Single- versus bi-socket anterior cruciate ligament reconstruction using autogenous multiple-stranded hamstring tendons with EndoButton femoral fixation
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
PURPOSE: This prospective study was conducted to compare the single-socket and the bi-socket anterior cruciate ligament (ACL) reconstruction techniques in terms of outcome. TYPE OF STUDY: Nonrandomized control trial. METHODS: There were 160 consecutive patients with unilateral chronic ACL insufficiency who underwent endoscopic single- or bi-socket ACL reconstruction alternately using multiple-stranded medial hamstring tendon and EndoButton (Smith & Nephew, Andover, MD) femoral fixation. All patients underwent the same postoperative rehabilitation protocol. Of them, 106 patients (57 single, 49 bi) were available for 2-year follow-up. RESULTS: According to the IKDC Knee Ligament Evaluation Form, 23 patients (40%) of the single-socket group were subjectively graded as normal, 30 (53%) as nearly normal, and 4 (7%) as abnormal. Twenty-six patients (53%) of the bi-socket group were graded as normal, 21 (43%) as nearly normal, and 2 (4%) as abnormal (P =.19). The mean side-to-side anterior laxity difference (KT-1000 manual maximum force) was 0.9 +/- 1.8 mm for the single-socket group and 0.7 +/- 1.2 mm for the bi-socket group (P =.44). Fifty-three of 57 patients (93%) in the single-socket group and all patients in the bi-socket group showed anterior laxity differences of +/-3 mm or less (P =.12). There were no differences in thigh muscle strength between the groups. CONCLUSIONS: Both single- and bi-socket ACL reconstruction using autogenous multiple-stranded hamstring tendons with EndoButton fixation provided satisfactory anterior stability, and there were no statistically significant differences in subjective results or measured restored stability between the 2 groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of knee ligament injuries with the IKDC form
Hefti, F., Müller, W., Jakob, R. P., & Stäubli, H. ‐. (1993) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/bf01560215 · Cited by 1,569
The Cruciate Ligaments of the Knee Joint: Anatomical. Functional and Experimental Analysis
Girgis, F. G., Marshall, J. L., & MONA JEM, A. R. S. A. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197501000-00033 · Cited by 1,485
Functional anatomy of the anterior cruciate ligament and a rationale for reconstruction.
Odensten, M., & Gillquist, J. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567020-00012 · Cited by 614
Anatomy of the Anterior Cruciate Ligament
ARNOCZKY, S. P. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198301000-00006 · Cited by 558
Marder, R. A., Raskind, J. R., & Carroll, M. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900510 · Cited by 508
Quantitative Analysis of Human Cruciate Ligament Insertions
Harner, C. D., Baek, G. H., Vogrin, T. M., Carlin, G. J., Kashiwaguchi, S., & Woo, S. L.-Y. (1999) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(99)70006-x · Cited by 502
Muneta, T., Sekiya, I., Yagishita, K., Ogiuchi, T., Yamamoto, H., & Shinomiya, K. (1999) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/ar.1999.v15.0150611 · Cited by 349
Anterior Cruciate Ligament Reconstruction with Multistranded Autogenous Semitendinosus Tendon
Maeda, A., Shino, K., Horibe, S., Nakata, K., & Buccafusca, G. (1996) · The American Journal of Sports Medicine · doi:10.1177/036354659602400416 · Cited by 274
Self-citationHOWELL, L. C. S. M., & TAYLOR, C. M. A. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199606000-00003 · Cited by 232
Hamada, M., Shino, K., Horibe, S., Mitsuoka, T., Miyama, T., & Toritsuka, Y. (2000) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1053/jars.2000.5876 · Cited by 28
Self-citation
Cited by
Treatment of Anterior Cruciate Ligament Injuries, Part I
Beynnon, B. D., Johnson, R. J., Abate, J. A., Fleming, B. C., & Nichols, C. E. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546505279913 · Cited by 638
Yasuda, K., Kondo, E., Ichiyama, H., Kitamura, N., Tanabe, Y., Tohyama, H., & Minami, A. (2004) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2004.08.010 · Cited by 554
Yasuda, K., Kondo, E., Ichiyama, H., Tanabe, Y., & Tohyama, H. (2006) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2005.12.017 · Cited by 498
Kvist, J. (2004) · Sports Medicine · doi:10.2165/00007256-200434040-00006 · Cited by 460
Colombet, P., Robinson, J., Christel, P., Franceschi, J.-P., Djian, P., Bellier, G., & Sbihi, A. (2006) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2006.04.102 · Cited by 426
Metadata
- Authors
- Hamada, M., Shino, K., Horibe, S., Mitsuoka, T., Miyama, T., Shiozaki, Y., & Mae, T.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2001-10
- Volume
- 17
- Issue
- 8
- Pages
- 801-807
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W1524584804
- Cited by
- 233
- References
- 10
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.