐tibial osteotomy. This study revealed enhancing effects of PEMF on callus formation and maturation in the late‐phase of bone healing. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0736-0266(02)00031-1

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 96

Metadata

Authors
Inoue, N., Ohnishi, I., Chen, D., Deitz, L. W., Schwardt, J. D., & Chao, E. Y. S.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
2002-09
Volume
20
Issue
5
Pages
1106-1114
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2047904767
Cited by
96
References
0
FWCI
3.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of pulsed electromagnetic fields (PEMF) on late‐phase osteotomy gap healing in a canine tibial model. https://app.cochat.ai/papers/10.1016/s0736-0266(02)00031-1
The paper
Inoue, N., Ohnishi, I., Chen, D., Deitz, L. W., Schwardt, J. D., & Chao, E. Y. S. (2002). Effect of pulsed electromagnetic fields (PEMF) on late‐phase osteotomy gap healing in a canine tibial model. Journal of Orthopaedic Research. https://doi.org/10.1016/s0736-0266(02)00031-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.